Sensing of H2O2 at low surface density assemblies of pt nanoparticles in polyelectrolyte

被引:106
作者
Karam, Pierre [1 ]
Halaoui, Lara I. [1 ]
机构
[1] Amer Univ Beirut, Dept Chem, Beirut 110236, Lebanon
关键词
D O I
10.1021/ac702358d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric detection of H2O2 was studied at random arrays of 2.5 nm polyacrylate-capped Pt nanoparticles (NP) assembled in poly(diallydimethylammonium chloride), PDDA, as a function of NP surface coverage. The arrays were assembled by varying the adsorption time of PDDA-modified electrodes in the nanoparticles solution. Pt NP-on-PDDA assemblies exhibited significant sensitivity and stability facing constant anodic polarization and a low limit of detection at small Pt mass in submonolayer coverage. The current output was measured at approximately 0.5 A M-1 cm(geom)(-2) over a linear range from 42 nM to 0.16 mM H2O2 at a loading of 0.87 mu g(Pt)/cm(2) or an estimated coverage of 0.4 of an assumed monolayer, or higher, and decreased with decreasing NP surface density to 0.2 A M-1 cm(geom)(-2) at a Pt loading of 190 ng/cm(2.)
引用
收藏
页码:5441 / 5448
页数:8
相关论文
共 54 条
[31]  
Lingane J.J., 1963, J ELECTROANAL CHEM, V5, P411, DOI 10.1016/0022-0728(63)80050-9
[32]  
Lingane J.J., 1961, J ELECTROANAL CHEM, V2, P296
[33]   Picomolar peroxide detection using a chemically activated redox mediator and square wave voltammetry [J].
Lyon, Jennifer L. ;
Stevenson, Keith J. .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8518-8525
[34]   Oxidative stress and heart failure [J].
MacCarthy, PA ;
Shah, AM .
CORONARY ARTERY DISEASE, 2003, 14 (02) :109-113
[35]   Adsorption of atomic hydrogen at a nanostructured electrode of polyacrylate-capped Pt nanoparticles in polyelectrolyte [J].
Markarian, MZ ;
El Harakeh, M ;
Halaoui, LI .
JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (23) :11616-11621
[36]   Theoretical treatment of the amperometric current response of multiple microelectrode arrays [J].
Morf, WE .
ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) :139-149
[37]   Performance of amperometric sensors based on multiple microelectrode arrays [J].
Morf, WE ;
de Rooij, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :538-541
[38]   ELECTROCHEMISTRY AT PT BAND ELECTRODES OF WIDTH APPROACHING MOLECULAR DIMENSIONS - BREAKDOWN OF TRANSPORT-EQUATIONS AT VERY SMALL ELECTRODES [J].
MORRIS, RB ;
FRANTA, DJ ;
WHITE, HS .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (13) :3559-3564
[39]   Determination of acetylcholine and choline with platinum-black ultramicroarray electrodes using liquid chromatography with a post-column enzyme reactor [J].
Niwa, O ;
Horiuchi, T ;
Morita, M ;
Huang, TH ;
Kissinger, PT .
ANALYTICA CHIMICA ACTA, 1996, 318 (02) :167-173
[40]   On-line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue [J].
Niwa, O ;
Horiuchi, T ;
Kurita, R ;
Torimitsu, K .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1126-1132