Performance characteristics of a point of care C-reactive protein assay

被引:27
|
作者
Roberts, WL
Schwarz, EL
Ayanian, S
Rifai, N
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84132 USA
[2] ARUP Inst Clin & Expt Pathol, Salt Lake City, UT 84108 USA
[3] Childrens Hosp, Dept Lab Med & Pathol, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Dept Lab Med & Pathol, Boston, MA 02115 USA
关键词
atherosclerosis; C-reactive protein; immunoassay; point of care; turbidimetry;
D O I
10.1016/S0009-8981(01)00657-X
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: C-reactive protein (CRP) is a non-specific marker of inflammation that can be used for atherosclerotic risk assessment. This application requires increased precision at low CRP concentrations compared to traditional assays. Methods: The Micros CRP analyzer (ABX Diagnostics) is a small bench top device. Its limit of detection, limit of quantitation, linearity and imprecision were assessed. Method comparison studies were performed using samples both inside and outside the reference interval. Anticoagulant effects and the prozone effect were also evaluated. Results: The limit of detection was 0.1 mg/l, The method was linear from 2 to 60 and 0.3 to 60 mg/l using systematic error limits of 10% and 20%, respectively. The total imprecision was < 8% for CRP concentrations from 0.7 to 9.1 mg/l. A prozone effect was seen at CRP concentrations > 500 mg/l. Using samples from 120 apparently healthy adults, the Micros CRP method demonstrated excellent concordance with the BN II high sensitivity CRP (hs-CRP) method. The Micros CRP method compared well with a nephelometric method using samples with elevated CRP concentrations. Conclusions: The Micros CRP method is adequate for atherosclerotic risk prediction in clinical practice but does not have adequate accuracy at CRP concentrations < 2 mg/l for epidemiological studies. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] Performance characteristics of an automated high-sensitivity C-reactive protein assay on the Dimension RXL analyzer
    De, BK
    Smith, LG
    Owen, WE
    Roberts, WL
    CLINICA CHIMICA ACTA, 2002, 323 (1-2) : 151 - 155
  • [2] Immunoanalytical characteristics of C-reactive protein and high sensitivity C-reactive protein
    Moutachakkir, Mariame
    Hanchi, Asma Lamrani
    Baraou, Azzedine
    Boukhira, Abderrahman
    Chellak, Saliha
    ANNALES DE BIOLOGIE CLINIQUE, 2017, 75 (02) : 225 - 229
  • [3] Diagnoses Based on C-Reactive Protein Point-of-Care Tests
    Pohanka, Miroslav
    BIOSENSORS-BASEL, 2022, 12 (05):
  • [4] Evaluation of a novel quantitative canine species-specific point-of-care assay for C-reactive protein
    Hindenberg, Sarah
    Kessler, Melanie
    Zielinsky, Sabine
    Langenstein, Judith
    Moritz, Andreas
    Bauer, Natali
    BMC VETERINARY RESEARCH, 2018, 14
  • [5] Feasibility of using C-reactive protein for point-of-care testing
    Joshi, Ashish
    Perin, Douglas Puricelli
    Gehle, Amanda
    Nsiah-Kumi, Phyllis A.
    TECHNOLOGY AND HEALTH CARE, 2013, 21 (03) : 233 - 240
  • [6] Evaluation of a novel quantitative canine species-specific point-of-care assay for C-reactive protein
    Sarah Hindenberg
    Melanie Keßler
    Sabine Zielinsky
    Judith Langenstein
    Andreas Moritz
    Natali Bauer
    BMC Veterinary Research, 14
  • [7] Evaluation of a point-of-care benchtop analyzer for quantitative measurement of C-reactive protein in canine serum and plasma
    Connolly, Sara L.
    Solter, Phil
    Don, Joo Hoo
    Jeong, Kim Hyun
    Constable, Peter D.
    VETERINARY CLINICAL PATHOLOGY, 2022, 51 (04) : 511 - 523
  • [8] AN IMMUNOTURBIDIMETRIC ASSAY FOR CANINE C-REACTIVE PROTEIN
    ECKERSALL, PD
    CONNER, JG
    HARVIE, J
    VETERINARY RESEARCH COMMUNICATIONS, 1991, 15 (01) : 17 - 24
  • [9] Influence of point-of-care C-reactive protein testing on antibiotic prescription habits in primary care in the Netherlands
    Schuijt, Tim J.
    Boss, David S.
    Musson, Ruben E. A.
    Demir, Ayse Y.
    FAMILY PRACTICE, 2018, 35 (02) : 179 - 185
  • [10] Point-of-care testing for C-reactive protein in a sequential microfluidic device
    Boonkaew, Suchanat
    Szot-Karpinska, Katarzyna
    Niedziolka-Jonsson, Joanna
    Palys, Barbara
    Jonsson-Niedziolka, Martin
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 397