Azithromycin-molecularly imprinted polymer based on PVC membrane for Azithromycin determination in drugs using coated graphite electrode

被引:19
作者
Abu-Dalo, Muna A. [1 ]
Nassory, Nabil S. [1 ]
Abdulla, Najwa I. [2 ]
Al-Mheidat, Ismaeel R. [1 ]
机构
[1] Jordan Univ Sci & Technol, Fac Sci & Arts, Dept Chem, Irbid 22110, Jordan
[2] Univ Baghdad, Coll Educ Ibn Al Haitham, Dept Chem, Baghdad, Iraq
关键词
Azithromycin; Molecular imprinted polymer; Coated graphite electrode; Binding capacity; ION-SELECTIVE ELECTRODES;
D O I
10.1016/j.jelechem.2015.05.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several molecular imprinted polymer (MIP) membranes for Azithromycin (Azin) coated on graphite electrodes were constructed based on PVC matrix. The Azin-imprinted polymers (MIP) were prepared by thermal polymerization using acrylic acid (AA) and 2-vinyl pyridine (VPY) as monomers, ethylene glycol dimethacrylate (EGDMA) as a cross linker in the presence of benzoyl peroxide (BPO) as an initiator. Two plasticizers di-butyl phosphate (DBP) and di-octyl phthalate (DOP) were used in this study. Electrode parameters such as Nernstian slopes, concentrations, pH and interferences were studied. The results of Azin-MIP electrodes, which based on AA and VPY as monomers with DBP plasticizer, show fully Nemstian slopes. For MIP electrodes using DOP plasticizer the slopes were 49.1 and 51.3 mV/decade, respectively. Excellent detection limits for the electrodes around 10(-7) M were obtained. Life times of MIP were more than four months. The pH range for the electrodes from 3.0 to 8.0 shows no change in the electrode response and a response time around 30 s was noticed for low concentrations of Azin. The effect of some cations and neutral species interferences on electrode response was also studied. Standard addition method using graphite MIP electrode was applied for Azin determination in commercial tablets and capsules of Azin drug. The results obtained by the MIP electrode were compared with the official spectrophotometric method. The binding capacity between polymer of AA as a monomer and Azin as a template was also investigated. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 79
页数:5
相关论文
共 26 条
[11]   A Solid BindingMatrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements [J].
Kamel, Ayman H. ;
Moreira, Felismina T. C. ;
Silva, Tamara I. ;
Sales, M. Goreti F. .
INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
[12]   Molecularly imprinted polymers microsphere prepared by precipitation polymerization for hydroquinone recognition [J].
Kan, Xianwen ;
Zhao, Qun ;
Zhang, Zhong ;
Wang, Zhilin ;
Zhu, Jun-Jie .
TALANTA, 2008, 75 (01) :22-26
[13]   Magnetic molecularly imprinted polymer for aspirin recognition and controlled release [J].
Kan, Xianwen ;
Geng, Zhirong ;
Zhao, Yao ;
Wang, Zhilin ;
Zhu, Jun-Jie .
NANOTECHNOLOGY, 2009, 20 (16)
[14]   Enhanced control of an outbreak of Mycoplasma pneumoniae pneumonia with azithromycin prophylaxis [J].
Klausner, JD ;
Passaro, D ;
Rosenberg, J ;
Thacker, WL ;
Talkington, DF ;
Werner, SB ;
Vugia, DJ .
JOURNAL OF INFECTIOUS DISEASES, 1998, 177 (01) :161-166
[15]   Molecular imprint membranes of polyacrylonitrile copolymers with different acrylic acid segments [J].
Kobayashi, T ;
Wang, HY ;
Fujii, N .
ANALYTICA CHIMICA ACTA, 1998, 365 (1-3) :81-88
[16]  
Mallah MA, 2011, PAK J ANAL ENV CHEM, V12, P61
[17]   Electrochemical preparation of a molecularly imprinted polypyrrole-modified pencil graphite electrode for determination of ascorbic acid [J].
Oezcan, Levent ;
Sahin, Mutlu ;
Sahin, Yuecel .
SENSORS, 2008, 8 (09) :5792-5805
[18]   Ciprofloxacin-imprinted polymeric receptors as ionophores for potentiometric transduction [J].
Oliveira, Helena M. V. ;
Moreira, Felismina T. C. ;
Sales, M. Goreti F. .
ELECTROCHIMICA ACTA, 2011, 56 (05) :2017-2023
[19]   Electrochemical behavior of azithromycin at graphene and ionic liquid composite film modified electrode [J].
Peng, Jin Yun ;
Hou, Chuan Tao ;
Liu, Xiao Xian ;
Li, Hong Bo ;
Hu, Xiao Ya .
TALANTA, 2011, 86 :227-232
[20]  
Pesavento M., 2012, J ELECTROANAL, P813