Development of a flow control valve with digital flow compensator

被引:22
|
作者
Huang, Jiahai [1 ,2 ]
Wang, Xiaona [2 ]
Wang, Hao [2 ]
Hao, Huimin [1 ,2 ]
机构
[1] Taiyuan Univ Technol, Minist Educ & Shanxi Prov, Key Lab Adv Transducers & Intelligent Control Sys, Taiyuan 030024, Shanxi, Peoples R China
[2] Taiyuan Univ Technol, Coll Mech & Vehicle Engn, Taiyuan 030024, Shanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow control valve; Pressure drop; Flow measurement; Digital flow compensator;
D O I
10.1016/j.flowmeasinst.2019.03.004
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Flow control valves typically use mechanical pressure drop compensator or dynamic flow meter to lessen the impact of pressure drop on outlet flow. However, there are some disadvantages, such as complex mechanical structure and small flow capacity. In this paper, a kind of digital flow compensator with bilinear interpolation algorithm is presented to compensate the pressure drop, in which the pressure drop and the desired outlet flow are the two input parameters. A two-stage proportional flow control valve with the proposed compensator is investigated. Pressure drop across the metering orifice of the valve is measured and fed back to the proposed compensator. If the detected pressure drop has deviated from the threshold, then the compensator will generate a compensation signal to adjust the poppet opening of the valve, which ensures that the output flow is independent of the pressure drop. Performances of the valve with the proposed compensator are investigated by simulation and experiment. Results show that it has a reasonable static control characteristics. In addition, there is no dead-zone in its steady flow curve; pressure drop have little impact on its output flow. Its dynamics will be affected by pressure drop and input voltage. Increasing pressure drop can improve system dynamics under constant input signal conditions. On the other hand, increasing input signal can shorten the poppet's closing time, but it will result in the longer opening time and the greater overshoot in the opening stage.
引用
收藏
页码:157 / 169
页数:13
相关论文
共 50 条
  • [31] ADJUSTABLE FLOW-CONTROL VALVE FOR THE SELF-ENERGISING ELECTRO-HYDRAULIC BRAKE
    Kuehnlein, Michael
    Liermann, Matthias
    Ewald, Julian
    Murrenhoff, Hubertus
    INTERNATIONAL JOURNAL OF FLUID POWER, 2012, 13 (02) : 5 - 14
  • [32] A study on flow control valve characteristics in an oil hydraulic vane pump for power steering systems
    Cho, Ihn Sung
    Jung, Jae Youn
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (06) : 2357 - 2363
  • [33] Pressure drop in air/kerosene two-phase flow in horizontal pipe and control valve
    Malini, RH
    Partheeban, P
    Sundaram, S
    ISA 2002 TECHNOLOGY UPDATE, VOL LVII, PT 1, 2002, 422 : 788 - 802
  • [34] Advanced flow measurement and active flow control of aircraft with MEMS
    Jiang Chengyu
    EngineeringSciences, 2012, 10 (05) : 26 - 32
  • [35] Reliability analysis of a novel pulse code modulation flow control valve with self-compensating ability
    Zhang Peng
    Gao Jinji
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2007, 23 (04) : 431 - 444
  • [36] Analysis of flow torques during opening and closing of high-frequency rotary directional control valve
    Jia, Wenang
    Ni, Zifan
    Li, Zhanshang
    Li, Sheng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2023, 89
  • [37] Simulated Design of a Flow Control Valve for Stroke Speed Adjustment of Hydraulic Power of Robotic Lifting Device
    Adeoye, A. O. M.
    Aderoba, A. A.
    Oladapo, B. I.
    PLASTICITY AND IMPACT MECHANICS, 2017, 173 : 1499 - 1506
  • [38] DEVELOPMENT AND IMPLEMENTATION OF FLOW COMPUTERS
    Barajas Herrera, Edgar Javier
    Cesar Perez, Julio
    Guillermo Barrero, Jaime
    Roncansio, Rafael
    Luque Ortiz, Isaac
    FUENTES EL REVENTION ENERGETICO, 2006, 4 (01): : 7 - 15
  • [39] Flow Measurement With Digital Correlator Realized By FPGA
    Wang, Yanlong
    Zhang, Junhua
    Bu, Lulu
    Yang, Jun
    Shi, Xinling
    MATERIAL SCIENCE AND ENGINEERING TECHNOLOGY, 2012, 462 : 641 - 646
  • [40] Predictions and observations of the flow field induced by laminar flow control microperforations
    MacManus, DG
    Eaton, JA
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1996, 13 (04) : 395 - 407