High-resolution tracking with silicon strip detectors for relativistic ions

被引:5
作者
Hou, SR [1 ]
Alpat, B
Ambrosi, G
Balboni, C
Battiston, R
Burger, WJ
Chang, YH
Geissel, H
Ionica, M
Lustermann, W
Maehlum, G
Menichelli, M
Pauluzzi, M
Postolache, V
Produit, N
Rapin, D
Ren, D
Ribordy, M
Sann, H
Schardt, D
Sümmerer, K
Viertel, G
机构
[1] Natl Cent Univ, Chungli 320, Taiwan
[2] Ist Nazl Fis Nucl, Sez Perugia, I-06100 Perugia, Italy
[3] Univ Geneva, CH-1211 Geneva, Switzerland
[4] GSI Darmstadt, D-64291 Darmstadt, Germany
[5] ETH Zurich, CH-8093 Zurich, Switzerland
[6] IMT, Bucharest, Romania
[7] EPPG, Bucharest, Romania
关键词
D O I
10.1016/S0168-9002(99)00428-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tracking with silicon strip detectors for relativistic ions has been investigated using a C-12 beam of 1.5 GeV/u at GSI. The ionization charge spectrum and the charge sharing between strips are presented. The strip cluster of carbon ion can be selected based on the cluster charge with high efficiency and little contamination. The spatial resolution of the silicon strip detectors is evaluated. The angular distribution of multiple Coulomb scattering was investigated with lead absorbers. The results are compared to the Moliere theory and the Gaussian approximation of GEANT calculations. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 50 条
  • [31] SILICON STRIP DETECTORS
    BARKOV, IP
    GAZIZOV, IM
    KURCHANINOV, LL
    RYKALIN, VV
    SARAIKIN, AI
    STANKEVICH, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (03) : 529 - 533
  • [32] High-resolution detectors in nuclear spectroscopy
    Gerl, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3) : 238 - 243
  • [33] High-resolution Compton cameras based on Si/CdTe double-sided strip detectors
    Odaka, Hirokazu
    Ichinohe, Yuto
    Takeda, Shin'ichiro
    Fukuyama, Taro
    Hagino, Koichi
    Saito, Shinya
    Sato, Tamotsu
    Sato, Goro
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Yamaguchi, Mitsutaka
    Tanaka, Takaaki
    Tajima, Hiroyasu
    Nakazawa, Kazuhiro
    Fukazawa, Yasushi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 179 - 183
  • [34] HIGH-RESOLUTION ELECTRONIC PARTICLE DETECTORS
    CHARPAK, G
    SAULI, F
    ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1984, 34 : 285 - 349
  • [35] HIGH-RESOLUTION BLOCK DETECTORS FOR PET
    YAMASHITA, T
    WATANABE, M
    SHIMIZU, K
    UCHIDA, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 589 - 593
  • [36] THERMAL DETECTORS FOR HIGH-RESOLUTION SPECTROSCOPY
    MCCAMMON, D
    JUDA, M
    ZHANG, J
    HOLT, SS
    KELLEY, RL
    MOSELEY, SH
    SZYMKOWIAK, AE
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 : 2084 - 2091
  • [37] THERMAL DETECTORS FOR HIGH-RESOLUTION SPECTROSCOPY
    MCCAMMON, D
    JUDA, M
    ZHANG, J
    KELLEY, RL
    MOSELEY, SH
    SZYMKOWIAK, AE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 236 - 239
  • [38] Applications of silicon strip and pixel-based particle tracking detectors
    Allport, Philip
    NATURE REVIEWS PHYSICS, 2019, 1 (09) : 567 - 576
  • [39] Applications of silicon strip and pixel-based particle tracking detectors
    Philip Allport
    Nature Reviews Physics, 2019, 1 : 567 - 576
  • [40] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Soltau, H
    Strüder, L
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 25 - 28