Aptamer-based impedimetric determination of the human blood clotting factor IX in serum using an interdigitated electrode modified with a ZnO nanolayer

被引:27
作者
Cheen, Ong Chong [1 ,2 ]
Gopinath, Subash C. B. [1 ,3 ]
Perumal, Veeradasan [1 ,4 ]
Arshad, M. K. Md [1 ]
Lakshmipriya, Thangavel [1 ]
Chen, Yeng [5 ,6 ]
Haarindraprasad, R. [1 ]
Rao, Balakrishnan S. [1 ,7 ]
Hashim, Uda [1 ]
Pandian, Kannaiyan [8 ]
机构
[1] Univ Perlis, INEE, Kangar 01000, Perlis, Malaysia
[2] Univ Malaysia Perlis, Fac Engn Technol, Kangar 01000, Perlis, Malaysia
[3] Univ Malaysia Perlis, Sch Bioproc Engn, Arau 02600, Perlis, Malaysia
[4] Univ Teknol PETRONAS, Ctr Innovat Nanostruct & Nanodevices COINN, Bandar Seri Iskandar 32610, Perak Darul Rid, Malaysia
[5] Dept Oral Biol & Craniofacial Sci, Kuala Lumpur, Malaysia
[6] Univ Malaya, Fac Dent, OCRCC, Kuala Lumpur 50603, Malaysia
[7] USIM, Fak Kejuruteraan & Alam Bina, Nilai 71800, Negeri Sembilan, Malaysia
[8] Univ Madras, Dept Inorgan Chem, Guindy Campus, Madras 600025, Tamil Nadu, India
关键词
Coagulation; Hemophilia; Impedance; Resistance analysis; Factor IX; Aptamer; Monoclonal antibody; Clotting; RNA APTAMER; GOLD NANOPARTICLES; SENSORS; BINDING; ASSAY; COAGULATION; SENSITIVITY; BIOSENSOR; RESONANCE; BLOCKING;
D O I
10.1007/s00604-016-2001-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes a sensitive impedimetric method for the determination of human blood coagulation factor IX protein (FIX) which is present in extremely low concentration in serum. An interdigitated electrode (IDE) whose surface was layered with zinc oxide was modified with two kinds of probes. One is an antibody, the other an aptamer against FIX. A comparative study between anti-FIX aptamer and anti-FIX antibody showed the aptamer to possess higher affinity for FIX. A sandwich aptamer assay was worked out by using the FIX-binding aptamer on the surface of the IDE. It has a detection limit as low as 10 pM which makes it 4 to 30-fold more sensitive than any other method reported for FIX. Moreover, to practice detection in clinical samples, FIX was detected from the human blood serum by spiking. In our perception, the sensitivity of the ZnO-modified IDE presented here makes it a promising tool for sensing clinically relevant analytes that are present in very low (sub-pM) concentrations.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 35 条
[21]   A high-performance waveguide-mode biosensor for detection of factor IX using PEG-based blocking agents to suppress non-specific binding and improve sensitivity [J].
Lakshmipriya, Thangavel ;
Fujimaki, Makoto ;
Gopinath, Subash C. B. ;
Awazu, Koichi ;
Horiguchi, Yukichi ;
Nagasaki, Yukio .
ANALYST, 2013, 138 (10) :2863-2870
[22]   Factor IX and thrombosis [J].
Lowe, GDO .
BRITISH JOURNAL OF HAEMATOLOGY, 2001, 115 (03) :507-513
[23]   A novel colorimetric aptasensor using cysteamine-stabilized gold nanoparticles as probe for rapid and specific detection of tetracycline in raw milk [J].
Luo, Yeli ;
Xu, Jingyue ;
Li, Ying ;
Gao, Hanting ;
Guo, Jiajia ;
Shen, Fei ;
Sun, Chunyan .
FOOD CONTROL, 2015, 54 :7-15
[24]   From selection hits to clinical leads: progress in aptamer discovery [J].
Maier, Keith E. ;
Levy, Matthew .
MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2016, 3 :16014
[25]   Electrochemical impedance spectroscopy biosensor with interdigitated electrode for detection of human immunoglobulin A [J].
Ohno, Ryuzo ;
Ohnuki, Hitoshi ;
Wang, Huihui ;
Yokoyama, Takuya ;
Endo, Hideaki ;
Tsuya, Daiju ;
Izumi, Mitsuru .
BIOSENSORS & BIOELECTRONICS, 2013, 40 (01) :422-426
[26]   A colorimetric sandwich-type assay for sensitive thrombin detection based on enzyme-linked aptamer assay [J].
Park, Jun Hee ;
Cho, Yea Seul ;
Kang, Sungmuk ;
Lee, Eun Jeong ;
Lee, Gwan-Ho ;
Hah, Sang Soo .
ANALYTICAL BIOCHEMISTRY, 2014, 462 :10-12
[27]   'Spotted Nanoflowers': Gold-seeded Zinc Oxide Nanohybrid for Selective Bio-capture [J].
Perumal, Veeradasan ;
Hashim, U. ;
Gopinath, Subash C. B. ;
Haarindraprasad, R. ;
Foo, K. L. ;
Balakrishnan, S. R. ;
Poopalan, P. .
SCIENTIFIC REPORTS, 2015, 5
[28]   A Phase 2, randomized, partially blinded, active-controlled study assessing the efficacy and safety of variable anticoagulation reversal using the REG1 system in patients with acute coronary syndromes: results of the RADAR trial [J].
Povsic, Thomas J. ;
Vavalle, John P. ;
Aberle, Laura H. ;
Kasprzak, Jaroslaw D. ;
Cohen, Mauricio G. ;
Mehran, Roxana ;
Bode, Christoph ;
Buller, Christopher E. ;
Montalescot, Gilles ;
Cornel, Jan H. ;
Rynkiewicz, Andrzej ;
Ring, Michael E. ;
Zeymer, Uwe ;
Natarajan, Madhu ;
Delarche, Nicolas ;
Zelenkofske, Steven L. ;
Becker, Richard C. ;
Alexander, John H. .
EUROPEAN HEART JOURNAL, 2013, 34 (31) :2481-2489
[29]   Impedance spectra analysis to characterize interdigitated electrodes as electrochemical sensors [J].
Rana, Sunil ;
Page, Robin H. ;
McNeil, Calum J. .
ELECTROCHIMICA ACTA, 2011, 56 (24) :8559-8563
[30]   RNA aptamers as reversible antagonists of coagulation factor IXa [J].
Rusconi, CP ;
Scardino, E ;
Layzer, J ;
Pitoc, GA ;
Ortel, TL ;
Monroe, D ;
Sullenger, BA .
NATURE, 2002, 419 (6902) :90-94