Magnetic susceptibility, artifact volume in MRI, and tensile properties of swaged Zr-Ag composites for biomedical applications

被引:13
作者
Imai, Haruki [1 ]
Tanaka, Yoji [1 ]
Nomura, Naoyuki [2 ,3 ]
Doi, Hisashi [2 ]
Tsutsumi, Yusuke [2 ]
Ono, Takashi [1 ]
Hanawa, Takao [2 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138510, Japan
[2] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
[3] Tohoku Univ, Grad Sch Engn, Dept Mat Proc, Aoba Yama 6-6-02, Sendai, Miyagi 9808579, Japan
关键词
Magnetic resonance imaging (MRI); Zr-Ag composites; Magnetic susceptibility; Artifact volume; Mechanical properties; ALLOYS; MICROSTRUCTURE; QUANTIFICATION;
D O I
10.1016/j.jmbbm.2016.11.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Zr-Ag composites were fabricated to decrease the magnetic susceptibility by compensating for the magnetic susceptibility of their components. The Zr-Ag composites with a different Zr-Ag ratio were swaged, and their magnetic susceptibility, artifact volume, and mechanical properties were evaluated by magnetic balance, three-dimensional (3-D) artifact rendering, and a tensile test, respectively. These properties were correlated with the volume fraction of Ag using the linear rule of mixture. We successfully obtained the swaged Zr-Ag composites up to the reduction ratio of 96% for Zr-4, 16, 36, 64Ag and 86% for Zr-81Ag. However, the volume fraction of Ag after swaging tended to be lower than that before swaging, especially for Ag-rich Zr-Ag composites. The magnetic susceptibility of the composites linearly decreased with the increasing volume fraction of Ag. No artifact could be estimated with the Ag volume fraction in the range from 93.7% to 95.4% in three conditions. Young's modulus, ultimate tensile strength (UTS), and 0.2% yield strength of Zr-Ag composites showed slightly lower values compared to the estimated values using a linear rule of mixture. The decrease in magnetic susceptibility of Zr and Ag by alloying or combining would contribute to the decrease of the Ag fraction, leading to the improvement of mechanical properties.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 35 条
  • [1] [Anonymous], 2010, STANDARD SPECIFICATI
  • [2] ASM, 1992, ASM HDB PROP SEL NON, V2, P3137
  • [3] Metallic artifact in MRI after removal of orthopedic implants
    Bagheri, Mohammad Hadi
    Hosseini, Mehrdad Mohammad
    Emami, Mohammad Jafar
    Foroughi, Amin Aiboulhassani
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : 584 - 590
  • [4] MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents
    Bartels, LW
    Smits, HFM
    Bakker, CJG
    Viergever, MA
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (03) : 365 - 371
  • [5] Managing Postoperative Artifacts on Computed Tomography and Magnetic Resonance Imaging
    Buckwalter, Kenneth A.
    Lin, Chen
    Ford, Jason M.
    [J]. SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2011, 15 (04) : 309 - 319
  • [6] Cancellation of metal-induced MRI artifacts with dual-component paramagnetic and diamagnetic material: Mathematical modelization and experimental verification
    Chauvel, B
    Cathelineau, G
    Balac, S
    Lecerf, J
    deCertaines, JD
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (06): : 936 - 938
  • [7] NICKEL-DOPED AGAROSE-GEL PHANTOMS IN MR IMAGING
    CHRISTOFFERSSON, JO
    OLSSON, LE
    SJOBERG, S
    [J]. ACTA RADIOLOGICA, 1991, 32 (05) : 426 - 431
  • [8] Costa ALF, 2009, MED ORAL PATOL ORAL, V14, pE278
  • [9] Influence of common orthodontic appliances on the diagnostic quality of cranial magnetic resonance images
    Elison, J. Matthew
    Leggitt, V. Leroy
    Thomson, Matthew
    Oyoyo, Udo
    Wycliffee, N. Dan
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) : 563 - 572
  • [10] Reduction of artifact of metallic implant in magnetic resonance imaging by combining paramagnetic and diamagnetic materials
    Gao, Yanhui
    Muramatsu, Kazuhiro
    Kushibe, Atsumichi
    Yamazaki, Keita
    Chiba, Akihiko
    Yamamoto, Toru
    [J]. JOURNAL OF APPLIED PHYSICS, 2010, 107 (09) : 936