Vapor Intrusion Screening at Petroleum UST Sites

被引:44
|
作者
Lahvis, Matthew A. [1 ]
Hers, Ian [2 ]
Davis, Robin V. [3 ]
Wright, Jackie [4 ]
DeVaull, George E. [1 ]
机构
[1] Shell Global Solut US, Shell Technol Ctr Houston, Houston, TX 77082 USA
[2] Golder Associates, Burnaby, BC V5C 6C6, Canada
[3] Utah Dept Environm Qual, Salt Lake City, UT 84116 USA
[4] Environm Risk Sci Pty Ltd, Carlingford, NSW 2118, Australia
关键词
OXYGEN-LIMITED BIODEGRADATION; INDOOR AIR; AEROBIC BIODEGRADATION; GROUND-WATER; ATTENUATION; ZONE; QUANTIFICATION; HYDROCARBONS; PREDICTION; BUILDINGS;
D O I
10.1111/gwmr.12005
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Detailed site investigations to assess potential inhalation exposure and risk to human health associated with the migration of petroleum hydrocarbon vapors from the subsurface to indoor air are frequently undertaken at leaking underground storage tank (UST) sites, yet documented occurrences of petroleum vapor intrusion are extremely rare. Additional assessments are largely driven by low screening-level concentrations derived from vapor transport modeling that does not consider biodegradation. To address this issue, screening criteria were developed from soil-gas measurements at hundreds of petroleum UST sites spanning a range of environmental conditions, geographic regions, and a 16-year time period (1995 to 2011). The data were evaluated to define vertical separation (screening) distances from the source, beyond which, the potential for vapor intrusion can be considered negligible. The screening distances were derived explicitly from benzene data using specified soil-gas screening levels of 30, 50, and 100 mu g/m3 and nonparametric Kaplan-Meier statistics. Results indicate that more than 95% of benzene concentrations in soil gas are 30 mu g/m3 at any distance above a dissolved-phase hydrocarbon source. Dissolved-phase petroleum hydrocarbon sources are therefore unlikely to pose a risk for vapor intrusion unless groundwater (including capillary fringe) comes in contact with a building foundation. For light nonaqueous-phase liquid (LNAPL) hydrocarbon sources, more than 95% of benzene concentrations in soil gas are 30 mu g/m3 for vertical screening distances of 13ft (4m) or greater. The screening distances derived from this analysis are markedly different from 30 to 100ft (10 to 30m) vertical distances commonly found cited in regulatory guidance, even with specific allowances to account for uncertainty in the hydrocarbon source depth or location. Consideration of these screening distances in vapor intrusion guidance would help eliminate unnecessary site characterization at petroleum UST sites and allow more effective and sustainable use of limited resources.
引用
收藏
页码:53 / 67
页数:15
相关论文
共 50 条
  • [41] Analytical modeling of the subsurface volatile organic vapor concentration in vapor intrusion
    Shen, Rui
    Pennell, Kelly G.
    Suuberg, Eric M.
    CHEMOSPHERE, 2014, 95 : 140 - 149
  • [42] A two-dimensional analytical model of vapor intrusion involving vertical heterogeneity
    Yao, Yijun
    Verginelli, Iason
    Suuberg, Eric M.
    WATER RESOURCES RESEARCH, 2017, 53 (05) : 4499 - 4513
  • [43] Comparison of the Johnson-Ettinger Vapor Intrusion Screening Model Predictions with Full Three-Dimensional Model Results
    Yao, Yijun
    Shen, Rui
    Pennell, Kelly G.
    Suuberg, Eric M.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (06) : 2227 - 2235
  • [44] Identification of Alternative Vapor Intrusion Pathways Using Controlled Pressure Testing, Soil Gas Monitoring, and Screening Model Calculations
    Guo, Yuanming
    Holton, Chase
    Luo, Hong
    Dahlen, Paul
    Gorder, Kyle
    Dettenmaier, Erik
    Johnson, Paul C.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (22) : 13472 - 13482
  • [45] Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex
    McHugh, Thomas
    Beckley, Lila
    Sullivan, Terry
    Lutes, Chris
    Truesdale, Robert
    Uppencamp, Rob
    Cosky, Brian
    Zimmerman, John
    Schumacher, Brian
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 598 : 772 - 779
  • [46] A conservative vapour intrusion screening model of oxygen-limited hydrocarbon vapour biodegradation accounting for building footprint size
    Knight, John H.
    Davis, Gregory B.
    JOURNAL OF CONTAMINANT HYDROLOGY, 2013, 155 : 46 - 54
  • [47] Research Needs Regarding the Vapor Intrusion Potential of Volatile Per- and Polyfluoroalkyl Substances
    Kapuscinski, Richard B.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (09) : 4056 - 4059
  • [48] An analytical model of vapor intrusion with fluctuated water table
    Liu, Xinyue
    Ma, Enze
    Zhang, You-Kuan
    Liang, Xiuyu
    JOURNAL OF HYDROLOGY, 2021, 596
  • [49] Empirically Derived California Vapor Intrusion Attenuation Factors
    Abbasi, Rafat
    Bosan, William
    Gallagher, Dan
    GROUND WATER MONITORING AND REMEDIATION, 2023, 43 (01) : 60 - 68
  • [50] An analytical model of bubble-facilitated vapor intrusion
    Ma, Enze
    Zhang, You-Kuan
    Liang, Xiuyu
    Yang, Jinzhong
    Zhao, Yuqing
    Liu, Xinyue
    WATER RESEARCH, 2019, 165