Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes

被引:41
|
作者
Pietsch, M. [1 ]
Djahani, O. [1 ]
Zweiger, Ch [1 ]
Plattner, F. [1 ]
Radl, R. [1 ]
Tschauner, Ch [1 ]
Hofmann, S. [1 ]
机构
[1] Gen & Orthopaed Hosp Stolzalpe, Dept Orthopaed Surg, A-8852 Stolzalpe, Austria
关键词
Custom-fit; Patient specific instruments; Blood loss; Clinical outcomes; Total knee arthroplasty; INITIAL-EXPERIENCE; HIP-ARTHROPLASTY; SURGERY; INSTRUMENTATION; REPLACEMENT; MANAGEMENT; NAVIGATION; ANESTHESIA; INCISION; IMPROVE;
D O I
10.1007/s00167-012-2284-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recently, new custom-fit pin guides in total knee arthroplasty (TKA) have been introduced. Use of these guides may reduce operating time. Use of the guides combined with the absence of intramedullary alignment jigs may lead to reduced blood loss and improved early outcomes. Our aim was to evaluate blood loss and early clinical outcomes in patients undergoing minimally invasive TKA using custom-fit magnetic resonance imaging (MRI)-based pin guides. A prospective study in 80 patients was carried out. Patients were divided randomly into 2 equal groups. In one group, intramedullary alignment jigs were used. In the second group, custom-fit MRI-based pin guides were used. All patients received the same cemented posterior-stabilized implant through a mini-midvastus approach. The volume in the drain bottles was recorded after 48 h. Hb loss was estimated by subtracting the postoperative from the preoperative Hb level. Transfusion requirements and surgical time were recorded. Outcome measures were Knee Society Scores (KSS), knee flexion, knee swelling and pain. There was lower mean drainage of blood in the custom-fit group (391 ml vs. 603 ml; p < 0.0001). There was no difference in estimated loss of Hb (3.6 g/dl vs. 4.1 g/dl; n.s.) and in transfusion requirements (7.5 % vs. 10 %; n.s.). Surgical time was reduced in the custom-fit group (12 min less; p = 0.001). KSS measured at week 2, 6 and 12 showed no significant difference between groups. Knee flexion measured on days 7, 10 and at week 6, 12 and knee swelling and pain measured on days 1, 3, 10 and at week 6, 12 showed no significant difference between groups. Using custom-fit pin guides reduces blood drainage, but not the estimated Hb loss in minimally invasive TKA and does not affect transfusion rate. Surgical time is reduced. There is no effect on the early clinical outcomes. Therapeutic study, Level I.
引用
收藏
页码:2234 / 2240
页数:7
相关论文
共 50 条
  • [31] The effect of knee position on blood loss and range of motion following total knee arthroplasty
    Li, Bin
    Wen, Yu
    Liu, Da
    Tian, Lijie
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 594 - 599
  • [32] Comparison of the minimally invasive and standard medial parapatellar approaches for primary total knee arthroplasty
    Alcelik, I.
    Sukeik, M.
    Pollock, R.
    Misra, A.
    Shah, P.
    Armstrong, P.
    Dhebar, M. I.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (12) : 2502 - 2512
  • [33] Use of a haemostatic matrix (Floseal®) does not reduce blood loss in minimally invasive total knee arthroplasty performed under continued aspirin
    Schwab, Pierre-Emmanuel
    Thienpont, Emmanuel
    BLOOD TRANSFUSION, 2016, 14 (02) : 134 - 139
  • [34] The effect of aprotinin on blood loss in bilateral total knee arthroplasty
    Kinzel, V
    Shakespeare, D
    Derbyshire, D
    KNEE, 2005, 12 (02) : 107 - 111
  • [35] Effect of tourniquet use on blood loss in total knee arthroplasty
    Schuh, A
    Hausel, M
    Salminen, S
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (10): : 866 - 870
  • [36] Predicting Blood Loss in Total Knee and Hip Arthroplasty
    Sizer, Stephen C.
    Cherian, Jeffrey J.
    Elmallah, Randa D. K.
    Pierce, Todd P.
    Beaver, Walter B.
    Mont, Michael A.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (04) : 445 - +
  • [37] Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes
    Indelli, Pier Francesco
    Risitano, Salvatore
    Hall, Kimberly E.
    Leonardi, Erika
    Migliore, Eleonora
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1028 - 1034
  • [38] Navigation in Minimally Invasive Total Knee Arthroplasty and Total Hip Arthroplasty
    Hafez, Mahmoud A.
    Seel, Michael J.
    Jaramaz, Branislav
    DiGioia, Anthony M., III
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2006, 16 (03) : 207 - 210
  • [39] The effect of tranexamic acid on blood loss and use of blood products in total knee arthroplasty: a meta-analysis
    Zhang, Haoran
    Chen, Junmin
    Chen, Fei
    Que, Wenzhong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (09) : 1742 - 1752
  • [40] Knee flexion after total knee arthroplasty reduces blood loss
    Panni, Alfredo Schiavone
    Cerciello, Simone
    Vasso, Michele
    Del Regno, Chiara
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1859 - 1864