Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes

被引:43
作者
Pietsch, M. [1 ]
Djahani, O. [1 ]
Zweiger, Ch [1 ]
Plattner, F. [1 ]
Radl, R. [1 ]
Tschauner, Ch [1 ]
Hofmann, S. [1 ]
机构
[1] Gen & Orthopaed Hosp Stolzalpe, Dept Orthopaed Surg, A-8852 Stolzalpe, Austria
关键词
Custom-fit; Patient specific instruments; Blood loss; Clinical outcomes; Total knee arthroplasty; INITIAL-EXPERIENCE; HIP-ARTHROPLASTY; SURGERY; INSTRUMENTATION; REPLACEMENT; MANAGEMENT; NAVIGATION; ANESTHESIA; INCISION; IMPROVE;
D O I
10.1007/s00167-012-2284-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recently, new custom-fit pin guides in total knee arthroplasty (TKA) have been introduced. Use of these guides may reduce operating time. Use of the guides combined with the absence of intramedullary alignment jigs may lead to reduced blood loss and improved early outcomes. Our aim was to evaluate blood loss and early clinical outcomes in patients undergoing minimally invasive TKA using custom-fit magnetic resonance imaging (MRI)-based pin guides. A prospective study in 80 patients was carried out. Patients were divided randomly into 2 equal groups. In one group, intramedullary alignment jigs were used. In the second group, custom-fit MRI-based pin guides were used. All patients received the same cemented posterior-stabilized implant through a mini-midvastus approach. The volume in the drain bottles was recorded after 48 h. Hb loss was estimated by subtracting the postoperative from the preoperative Hb level. Transfusion requirements and surgical time were recorded. Outcome measures were Knee Society Scores (KSS), knee flexion, knee swelling and pain. There was lower mean drainage of blood in the custom-fit group (391 ml vs. 603 ml; p < 0.0001). There was no difference in estimated loss of Hb (3.6 g/dl vs. 4.1 g/dl; n.s.) and in transfusion requirements (7.5 % vs. 10 %; n.s.). Surgical time was reduced in the custom-fit group (12 min less; p = 0.001). KSS measured at week 2, 6 and 12 showed no significant difference between groups. Knee flexion measured on days 7, 10 and at week 6, 12 and knee swelling and pain measured on days 1, 3, 10 and at week 6, 12 showed no significant difference between groups. Using custom-fit pin guides reduces blood drainage, but not the estimated Hb loss in minimally invasive TKA and does not affect transfusion rate. Surgical time is reduced. There is no effect on the early clinical outcomes. Therapeutic study, Level I.
引用
收藏
页码:2234 / 2240
页数:7
相关论文
共 38 条
[1]  
Alfonso Daniel T, 2006, Am J Orthop (Belle Mead NJ), V35, P503
[2]  
Amer Soc Anesthesiologists Task Fo, 2006, ANESTHESIOLOGY, V105, P198
[3]  
[Anonymous], J MED ASS THAILAND
[4]  
Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften (Germany), 2003, STAT AMB THROMB CHIR
[5]   Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees [J].
Bali, Kamal ;
Walker, Peter ;
Bruce, Warwick .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1149-1154
[6]  
Bertsch C, 2007, ORTHOPADE, V36, P739, DOI 10.1007/s00132-007-1122-3
[7]   An analysis of blood management in patients having a total hip or knee arthroplasty [J].
Bierbaum, BE ;
Callaghan, JJ ;
Galante, JO ;
Rubash, HE ;
Tooms, RE ;
Welch, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :2-10
[8]   Navigation Did Not Improve the Precision of Minimally Invasive Knee Arthroplasty [J].
Bonutti, Peter M. ;
Dethmers, Daniel A. ;
McGrath, Mike S. ;
Ulrich, Slif D. ;
Mont, Michael A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2730-2735
[9]   MECHANISMS OF TRANSFUSION-INDUCED IMMUNOSUPPRESSION [J].
BRUNSON, ME ;
ALEXANDER, JW .
TRANSFUSION, 1990, 30 (07) :651-658
[10]   BLOOD LOSS AFTER MINIMALLY INVASIVE TOTAL KNEE ARTHROPLASTY: EFFECTS OF IMAGELESS NAVIGATION [J].
Chang, Chih-Wei ;
Wu, Po-Ting ;
Yang, Chyun-Yu .
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (05) :237-242