Automated event detection algorithms in pathological gait

被引:57
作者
Bruening, Dustin A. [1 ,2 ]
Ridge, Sarah Trager [3 ]
机构
[1] Shriners Hosp Children, Erie, PA USA
[2] Wright Patterson Air Force Base, Dayton, OH USA
[3] Brigham Young Univ, Provo, UT 84602 USA
关键词
Instrumented gait analysis; Gait cycle; Gait classification or pattern; Event detection; Automation; KINEMATIC DATA; FOOT; CONTACT; WALKING; REPEATABILITY; CHILDREN; MODEL;
D O I
10.1016/j.gaitpost.2013.08.023
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Accurate automated event detection is important in increasing the efficiency and utility of instrumented gait analysis. Published automated event detection algorithms, however, have had limited testing on pathological populations, particularly those where force measurements are not available or reliable. In this study we first postulated robust definitions of gait events that were subsequently used to compare kinematic based event detection algorithms across difficult pathologies. We hypothesized that algorithm accuracy would vary by gait pattern, and that accurate event detection could be accomplished by first visually classifying the gait pattern, and subsequently choosing the most appropriate algorithm. Nine published kinematic event detection algorithms were applied to an existing instrumented pediatric gait database (primarily cerebral palsy pathologies), that were categorized into 4 visually distinct gait patterns. More than 750 total events were manually rated and these events were used as a gold standard for comparison to each algorithm. Results suggested that for foot strike events, algorithm choice was dependent on whether the foot's motion in terminal swing was more horizontal or vertical. For horizontal foot motion in swing, algorithms that used horizontal position, resultant sagittal plane velocity, or horizontal acceleration signals were most robust; while for vertical foot motion, resultant sagittal velocity or vertical acceleration excelled. For toe off events, horizontal position or resultant sagittal plane velocity performed the best across all groups. We also tuned the resultant sagittal plane velocity signal to walking speed to create an algorithm that can be used for all groups and in real time. Published by Elsevier B.V.
引用
收藏
页码:472 / 477
页数:6
相关论文
共 18 条
[1]  
[Anonymous], J BIOMECH
[2]   Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity [J].
Bruening, Dustin A. ;
Cooney, Kevin M. ;
Buczek, Frank L. .
GAIT & POSTURE, 2012, 35 (04) :529-534
[3]   A marker based kinematic method of identifying initial contact during gait suitable for use in real-time visual feedback applications [J].
De Asha, A. R. ;
Robinson, M. A. ;
Barton, G. J. .
GAIT & POSTURE, 2012, 36 (03) :650-652
[4]   Foot contact event detection using kinematic data in cerebral palsy children and normal adults gait [J].
Desailly, Eric ;
Daniel, Yepremian ;
Sardain, Philippe ;
Lacouture, Patrick .
GAIT & POSTURE, 2009, 29 (01) :76-80
[5]  
Downey C.A., 1989, OBSERVATIONAL GAIT A
[6]   Assessment and validation of a simple automated method for the detection of gait events and intervals [J].
Ghoussayni, S ;
Stevens, C ;
Durham, S ;
Ewins, D .
GAIT & POSTURE, 2004, 20 (03) :266-272
[7]   Algorithms to determine event timing during normal walking using kinematic data [J].
Hreljac, A ;
Marshall, RN .
JOURNAL OF BIOMECHANICS, 2000, 33 (06) :783-786
[8]   Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals [J].
Jasiewicz, Jan M. ;
Allum, John H. J. ;
Middleton, James W. ;
Barriskill, Andrew ;
Condie, Peter ;
Purcell, Brendan ;
Li, Raymond Che Tin .
GAIT & POSTURE, 2006, 24 (04) :502-509
[9]   Rear-foot, mid-foot and fore-foot motion during the stance phase of gait [J].
Leardini, A. ;
Benedetti, M. G. ;
Berti, L. ;
Bettinelli, D. ;
Nativo, R. ;
Giannini, S. .
GAIT & POSTURE, 2007, 25 (03) :453-462
[10]   The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking [J].
Mansfield, A ;
Lyons, GM .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (10) :879-885