A novel electrochemical detector using Prussian blue modified indium tin oxide electrode

被引:9
作者
Yi, IJ [1 ]
Kim, JH
Kang, CJ
Choi, YJ
Lee, K
Kim, YS
机构
[1] Myongji Univ, Dept Elect Engn, Gyeonggi 449728, South Korea
[2] Myongji Univ, Dept Phys, Gyeonggi 449728, South Korea
[3] Myongji Univ, Dept Environm Engn & Biotechnol, Gyeonggi 449728, South Korea
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS | 2006年 / 45卷 / 1B期
关键词
Prussian blue; microchip; electrochemical detection; capillary electrophoresis; electrocatalyzer;
D O I
10.1143/JJAP.45.438
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a novel electrochemical detector (ECD) to catalyze redox efficiently by electrodepositing Prussian blue (PB, ferric hexacyanoferrate) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric methods were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). The PB film on dense and smooth surfaces could catalyze redox reaction efficiently. Compared with CE-ECD microchips using a bare-ITO electrode, the proposed CE-ECD microchip using a PB modified electrode has shown better sensitivity of the electropherograms. It has been verified that wide-ranging detection can be performed under the limits of 0.01 mM of dopamine and catechol respectively when we use a PB modified electrode.
引用
收藏
页码:438 / 441
页数:4
相关论文
共 50 条
  • [31] Voltammetric determination of persulfate anions using an electrode modified with a Prussian blue film
    de Oliveira, MF
    Mortimer, RJ
    Stradiotto, NR
    MICROCHEMICAL JOURNAL, 2000, 64 (02) : 155 - 159
  • [32] Hydrogen peroxide detection using a polypyrrole/Prussian blue nanowire modified electrode
    Meng Lin
    Jiao Yang
    Misuk Cho
    Youngkwan Lee
    Macromolecular Research, 2011, 19 : 673 - 678
  • [33] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Yang, Jiao
    Lin, Meng
    Cho, MiSuk
    Lee, Youngkwan
    MICROCHIMICA ACTA, 2015, 182 (5-6) : 1089 - 1094
  • [34] Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase- or monoamine oxidase-modified electrodes
    Kacar, Ceren
    Erden, Pinar Esra
    Dalkiran, Berna
    Inal, Emine Kubra
    Kilic, Esma
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (08) : 1933 - 1946
  • [35] Fabrication of prussian blue/multi-walled carbon nanotubes modified electrode for electrochemical sensing of hydroxylamine
    Na Zhang
    Guangfeng Wang
    Aixia Gu
    Yuehua Feng
    Bin Fang
    Microchimica Acta, 2010, 168 : 129 - 134
  • [36] Determination of Rutin in Drinks Using an Electrode Modified with Carbon Nanotubes-Prussian Blue
    Nagles, Edgar
    Penagos-Llanos, Johisner
    Garcia-Beltran, Olimpo
    Hurtado, John
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (05) : 504 - 511
  • [37] Determination of Rutin in Drinks Using an Electrode Modified with Carbon Nanotubes-Prussian Blue
    Edgar Nagles
    Johisner Penagos-Llanos
    Olimpo García-Beltrán
    John Hurtado
    Journal of Analytical Chemistry, 2018, 73 : 504 - 511
  • [38] Fabrication of prussian blue/multi-walled carbon nanotubes modified electrode for electrochemical sensing of hydroxylamine
    Zhang, Na
    Wang, Guangfeng
    Gu, Aixia
    Feng, Yuehua
    Fang, Bin
    MICROCHIMICA ACTA, 2010, 168 (1-2) : 129 - 134
  • [39] Cholesterol biosensor based on platinium electrode modified by Prussian blue
    Wu, XQ
    Guo, XM
    Wang, R
    Zhang, ZR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (11) : 1273 - 1275
  • [40] A Novel Non-Enzymatic Glucose Sensor Based on Cobalt Nanoparticles Implantation-Modified Indium Tin Oxide Electrode
    Wang, Tong
    Yu, Yanan
    Tian, Huifeng
    Hu, Jingbo
    ELECTROANALYSIS, 2014, 26 (12) : 2693 - 2700