Prediction of the fracture load of whole proximal femur specimens by topological analysis of the mineral distribution in DXA-scan images

被引:21
作者
Boehm, Holger F. [1 ]
Horng, Annie [1 ]
Notohamiprodjo, Mike [1 ]
Eckstein, Felix [3 ]
Burklein, Dominik [2 ]
Panteleon, Alexandra [1 ]
Lutz, Juergen [1 ]
Reiser, Maximilian [1 ]
机构
[1] Univ Munich, Dept Radiol, D-80336 Munich, Germany
[2] Univ Munich, Dept Trauma Surg, D-80336 Munich, Germany
[3] Paracelsus Private Med Univ, Inst Anat & Musculoskeletal Res, Salzburg, Austria
关键词
Bone mineral distribution; Topology; DXA; Mechanical strength; In vitro; Nominal femur;
D O I
10.1016/j.bone.2008.07.244
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate scanner-generated images of hip specimens obtained from dual energy X-ray absorptiometry (DXA) by quantitative image analysis of bone mineral distribution in the standard regions of interest (ROI), to predict the ultimate mechanical strength, and to compare the predictive potential with standard densitometry. Materials and Methods: Femoral bone mineral density (BMD) of 100 hip specimens was obtained by DXA in the total hip, shaft, trochanteric, and neck ROI Maximum compressive strength (MCS) of the specimens was measured in a mechanical loading device simulating a fall on the greater trochanter. The topology of bone mineral distribution in the scan images was evaluated by image processing methods based on he Minkowski functionals (MF) using the optimized topological parameter MF2D. Correlation and multivariate analysis were employed to assess the statistical potential of BMD and MF2D with respect to predict the mechanical strength of the femur specimens. Results: R-2 for the correlation between load-to-failure and BMD varied between 0.73 and 0.79 (exponential curve fit, p < 0.001), being highest in the trochanteric ROI Correlation between load-to-failure of the specimens with the topological parameter MF2D ranged from R-2=0.8 to 0.91 (p < 0.001). In a multivariate model combining the topological information from all ROIs, correlation with MCS rose to R-2 = 0.94. Conclusion: The topological parameter MF2D can be employed to predict the mechanical strength Of Proximal femur specimens from DXA-generated images. Performance is superior to standard evaluation of DXA. In the future, the proposed image processing method may serve to improve the assessment of an individual's fracture risk. (c) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 29 条
[1]   Femoral bone mineral density, neck-shaft angle and mean femoral neck width as predictors of hip fracture in men and women [J].
Alonso, CG ;
Curiel, MD ;
Carranza, FH ;
Cano, RP ;
Pérez, AD .
OSTEOPOROSIS INTERNATIONAL, 2000, 11 (08) :714-720
[2]   Hip fracture risk and proximal femur geometry from DXA scans [J].
Bergot, C ;
Bousson, V ;
Meunier, A ;
Laval-Jeantet, M ;
Laredo, JD .
OSTEOPOROSIS INTERNATIONAL, 2002, 13 (07) :542-550
[3]   Spatial distribution of femoral bone mineral in dual energy X-ray absorptiometry images: A possible technique to improve discrimination between normal and osteoporotic patients [J].
Berry, E ;
Truscott, JG ;
Stewart, SP ;
Smith, MA .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (824) :743-750
[4]   Differentiation between post-menopausal women with and without hip fractures: enhanced evaluation of clinical DXA by topological analysis of the mineral distribution in the scan images [J].
Boehm, H. F. ;
Vogel, T. ;
Panteleon, A. ;
Burklein, D. ;
Bitterling, H. ;
Reiser, M. .
OSTEOPOROSIS INTERNATIONAL, 2007, 18 (06) :779-787
[5]   Improved performance of hip DXA using a novel region of interest in the upper part of the femoral neck - In vitro study using bone strength as a standard of reference [J].
Boehm, HF ;
Eckstein, F ;
Wunderer, C ;
Kuhn, V ;
Lochmueller, EM ;
Schreiber, K ;
Mueller, D ;
Rummeny, EJ ;
Link, TM .
JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) :488-494
[6]  
BOEHM HF, 2006, SPIE MED IMAGING, P6144
[7]   ULTRASOUND AND DENSITOMETRY OF THE CALCANEUS CORRELATE WITH THE FAILURE LOADS OF CADAVERIC FEMURS [J].
BOUXSEIN, ML ;
COURTNEY, AC ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (02) :99-103
[8]   Assessment of the strength of proximal femur in vitro: Relationship to femoral bone mineral density and femoral geometry [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
Brys, P ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 20 (03) :213-218
[9]   Femoral strength is better predicted by finite element models than QCT and DXA [J].
Cody, DD ;
Gross, GJ ;
Hou, FJ ;
Spencer, HJ ;
Goldstein, SA ;
Fyhrie, DP .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1013-1020
[10]   EFFECTS OF LOADING RATE ON STRENGTH OF THE PROXIMAL FEMUR [J].
COURTNEY, AC ;
WACHTEL, EF ;
MYERS, ER ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1994, 55 (01) :53-58