TISSUE ABLATION ACCELERATED BY PERIPHERAL SCANNING MODE WITH HIGH-INTENSITY FOCUSED ULTRASOUND: A STUDY ON ISOLATED PORCINE LIVER PERFUSION

被引:5
作者
Bu, Rui
Yin, Li
Yang, Han
Wang, Qi
Wu, Feng
Zou, Jian Zhong
机构
[1] Chongqing Med Univ, State Key Lab Ultrasound Engn Med Chongqing, Coll Biomed Engn, Chongqing 400016, Peoples R China
[2] Minist Sci & Technol, Key Lab Ultrasound Med & Engn, Chongqing 400016, Peoples R China
关键词
High-intensity focused ultrasound; Peripheral scanning mode; Therapeutic ultrasound; Hepatocellular carcinoma; Porcine liver perfusion; Thermal dose; Hepatic vessel; Flow rate; HEPATOCELLULAR-CARCINOMA; TUMORS; THERAPY; HYPERECHO; IMAGES; HIFU; LESIONS;
D O I
10.1016/j.ultrasmedbio.2013.03.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aims of this study were to investigate the feasibility of accelerated tissue ablation using a peripheral scanning mode with high-intensity focused ultrasound (HIFU) and to explore the effect of flow rate on total energy consumption of the target tissues. Using a model of isolated porcine liver perfusion via the portal vein and hepatic artery, we conducted a scanning protocol along the periphery of the target tissues using linear-scanned HIFU to carefully adjust the varying focal depth, generator power, scanning velocity and line-by-line interval over the entire ablation range. Porcine livers were divided into four ablation groups: group 1, n = 12, with dual-vessel perfusion; group 2, n = 11, with portal vein perfusion alone; group 3, n = 10, with hepatic artery perfusion alone; and group 4, n = 11, control group with no-flow perfusion. The samples were cut open consecutively at a thickness of 3 mm, and the actual ablation ranges were calculated along the periphery of the target tissues after triphenyl tetrazolium chloride staining. Total energy consumption was calculated as the sum of the energy requirements at various focal depths in each group. On the basis of the pre-supposed scanning protocol, the peripheral region of the target tissue formed a complete coagulation necrosis barrier in each group with varying dose combinations, and the volume of the peripheral necrotic area did not differ significantly among the four groups (p > 0.05). Furthermore, total energy consumption in each group significantly decreased with the corresponding decrease in flow rate (p < 0.01). This study revealed that the complete peripheral necrosis barrier within the target tissues can defined using linear-scanned HIFU in an isolated porcine liver perfusion model. Additionally, the flow rate in the major hepatic vessels may play an important role in the use of the peripheral ablation mode, and this novel mode of ablation may enhance the therapeutic efficacy and tolerability of the treatment of large tumors using HIFU ablation. (E-mail: zoujz@haifu.com.cn) (C) 2013 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1410 / 1419
页数:10
相关论文
共 29 条
[1]   Ultrasound-induced tissue ablation: Studies on isolated, perfused porcine liver [J].
Arefiev, A ;
Prat, F ;
Chapelon, JY ;
Tavakkoli, J ;
Cathignol, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (07) :1033-1043
[2]   EFFECT OF BLOOD PERFUSION ON THE ABLATION OF LIVER PARENCHYMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND [J].
CHEN, L ;
TERHAAR, G ;
HILL, CR ;
DWORKIN, M ;
CARNOCHAN, P ;
YOUNG, H ;
BENSTED, JPM .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (11) :1661-1673
[3]   Influence of ablated tissue on the formation of high-intensity focused ultrasound lesions [J].
Chen, LL ;
terHaar, G ;
Hill, CR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :921-931
[4]  
Christensen D., 1988, Ultrasonic Bioinstrumentation
[5]   PERCUTANEOUS ABLATION THERAPY FOR HEPATOCELLULAR CARCINOMAS [J].
DAGOSTINO, HB ;
SOLINAS, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1165-1167
[6]   Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels [J].
Dasgupta, Subhashish ;
Banerjee, Rupak K. ;
Hariharan, Prasanna ;
Myers, Matthew R. .
ULTRASONICS, 2011, 51 (02) :171-180
[7]   In vivo demonstration of noninvasive thermal surgery of the liver and kidney using an ultrasonic phased array [J].
Daum, DR ;
Smith, NB ;
King, R ;
Hynynen, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (07) :1087-1098
[8]   Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma [J].
Feng, W ;
Wang, ZB ;
Chen, WZ ;
Hui, Z ;
Jin, B ;
Zou, JZ ;
Li, KQ ;
Jin, CB ;
Xie, FL ;
Su, HB .
ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (12) :1061-1069
[9]   Hyperecho in ultrasound images during high-intensity focused ultrasound ablation for hepatocellular carcinomas [J].
Fukuda, Hiroyuki ;
Numata, Kazushi ;
Nozaki, Akito ;
Kondo, Masaaki ;
Morimoto, Manabu ;
Tanaka, Katsuaki ;
Ito, Ryu ;
Ohto, Masao ;
Ishibashi, Yoshiharu ;
Oshima, Noriyoshi ;
Ito, Ayao ;
Zhu, Hui ;
Wang, Zhi-Biao .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) :E571-E575
[10]   Thermal ablation therapy for focal malignancy: A unified approach to underlying principles, techniques, and diagnostic imaging guidance [J].
Goldberg, SN ;
Gazelle, GS ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :323-331