One-way and two-way pulsed electromembrane extraction for trace analysis of amino acids in foods and biological samples

被引:76
作者
Rezazadeh, Maryam [1 ]
Yamini, Yadollah [1 ]
Seidi, Shahram [1 ]
Esrafili, Ali [2 ]
机构
[1] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
关键词
Pulsed electromembrane extraction; Amino acids; Biological fluid; Food sample; CONTACTLESS CONDUCTIVITY DETECTION; CHROMATOGRAPHY-MASS SPECTROMETRY; ELECTRO MEMBRANE EXTRACTION; ARTIFICIAL LIQUID-MEMBRANES; CAPILLARY-ELECTROPHORESIS; GAS-CHROMATOGRAPHY; BASIC DRUGS; BODY-FLUIDS; TRYPTOPHAN; MIGRATION;
D O I
10.1016/j.aca.2013.02.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, pulsed electromembrane extraction (PEME) was performed for the first time, as a new concept of electrically enhanced microextraction method, for extraction and quantification of histidine, phenylalanine and tryptophan in different matrices. PEME offers an alternative to conventional electromembrane extraction (EME), which faces problems such as serious instabilities in the analysis of real samples with high concentration levels of ions. In these samples, increasing of the ion transportation across the liquid membrane results in Joule heating during the extraction process which may follow by punctuation of the organic membrane, increasing of the current level and bubble formation due to electrolysis reactions. A mixture of 2-nitrophenyl octyl ether (NPOE), di-(2-ethylhexyl) phosphate (DEHP) and tris-(2-ethylhexyl) phosphate (TEHP) was immobilized in the pores of hollow fiber as the organic liquid membrane. Other effective parameters such as extraction time, ion balance and pulse frequency were optimized using the experimental design. Extraction recoveries in the range of 7.1-21.6% and satisfactory repeatability (2.1 < CV% < 4.5) were obtained. Limits of detection were 5, 10 and 30 ng mL(-1) for tryptophan, phenylalanine and histidine, respectively. The method offers acceptable linearity with correlation coefficients higher than 0.9979. Furthermore, the figures of merit of PEME are compared with the results from conventional electromembrane extraction (EME), which proves the advantages of the proposed technique. The method was applied to the determination and quantification of amino acids in foods and biological samples. Also, two-way PEME was employed as a novel approach for highly selective extraction of tryptophan as a model analyte to introduce an interesting ability of the proposed technique. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 30 条
[1]   Electromembrane extraction of peptides [J].
Balchen, Marte ;
Reubsaet, Leon ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1194 (02) :143-149
[2]   Electrokinetic migration of acidic drugs across a supported liquid membrane [J].
Balchen, Marte ;
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :220-225
[3]   Rapid isolation of angiotensin peptides from plasma by electromembrane extraction [J].
Balchen, Marte ;
Halvorsen, Trine Gronhaug ;
Reubsaet, Leon ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (41) :6900-6905
[4]   ON THE EXPERIMENTAL ATTAINMENT OF OPTIMUM CONDITIONS [J].
BOX, GEP ;
WILSON, KB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1951, 13 (01) :1-45
[5]   Plasma tryptophan, kynurenine and 3-hydroxykynurenine measurement using automated on-line solid-phase extraction HPLC-tandem mass spectrometry [J].
de Jong, Wilhelmina H. A. ;
Smit, Reinier ;
Bakker, Stephan J. L. ;
de Vries, Elisabeth G. E. ;
Kema, Ido P. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (07) :603-609
[6]   Rapid diagnosis of phenylketonuria and other aminoacidemias by quantitative analysis of amino acids in neonatal blood spots by gas chromatography-mass spectrometry [J].
Deng, CH ;
Shang, CQ ;
Hu, YM ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 775 (01) :115-120
[7]   Exhaustive electromembrane extraction of some basic drugs from human plasma followed by liquid chromatography-mass spectrometry [J].
Eibak, Lars Erik Eng ;
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 :33-38
[8]   Simple and rapid quantitative high-performance liquid chromatographic analysis of plasma amino acids [J].
Frank, Michael P. ;
Powers, Robert W. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :646-649
[9]   Microextraction across supported liquid membranes forced by pH gradients and electrical fields [J].
Gjelstad, Astrid ;
Andersen, Torill Marita ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :38-45
[10]   Electrokinetic migration across artificial liquid membranes - Tuning the membrane chemistry to different types of drug substances [J].
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) :29-34