Light emitting diodes as an excitation source for biomedical photoacoustics

被引:15
作者
Allen, T. J. [1 ]
Beard, P. C. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013 | 2013年 / 8581卷
基金
英国工程与自然科学研究理事会;
关键词
High power LEDs; laser diodes; photoacoustic excitation sources; CODED EXCITATION; IN-VIVO; LASER-DIODE; GOLAY CODES; MICROSCOPY; RESOLUTION; SYSTEM;
D O I
10.1117/12.2004471
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Semiconductor light sources, such as laser diodes or light emitting diodes (LEDs) could provide an inexpensive and compact alternative to traditional Q-switched lasers for photoacoustic imaging. So far, only laser diodes(1-3) operating in the 750 to 905nm wavelength range have been investigated for this purpose. However, operating in the visible wavelength range (400nm to 650nm) where blood is strongly absorbent (> 10cm(-1)) and water absorption is weak (< 0.01cm(-1)) could allow for high contrast photoacoustic images of the superficial vasculature to be achieved. High power laser diodes (> 10Watt peak power) are however not available in this wavelength range. High power LEDs could be a potential alternative as they are widely available in the visible wavelength range (400nm to 632nm) and relatively cheap. High power LEDs are generally operated in continuous wave mode and provide average powers of several Watts. The possibility of over driving them by tens of times their rated current when driven at a low duty cycle (< 1%), offers the prospect of achieving similar pulse energies (tens of mu J) to that provided by high peak power pulsed laser diodes. To demonstrate the possibility of using high power LEDs as an excitation source for biomedical applications, single point measurements were implemented in a realistic blood vessel phantom. A four colour device was also used to demonstrate the possibility of using LEDs for making spectroscopic measurements. It was shown that when driving all four wavelengths at once, the generated photoacoustic signal could be used to design a filter in order to improve the SNR of the photoacoustic signals generated at each individual wavelength. The possibility of acquiring multiwavelength data sets simultaneously when using Golay excitation methods was also demonstrated. This preliminary study demonstrated the potential for using high power LEDs as an inexpensive and compact excitation source for biomedical photoacoustics.
引用
收藏
页数:9
相关论文
共 14 条
  • [1] Allen T. J., 2007, P SPIE, V6437
  • [2] Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging
    Allen, Thomas J.
    Beard, Paul C.
    [J]. OPTICS LETTERS, 2006, 31 (23) : 3462 - 3464
  • [3] Biomedical photoacoustic imaging
    Beard, Paul
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 602 - 631
  • [4] Coded excitation for diagnostic ultrasound: A system developer's perspective
    Chiao, RY
    Hao, XH
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 160 - 170
  • [5] In vivo photoacoustic imaging of blood vessels with a pulsed laser diode
    Kolkman, Roy G. M.
    Steenbergen, Wiendelt
    van Leeuwen, Ton G.
    [J]. LASERS IN MEDICAL SCIENCE, 2006, 21 (03) : 134 - 139
  • [6] Maslov K., 2005, J BIOMEDICAL OPTICS, V13
  • [7] Experimental Evaluation of Photoacoustic Coded Excitation Using Unipolar Golay Codes
    Mienkina, Martin P.
    Friedrich, Claus-Stefan
    Gerhardt, Nils C.
    Wilkening, Wilko G.
    Hofmann, Martin R.
    Schmitz, Georg
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (07) : 1583 - 1593
  • [8] Multispectral photoacoustic coded excitation imaging using unipolar orthogonal Golay codes
    Mienkina, Martin P.
    Friedrich, Claus-Stefan
    Gerhardt, Nils C.
    Beckmann, Martin F.
    Schiffner, Martin F.
    Hofmann, Martin R.
    Schmitz, Georg
    [J]. OPTICS EXPRESS, 2010, 18 (09): : 9076 - 9087
  • [9] Skov Hansen R., 2011, P SPIE, V7968
  • [10] Multifocal optical-resolution photoacoustic microscopy in vivo
    Song, Liang
    Maslov, Konstantin
    Wang, Lihong V.
    [J]. OPTICS LETTERS, 2011, 36 (07) : 1236 - 1238