Suitability of DCPs with Screw Locking Elements to allow sufficient interfragmentary motion to promote secondary bone healing of osteoporotic fractures

被引:8
作者
Cuadrado, A. [1 ]
Yanez, A. [1 ]
Carta, J. A. [1 ]
Garces, G. [2 ]
机构
[1] Las Palmas Univ, Biomech Lab, Dept Mech Engn, Las Palmas Gran Canaria 35017, Spain
[2] Las Palmas Univ, Dept Med & Surg Sci, Las Palmas Gran Canaria 35016, Spain
关键词
Screw Locking Elements; Stiffness; Interfragmentary motion; Secondary bone healing; Locking Compression Plate; Dynamic Compression Plate; FAR CORTICAL LOCKING; PLATE FIXATION; COMPRESSION PLATE; BIOMECHANICAL EVALUATION; MECHANICAL VALIDATION; INTERNAL FIXATORS; STIFFNESS; CONSTRUCTS; FEMURS; NUMBER;
D O I
10.1016/j.medengphy.2012.08.018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper analyses the suitability of a system comprising a Dynamic Compression Plate (DCP) and Screw Locking Elements (SLEs) to allow sufficient interfragmentary motion to promote secondary bone healing in osteoporotic fractures. Four fixation systems were mounted on bone-simulating reinforced epoxy bars filled with solid rigid polyurethane foam. Group 1, used for comparison purposes, represents a system comprised of a Locking Compression Plate (LCP) and eight locking screws. Groups 2 and 3 represent a system comprised of a DCP plate with eight cortical screws and two SLEs placed on the screws furthest from (group 2) and nearest to (group 3) the fracture. Group 4 represents the system comprised of a DCP plate with SLEs placed on all eight cortical screws. Cyclic compression tests of up to 10,000 load cycles were performed in order to determine the parameters of interest, namely the stiffnesses and the interfragmentary motion of the various configurations under consideration. Tukey's multiple comparison test was used to analyse the existence or otherwise of significant differences between the means of the groups. At 10,000 cycles, interfragmentary motion at the far cortex for group 2 was 0.60 +/- 0.04 mm and for group 3 0.59 +/- 0.03 mm (there being no significant differences: p = 0.995). The mean interfragmentary motion at the far cortex of the LCP construct was 70% less than that of the two groups with 2SLEs (there being significant differences: p = 1.1 x 10(-8)). In the case of group 4 this figure was 45% less than in groups 2 and 3 (there being significant differences: p = 5.6 x 10(-6)). At 10,000 cycles, interfragmentary motion at the near cortex for group 2 was 0.24 +/- 0.06 mm and for group 30.24 +/- 0.03 mm (there being no significant differences: p = 1.000). The mean interfragmentary motion at the near cortex of the LCP construct was 70.8% less than that of the two groups with 2SLEs (there being significant differences: p = 0.011). In the case of group 4 this figure was 66.7% less than in groups 2 and 3 (there being significant differences: p = 0.016). The mean stiffness at 10,000 cycles was 960 +/- 110 N mm(-1) for group 2 and 969 +/- 53 N mm(-1) for group 3 (there being no significant differences: p = 1.000). For group 1 (the LCP construct) the mean stiffness at 10,000 cycles was 3144 +/- 446 N mm(-1), 3.25 times higher than that of groups 2 and 3 (there being significant differences: p = 0.00002), and 1.6 times higher than that of the DCP + 8SLEs construct (1944 +/- 408 N mm-1, there being significant differences: p = 0.007). It is concluded that using the DCP + 2SLEs construct sufficient interfragmentary motion is ensured to promote secondary bone healing. However, if too many SLEs are used the result may be, as with the LCP, an excessively rigid system for callus formation. (c) 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:852 / 859
页数:8
相关论文
共 45 条
  • [1] Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability?
    Ahmad, M.
    Nanda, R.
    Bajwa, A. S.
    Candal-Couto, J.
    Green, S.
    Hui, A. C.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03): : 358 - 364
  • [2] Experimental evaluation of the holding power/stiffness of the self-tapping bone screws in normal and osteoporotic bone material
    Battula, Suneel
    Schoenfeld, Andrew
    Vrabec, Gregory
    Njus, Glen O.
    [J]. CLINICAL BIOMECHANICS, 2006, 21 (05) : 533 - 537
  • [3] Bottlang M, 2011, J ORTHOP TRAUMA, V25, pS21, DOI 10.1097/01.bot.0000398506.96521.7f
  • [4] Effects of Construct Stiffness on Healing of Fractures Stabilized with Locking Plates
    Bottlang, Michael
    Doornink, Josef
    Lujan, Trevor J.
    Fitzpatrick, Daniel C.
    Marsh, Lawrence
    Augat, Peter
    von Rechenberg, Brigitte
    Lesser, Maren
    Madey, Steven M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A : 12 - 22
  • [5] Far Cortical Locking Can Improve Healing of Fractures Stabilized with Locking Plates
    Bottlang, Michael
    Lesser, Maren
    Koerber, Julia
    Doornink, Josef
    von Rechenberg, Brigitte
    Augat, Peter
    Fitzpatrick, Daniel C.
    Madey, Steven M.
    Marsh, J. Lawrence
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07) : 1652 - 1660
  • [6] Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength
    Bottlang, Michael
    Doornink, Josef
    Fitzpatrick, Daniel C.
    Madey, Steven M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) : 1985 - 1994
  • [7] A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis
    Bottlang, Michael
    Doornink, Josef
    Byrd, Gregory D.
    Fitzpatrick, Daniel C.
    Madey, Steven M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) : 620 - 627
  • [8] Biomechanical considerations of fracture treatment and bone quality maintenance in elderly patients and patients with osteoporosis
    Chao, EYS
    Inoue, N
    Koo, TKK
    Kim, YH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) : 12 - 25
  • [9] Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
  • [10] Mechanical validation of whole bone composite femur models
    Cristofolini, L
    Viceconti, M
    Cappello, A
    Toni, A
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 525 - 535