Indirect photometric detection of anions in nonaqueous capillary electrophoresis employing Orange G as probe and a light-emitting diode-based detector

被引:13
|
作者
Heras, Gustavo A. Blanco [1 ,2 ]
Breadmore, Michael C. [1 ]
Johns, Cameron [1 ]
Hutchinson, Joseph P. [1 ]
Hilder, Emily F. [1 ]
Lopez-Mahia, Purificacion [2 ]
Haddad, Paul R. [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Fac Sci Engn & Technol, Hobart, Tas 7001, Australia
[2] Univ A Coruna, Dept Analyt Chem, A Zapateira, A Coruna, Spain
关键词
anions; dye; indirect photometric detection; light-emitting diode; nonaqueous capillary electrophoresis;
D O I
10.1002/elps.200800116
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method based on indirect photometric detection (IPD) in CE employing a blue LED (473 nm) as a light source and the highly absorbing (478 nm) anionic dye, Orange G, as the probe ion was developed for the sensitive analysis of inorganic and organic anions. The use of nonaqueous solvents was examined as a simple way to reduce the adsorption of the dye onto the capillary wall and to thereby improve the baseline stability. The benefits of this approach were confirmed by experiments using BGEs in methanol (MeOH) and DMSO in which superior baselines were obtained relative to those achieved using aqueous electrolyte systems. A range of commercial LEDs was tested to improve the detection performance, with a difference of 25% in sensitivity being observed between the best and worst performing LED. The final system (4 mM Orange G, 0.05% w/v hydroxypropylcellulose (HPC), 20 mM triethanolamine (TEA) in pure MeOH) exhibited stable baselines and very low LODs (0.10-0.18 mu M) for a test mixture comprising nine inorganic and organic anions. These values represent a two- to six-fold improvement over previous studies and the proposed method provides the most sensitive IPD method for the determination of anions using CE published to date. RSDs for ten replicates were in the ranges of 0.42-0.62% for migration time, 1.41-3.46% for peak area and 3.20-5.78% for peak height.
引用
收藏
页码:3032 / 3037
页数:6
相关论文
共 48 条
  • [1] Light-emitting diode-based indirect fluorescence detection for simultaneous determination of anions and cations in capillary electrophoresis
    Chen, SJ
    Chen, MJ
    Chang, HT
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1017 (1-2) : 215 - 224
  • [2] Sensitive indirect photometric detection of inorganic and small organic anions by capillary electrophoresis using Orange G as a probe ion
    Johns, C
    Shaw, MJ
    Macke, M
    Haddad, PR
    ELECTROPHORESIS, 2003, 24 (03) : 557 - 566
  • [3] Separation and determination of vanadium in fertiliser by capillary electrophoresis with a light-emitting diode detector
    Vachirapatama, N
    Macka, M
    Haddad, PR
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (06) : 1082 - 1085
  • [4] A collinear light-emitting diode-induced fluorescence detector for capillary electrophoresis
    Yang, BC
    Tan, F
    Guan, YF
    TALANTA, 2005, 65 (05) : 1303 - 1306
  • [5] Separation and determination of vanadium in fertiliser by capillary electrophoresis with a light-emitting diode detector
    Narumol Vachirapatama
    Miroslav Macka
    Paul R. Haddad
    Analytical and Bioanalytical Chemistry, 2002, 374 : 1082 - 1085
  • [6] A lamp light-emitting diode-induced fluorescence detector for capillary electrophoresis
    Xu, Jing
    Xiong, Yan
    Chen, Shiheng
    Guan, Yafeng
    TALANTA, 2008, 76 (02) : 369 - 372
  • [7] Evaluating Terephthalate as Probe Ion in the Analysis of Inorganic Anions by Capillary Electrophoresis with Indirect Photometric Detection
    Huang, Jinmo
    Richers, Matthew
    Woodring, Jennifer
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (13) : 1925 - 1933
  • [8] Light-emitting diode-compatible probes for indirect detection of anions in CE
    Balding, Peter
    Boyce, Mary C.
    Breadmore, Michael C.
    Macka, Mirek
    ELECTROPHORESIS, 2007, 28 (19) : 3453 - 3460
  • [9] Performance of an ultraviolet light-emitting diode-induced fluorescence detector in capillary electrophoresis
    Hillebrand, S
    Schoffen, JR
    Mandaji, M
    Termignoni, C
    Grieneisen, HPH
    Kist, TBL
    ELECTROPHORESIS, 2002, 23 (15) : 2445 - 2448
  • [10] Design and performance of a light-emitting diode detector compatible with a commercial capillary electrophoresis instrument
    Johns, C
    Macka, M
    Haddad, PR
    ELECTROPHORESIS, 2004, 25 (18-19) : 3145 - 3152