Radiofrequency ablation lesion detection using MR-based electrical conductivity imaging: A feasibility study of ex vivo liver experiments

被引:8
|
作者
Chauhan, Munish [1 ]
Jeong, Woo Chul [1 ]
Kim, Hyung Joong [1 ]
Kwon, Oh In [2 ]
Woo, Eung Je [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Yongin 446701, Gyeonggi, South Korea
[2] Konkuk Univ, Dept Math, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Coagulation necrosis; conductivity image; hyperaemic rim; MREIT; radiofrequency ablation; HEPATOCELLULAR-CARCINOMA; DIELECTRIC-PROPERTIES; IMPEDANCE TOMOGRAPHY; THERMAL ABLATION; RF ABLATION; TEMPERATURE; MREIT; TUMORS; CT;
D O I
10.3109/02656736.2013.842265
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to show the potential of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging in terms of its capability to detect ablated lesions and differentiate tissue conditions in liver radiofrequency (RF) ablation. Materials and methods: RF ablation procedures were performed in bovine livers using a LeVeen RF needle electrode. Ablation lesions were created using a power-controlled mode at 30, 50, and 70 W for 1, 3, and 5 min of exposure time, respectively. After the ablation, the liver was cut into several blocks including the ablated lesion, and positioned inside a phantom filled with agarose gel. Electrodes were attached on the side of the phantom and it was placed inside the MRI bore. For MREIT imaging, multi-spin-echo pulse sequence was used to obtain the magnetic flux density data according to the injection currents. Results: The conductivity of ablation lesions was significantly changed with the increase of exposure time (pKW < 0.01, Kruskal-Wallis test). With RF powers of 30 and 50 W, significant differences between the coagulation necrosis and hyperaemic rim were observed for more than 5 min and 3 min, respectively (pMW < 0.01, Mann-Whitney test). At 70 W, all cases showed significant differences except 3 min (pMW < 0.01). The positive correlation between the exposure time and tissue conductivity was observed in both two ablation areas (pSC < 0.01, Spearman correlation). Conclusions: This ex vivo feasibility study demonstrates that current MREIT conductivity imaging can detect liver RF ablation lesions without using any contrast media or additional MR scan.
引用
收藏
页码:643 / 652
页数:10
相关论文
共 50 条
  • [41] Gradient-based electrical conductivity imaging using MR phase
    Gurler, Necip
    Ider, Yusuf Ziya
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 137 - 150
  • [42] Radiofrequency ablation with a new perfused-cooled electrode using a single pump:: An experimental study in Ex vivo bovine liver
    Kim, SK
    Se, JW
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (06) : 779 - 788
  • [43] Radiofrequency Ablation with a New Perfused-Cooled Electrode Using a Single Pump: An Experimental Study in Ex Vivo Bovine Liver
    Seung Kwon Kim
    Jung Wook Seo
    CardioVascular and Interventional Radiology, 2005, 28 : 779 - 788
  • [44] Real time monitoring of radiofrequency ablation based on MR thermometry and thermal dose in the pig liver in vivo
    Seror, Olivier
    Lepetit-Coiffe, Matthieu
    Le Bail, Brigitte
    de Senneville, Baudouin Denis
    Trillaud, Herve
    Moonen, Chrit
    Quesson, Bruno
    EUROPEAN RADIOLOGY, 2008, 18 (02) : 408 - 416
  • [45] Radiofrequency ablation using injectable cooled electrode: the effects of lidocaine injection in ex vivo study
    Park, Sun-Young
    Chung, Hye Won
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Lee, Min Hee
    Lee, Joon Woo
    ACTA RADIOLOGICA, 2020, 61 (02) : 219 - 226
  • [46] Real time monitoring of radiofrequency ablation based on MR thermometry and thermal dose in the pig liver in vivo
    Olivier Seror
    Matthieu Lepetit-Coiffé
    Brigitte Le Bail
    Baudouin Denis de Senneville
    Hervé Trillaud
    Chrit Moonen
    Bruno Quesson
    European Radiology, 2008, 18 : 408 - 416
  • [47] Unidirectional Ablation Electrode to Minimize Thermal Injury During Radiofrequency Ablation: An Experimental Study in an Ex Vivo Bovine Liver Model
    Na, Dong Gyu
    Lee, Jeong Hyun
    Kim, Sun Mi
    Lim, Hyun Kyung
    Baek, Jung Hwan
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (07) : 935 - 940
  • [48] Fiber-optic combined FPI/FBG sensors for monitoring of radiofrequency thermal ablation of liver tumors: ex vivo experiments
    Tosi, Daniele
    Macchi, Edoardo Gino
    Braschi, Giovanni
    Cigada, Alfredo
    Gallati, Mario
    Rossi, Sandro
    Poeggel, Sven
    Leen, Gabriel
    Lewis, Elfed
    APPLIED OPTICS, 2014, 53 (10) : 2136 - 2144
  • [49] Applicator for RF Thermokeratoplasty: Feasibility Study Using Theoretical Modeling and Ex Vivo Experiments
    Trujillo, Macarena
    Ribera, Vicente
    Quesada, Rita
    Berjano, Enrique
    ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (05) : 1182 - 1191
  • [50] Increased Ablation Zones Using a Cryo-Based Internally Cooled Bipolar RF Applicator in Ex Vivo Bovine Liver
    Rempp, Hansjoerg
    Voigtlaender, Matthias
    Clasen, Stephan
    Kempf, Simone
    Neugebauer, Alexander
    Schraml, Christina
    Schmidt, Diethard
    Claussen, Claus D.
    Enderle, Markus D.
    Goldberg, S. Nahum
    Pereira, Philippe L.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (12) : 763 - 768