Image Quality and Radiation Exposure Comparison of a Double High-Pitch Acquisition for Coronary Computed Tomography Angiography Versus Standard Retrospective Spiral Acquisition in Patients With Atrial Fibrillation

被引:2
|
作者
Elias dos Prazeres, Carlos Eduardo [1 ]
Magalhaes, Tiago Augusto [1 ]
de Castro Carneiro, Adriano Camargo [1 ]
Cury, Roberto Caldeira [1 ]
Moreira, Valeria de Melo [1 ]
Silva Matsumoto Bello, Juliana Hiromi [1 ]
Rochitte, Carlos Eduardo [1 ]
机构
[1] Heart Hosp, Cardiovasc Computed Tomog & Magnet Resonance Sect, Assoc Sanatorio Sirio, Sao Paulo, Brazil
关键词
coronary CT angiography; dual-source CT; high pitch; radiation exposure; atrial fibrillation; DUAL-SOURCE CT; DIAGNOSTIC PERFORMANCE; ARTERY-DISEASE; HEART-RATE; ACCURACY; STENOSIS;
D O I
10.1097/RCT.0000000000000612
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of this study was to compare image quality and radiation dose of coronary computed tomography (CT) angiography performed with dual-source CT scanner using 2 different protocols in patients with atrial fibrillation. Methods Forty-seven patients with AF underwent 2 different acquisition protocols: double high-pitch (DHP) spiral acquisition and retrospective spiral acquisition. The image quality was ranked according to a qualitative score by 2 experts: 1, no evident motion; 2, minimal motion not influencing coronary artery luminal evaluation; and 3, motion with impaired luminal evaluation. A third expert solved any disagreement. Results A total of 732 segments were evaluated. The DHP group (24 patients, 374 segments) showed more segments classified as score 1 than the retrospective spiral acquisition group (71.3% vs 37.4%). Image quality evaluation agreement was high between observers ( = 0.8). There was significantly lower radiation exposure for the DHP group (3.65 [1.29] vs 23.57 [10.32] mSv). Conclusions In this original direct comparison, a DHP spiral protocol for coronary CT angiography acquisition in patients with atrial fibrillation resulted in lower radiation exposure and superior image quality compared with conventional spiral retrospective acquisition.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [31] Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography
    Zhang, Long Jiang
    Wang, Yining
    Schoepf, U. Joseph
    Meinel, Felix G.
    Bayer, Richard R., II
    Qi, Li
    Cao, Jian
    Zhou, Chang Sheng
    Zhao, Yan E.
    Li, Xie
    Bin Gong, Jian
    Jin, Zhengyu
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 797 - 806
  • [32] CT coronary angiography in atrial fibrillation: a comparison of radiation dose and diagnostic confidence with retrospective gating vs prospective gating with systolic acquisition
    Clayton, Benjamin
    Roobottom, Carl
    Morgan-Hughes, Gareth
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1055)
  • [33] Reduction of X-Ray Induced DNA Double-Strand Breaks in Blood Lymphocytes During Coronary CT Angiography Using High-Pitch Spiral Data Acquisition With Prospective ECG-Triggering
    Kuefner, Michael A.
    Hinkmann, Fabian M.
    Alibek, Sedat
    Azoulay, Sascha
    Anders, Katharina
    Kalender, Willi A.
    Achenbach, Stephan
    Grudzenski, Saskia
    Loebrich, Markus
    Uder, Michael
    INVESTIGATIVE RADIOLOGY, 2010, 45 (04) : 182 - 187
  • [34] Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease
    Kanie, Yuichiro
    Sato, Shuhei
    Tada, Akihiro
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2017, 38 (07) : 1393 - 1399
  • [35] Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents
    Christian A. Barrera
    Hansel J. Otero
    Ammie M. White
    David Saul
    David M. Biko
    The International Journal of Cardiovascular Imaging, 2019, 35 : 367 - 374
  • [36] Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease
    Yuichiro Kanie
    Shuhei Sato
    Akihiro Tada
    Susumu Kanazawa
    Pediatric Cardiology, 2017, 38 : 1393 - 1399
  • [37] Radiation doses from phantom measurements at high-pitch dual-source computed tomography coronary angiography
    Goetti, Robert
    Leschka, Sebastian
    Boschung, Markus
    Mayer, Sabine
    Wyss, Christophe
    Stolzmann, Paul
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : 773 - 779
  • [38] Coronary computed tomography angiography at 140 kV versus 120 kV: assessment of image quality and radiation exposure in overweight and moderately obese patients
    Lee, Ashley M.
    Engel, Leif-Christopher
    Hui, Gladwin C.
    Liew, Gary
    Ferencik, Maros
    Sidhu, Manavjot S.
    Hoffmann, Udo
    Ghoshhajra, Brian B.
    ACTA RADIOLOGICA, 2014, 55 (05) : 554 - 562
  • [39] High-Pitch Coronary Computed Tomographic Angiography Using the Third-Generation Dual-Source Computed Tomography: Initial Experience in Patients With High Heart Rate
    Feng, Ruiqi
    Mao, Jingsong
    Liu, Xiaofei
    Zhao, Yu
    Tong, Jiajie
    Zhang, Liang
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 248 - 255
  • [40] Image Quality of ECG-Triggered High-Pitch, Dual-Source Computed Tomography Angiography for Cardiovascular Assessment in Children
    Barrera, Christian A.
    Otero, Hansel J.
    White, Ammie M.
    Saul, David
    Biko, David M.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2020, 49 (01) : 23 - 28