ENERGY CONSUMPTION OF AN EXPERIMENTAL COLD STORAGE

被引:0
作者
Akdemir, S. [1 ]
机构
[1] Namik Kemal Univ, Tech Sci Vocat Sch, Air Conditioning & Refrigerat Programm, TR-59030 Tekirdag, Turkey
来源
BULGARIAN JOURNAL OF AGRICULTURAL SCIENCE | 2012年 / 18卷 / 06期
关键词
energy consumption; cold storage; refrigeration;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Energy consumption of an experimental cold storage Was measured for different storage temperatures. Suction temperature and pressure temperature of the compressor and working time of the compressor were determined to reach evaporator set up temperatures. Capacity of compressor, condenser, and evaporator were 10460 kJ/h, 12552 kJ/h, and 10460 kJ/h, respectively. An axial fan located back of the evaporator was used to distribute the cooled air into the cold store. An electrical heater was used to. defrost. Refrigerant was R22. The compressor suction and pressure temperatures varied between 1.8 degrees C-14 degrees C; and 37 degrees C-44 degrees C, respectively. Condenser output temperature changed from 28.8 to 45.5 degrees C. Electrical energy consumption were measured as 0.001 kWh for 5 degrees C, 4 degrees C, and 3 degrees C and 0.003 kWh for 2 degrees C, 0.006 kWh for 1 degrees C, 0.001 kWh for -1 degrees C, 0.109 kWh for -2 degrees C and 0.120 kWh for -3 degrees C. Mean energy consumption of the compressor was 0.035 kWh/degrees C for positive cold storage temperatures (from 5 degrees C to 0 degrees C) and 0.093 kWh/degrees C for negative temperatures (-1 degrees C, -2 degrees C, and -3 degrees C). Working tithe of the compressor was changed from 207 s to 25049 s for test temperatures.
引用
收藏
页码:991 / 996
页数:6
相关论文
共 14 条
  • [1] Akdemir S., 2003, J BIOL SCI, V3, P1114
  • [2] [Anonymous], B IIR
  • [3] [Anonymous], 2009, IMPROVING ENERGY EFF
  • [4] [Anonymous], 1999, COLD STORAGE REFRIGE
  • [5] Experimental development of an intelligent refrigeration system
    Buzelin, LOS
    Amico, SC
    Vargas, JVC
    Parise, JAR
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02): : 165 - 175
  • [6] Caglar S., 2002, THESIS KAFKAS U
  • [7] Evans J., 2009, REV AVAILABLE INFORM
  • [8] Temperature and energy performance of refrigerated retail display and commercial catering cabinets under test conditions
    Evans, J. A.
    Scarcelli, S.
    Swain, M. V. L.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (03): : 398 - 408
  • [9] Fumo N., 2003, APPL ENERG, V87, P2023
  • [10] Huan Z., 2008, Energy saving opportunities in food 'cold chain'