An ion selective electrode for mercury(II) based on mercury(II) complex of poly(4-vinyl pyridine)

被引:45
作者
Bakhtiarzadeh, Fariba [1 ]
Ab Ghani, Sulaiman [1 ]
机构
[1] Univ Sains Malaysia, Usm 118800, Pulau Pinang, Malaysia
关键词
Ion selective electrode; Mercury(II); Plasticizer; Poly(4-vinyl pyridine);
D O I
10.1016/j.jelechem.2008.08.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study reports on the fabrication, characterization and utilization of the heterogeneous poly(Hg(II)-4-vinyl pyridine) membrane electrode. The electrode, with plasticiser tris(2-ethyl hexyl) phosphate, has a Nernstian response with slope of 30 +/- 1 mV decade(-1) in concentration range of 10(-7)-10(-2) M Hg2+, and in solution of pH 3-4. It has response and life time of less than 25 s and more than 120 days, respectively. Limit of detection is at 0.5 x 10(-7) M Hg2+. interferences from other cations are not serious, except silver(l) at mercury(II) concentration less than 10(-4) M. Analyses of water samples show that the proposed electrode agrees well with the standard method with correlation coefficient, R-2, 0.9998. The electrode is also suitable as an indicator electrode in the potentiometric titration of Hg(II) with iodide. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 42 条
  • [1] ABGHANI S, 1983, UNPUB
  • [2] Hg2+-selective membrane potentiometric sensor based on a recently synthesized mercapto compound
    Bagheri, M
    Mashhadizadeh, MH
    Razee, S
    Momeni, A
    [J]. ELECTROANALYSIS, 2003, 15 (23-24) : 1824 - 1829
  • [3] MERCURY ION-SELECTIVE POLYMERIC MEMBRANE ELECTRODES BASED ON SUBSTITUTED DIAZA CROWN ETHERS
    BRZOZKA, Z
    PIETRASZKIEWICZ, M
    [J]. ELECTROANALYSIS, 1991, 3 (08) : 855 - 858
  • [4] Cotton F. A., 1972, ADV INORG CHEM, P1145
  • [5] Ion-selective carbon paste electrode based on tetraethyl thiuram disulfide for copper(II) and mercury(II)
    Gismera, MJ
    Hueso, D
    Procopio, JR
    Sevilla, AT
    [J]. ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) : 347 - 353
  • [6] A highly selective mercury electrode based on a diamine donor ligand
    Gupta, VK
    Chandra, S
    Lang, H
    [J]. TALANTA, 2005, 66 (03) : 575 - 580
  • [7] A PVC-based pentathia-15-crown-5 membrane potentiometric sensor for mercury(II)
    Gupta, VK
    Jain, S
    Khurana, U
    [J]. ELECTROANALYSIS, 1997, 9 (06) : 478 - 480
  • [8] Poly(Fe-4-vinylpyridine) modified composite graphite paste electrode for the analysis of iron(III)
    Halim, AA
    Ab Ghani, S
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2001, 79 (02) : 155 - 165
  • [9] Jain AK, 1996, B ELECTROCHEM, V12, P418
  • [10] Javanbakht M, 1999, ELECTROANAL, V11, P81