Fidelity of the Estimation of the Deformation Gradient From Data Deduced From the Motion of Markers Placed on a Body That is Subject to an Inhomogeneous Deformation Field

被引:8
作者
Prusa, Vit [1 ]
Rajagopal, K. R. [2 ]
Saravanan, U. [3 ]
机构
[1] Charles Univ Prague, Fac Math & Phys, CZ-18675 Prague, Czech Republic
[2] Texas A&M Univ, Dept Mech Engn, College Stn, TX 77843 USA
[3] Indian Inst Technol, Dept Civil Engn, Madras 600036, Tamil Nadu, India
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2013年 / 135卷 / 08期
基金
美国国家科学基金会;
关键词
NONHOMOGENEOUS ANALYSIS; MECHANICAL-BEHAVIOR; LEFT-VENTRICLE; COMPRESSIBILITY; STRAINS;
D O I
10.1115/1.4023629
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Practically all experimental measurements related to the response of nonlinear bodies that are made within a purely mechanical context are concerned with inhomogeneous deformations, though, in many experiments, much effort is taken to engender homogeneous deformation fields. However, in experiments that are carried out in vivo, one cannot control the nature of the deformation. The quantity of interest is the deformation gradient and/or its invariants. The deformation gradient is estimated by tracking positions of a finite number of markers placed in the body. Any experimental data-reduction procedure based on tracking a finite number of markers will, for a general inhomogeneous deformation, introduce an error in the determination of the deformation gradient, even in the idealized case, when the positions of the markers are measured with no error. In our study, we are interested in a quantitative description of the difference between the true gradient and its estimate obtained by tracking the markers, that is, in the quantitative description of the induced error due to the data reduction. We derive a rigorous upper bound on the error, and we discuss what factors influence the error bound and the actual error itself. Finally, we illustrate the results by studying a practically interesting model problem. We show that different choices of the tracked markers can lead to substantially different estimates of the deformation gradient and its invariants. It is alarming that even qualitative features of the material under consideration, such as the incompressibility of the body, can be evaluated differently with different choices of the tracked markers. We also demonstrate that the derived error estimate can be used as a tool for choosing the appropriate marker set that leads to the deformation gradient estimate with the least guaranteed error.
引用
收藏
页数:12
相关论文
共 27 条
  • [1] [Anonymous], 2001, Matrix Analysis and Applied Linear Algebra
  • [2] DESCRIPTION OF THE DEFORMATION OF THE LEFT-VENTRICLE BY A KINEMATIC MODEL
    ARTS, T
    HUNTER, WC
    DOUGLAS, A
    MUIJTJENS, AMM
    RENEMAN, RS
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (10) : 1119 - 1127
  • [3] COMPRESSIBILITY OF ARTERIAL WALL
    CAREW, TE
    VAISHNAV, RN
    PATEL, DJ
    [J]. CIRCULATION RESEARCH, 1968, 23 (01) : 61 - &
  • [4] The structure and mechanical properties of the mitral valve leaflet-strut chordae transition zone
    Chen, L
    Yin, FCP
    May-Newman, K
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (02): : 244 - 251
  • [5] COMPRESSIBILITY AND CONSTITUTIVE EQUATION OF ARTERIAL-WALL IN RADIAL COMPRESSION EXPERIMENTS
    CHUONG, CJ
    FUNG, YC
    [J]. JOURNAL OF BIOMECHANICS, 1984, 17 (01) : 35 - 40
  • [6] Evans L.C., 1998, PARTIAL DIFFERENTIAL, V19
  • [7] A bi-plane video-based system for studying the mechanics of arterial bifurcations
    Everett, WN
    Shih, P
    Humphrey, JD
    [J]. EXPERIMENTAL MECHANICS, 2005, 45 (04) : 377 - 382
  • [8] A video-optical system for time-resolved whole-body measurement on vascular segments
    Genovese, Katia
    [J]. OPTICS AND LASERS IN ENGINEERING, 2009, 47 (09) : 995 - 1008
  • [9] Selected methods for imaging elastic properties of biological tissues
    Greenleaf, JF
    Fatemi, M
    Insana, M
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2003, 5 : 57 - 78
  • [10] Kinetics of thermal damage to a collagenous membrane under biaxial isotonic loading
    Harris, JL
    Humphrey, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (02) : 371 - 379