Radiofrequency ablation lesion detection using MR-based electrical conductivity imaging: A feasibility study of ex vivo liver experiments

被引:8
|
作者
Chauhan, Munish [1 ]
Jeong, Woo Chul [1 ]
Kim, Hyung Joong [1 ]
Kwon, Oh In [2 ]
Woo, Eung Je [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Yongin 446701, Gyeonggi, South Korea
[2] Konkuk Univ, Dept Math, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Coagulation necrosis; conductivity image; hyperaemic rim; MREIT; radiofrequency ablation; HEPATOCELLULAR-CARCINOMA; DIELECTRIC-PROPERTIES; IMPEDANCE TOMOGRAPHY; THERMAL ABLATION; RF ABLATION; TEMPERATURE; MREIT; TUMORS; CT;
D O I
10.3109/02656736.2013.842265
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to show the potential of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging in terms of its capability to detect ablated lesions and differentiate tissue conditions in liver radiofrequency (RF) ablation. Materials and methods: RF ablation procedures were performed in bovine livers using a LeVeen RF needle electrode. Ablation lesions were created using a power-controlled mode at 30, 50, and 70 W for 1, 3, and 5 min of exposure time, respectively. After the ablation, the liver was cut into several blocks including the ablated lesion, and positioned inside a phantom filled with agarose gel. Electrodes were attached on the side of the phantom and it was placed inside the MRI bore. For MREIT imaging, multi-spin-echo pulse sequence was used to obtain the magnetic flux density data according to the injection currents. Results: The conductivity of ablation lesions was significantly changed with the increase of exposure time (pKW < 0.01, Kruskal-Wallis test). With RF powers of 30 and 50 W, significant differences between the coagulation necrosis and hyperaemic rim were observed for more than 5 min and 3 min, respectively (pMW < 0.01, Mann-Whitney test). At 70 W, all cases showed significant differences except 3 min (pMW < 0.01). The positive correlation between the exposure time and tissue conductivity was observed in both two ablation areas (pSC < 0.01, Spearman correlation). Conclusions: This ex vivo feasibility study demonstrates that current MREIT conductivity imaging can detect liver RF ablation lesions without using any contrast media or additional MR scan.
引用
收藏
页码:643 / 652
页数:10
相关论文
共 50 条
  • [31] Combined treatment of radiofrequency ablation and acetic acid injection: an in vivo feasibility study in rabbit liver
    Lee, JM
    Lee, YH
    Kim, YK
    Kim, SW
    Kim, SH
    Han, JK
    Choi, BI
    EUROPEAN RADIOLOGY, 2004, 14 (07) : 1303 - 1310
  • [32] Hyperspectral image-based analysis of thermal damage for ex-vivo bovine liver utilizing radiofrequency ablation
    Aref, Mohamed Hisham
    Aboughaleb, Ibrahim H.
    Youssef, Abou-Bakr M.
    El-Sharkawy, Yasser H.
    SURGICAL ONCOLOGY-OXFORD, 2021, 38
  • [33] Real-time estimation of lesion depth and control of radiofrequency ablation within ex vivo animal tissues using a neural network
    Wang, Yearnchee Curtis
    Chan, Terence Chee-Hung
    Sahakian, Alan Varteres
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (07) : 1104 - 1113
  • [34] Feasibility of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging to evaluate brain abscess lesion: In vivo canine model
    Oh, Tong In
    Jeong, Woo Chul
    McEwan, Alistair
    Park, Hee Myung
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 189 - 197
  • [35] Electrical conductivity-based contrast imaging for characterizing prostatic tissues: in vivo animal feasibility study
    Cho, Yong Soo
    Hur, Young Hoe
    Seon, Hyun Ju
    Kim, Jin Woong
    Kim, Hyung Joong
    BMC UROLOGY, 2019, 19 (01)
  • [36] Evaluation of Effects of Radiofrequency Ablation of Ex vivo Liver Using the 1-Fr Wire Electrode
    Rustagi, Tarun
    Gleeson, Ferga C.
    Abu Dayyeh, Barham K.
    Topazian, Mark D.
    Levy, Michael J.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2018, 52 (02) : 168 - 171
  • [37] Microwave ablation assisted by a computerised tomography--ultrasonography fusion imaging system for liver lesions: An ex vivo experimental study
    Yu, Xiaoling
    Liu, Fangyi
    Liang, Ping
    Era, Alex Dell
    Cheng, Zhigang
    Han, Zhiyu
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2011, 27 (02) : 172 - 179
  • [38] A Newly Developed Perfused Umbrella Electrode for Radiofrequency Ablation: An Ex Vivo Evaluation Study in Bovine Liver
    Philipp Bruners
    Jochen Pfeffer
    Rana M. Kazim
    Rolf W. Günther
    Thomas Schmitz-Rode
    Andreas H. Mahnken
    CardioVascular and Interventional Radiology, 2007, 30 : 992 - 998
  • [39] MONITORING MICROWAVE ABLATION OF EX VIVO BOVINE LIVER USING ULTRASONIC ATTENUATION IMAGING
    Samimi, Kayvan
    White, James K.
    Brace, Christopher L.
    Varghese, Tomy
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (07) : 1441 - 1451
  • [40] A newly developed perfused umbrella electrode for radiofrequency ablation:: An ex vivo evaluation study in bovine liver
    Bruners, Philipp
    Pfeffer, Jochen
    Kazim, Rana M.
    Guenther, Rolf W.
    Schmitz-Rode, Thomas
    Mahnken, Andreas H.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (05) : 992 - 998