Improvement of the MELCOR condensation heat transfer model for the thermal-hydraulic analysis of a PWR containment

被引:10
作者
Yoo, Jee Min [1 ]
Kang, Jin Hoon [1 ]
Yun, Byong Jo [1 ]
Hong, Seong Wan [2 ]
Jeong, Jae Jun [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
[2] KAERI, 989-111 Daedeok Daero, Daejeon 34057, South Korea
基金
新加坡国家研究基金会;
关键词
Condensation heat transfer; Noncondensable gases; MELCOR; Containment; STEAM CONDENSATION; COOLING SYSTEM; AIR; MIXTURES; DESIGN; GASES; VAPOR; RATES;
D O I
10.1016/j.pnucene.2017.09.012
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
During a hypothetical loss-of-coolant accident or a severe accident in a light water nuclear reactor (LWR), condensation heat transfer directly affects the pressure behavior and hydrogen distribution in the containment. This work aims at the improvement of the condensation heat transfer model in the MELCOR code, which is a fully-integrated computer code that models the progression of severe accidents in a LWR. It is known that MELCOR generally under-predicts the condensation heat transfer. For the improvement of MELCOR, we have assessed the MELCOR condensation model first. Other two models developed by Liao and Dehbi were also assessed for a comparative study. The assessment range is limited to the thermal-hydraulic conditions inside the containment building during a hypothetical design basis accident or a severe accident. We selected six condensation experiments of COPAIN, CONAN, Park, Anderson, Dehbi, and Kang and, then, assessed the three models against these data. The results of calculations showed that the MELCOR condensation model generally under-predicts the condensation heat transfer by about 45% and, however, it is the most precise and consistent in comparison with the other two models. Based on these results, the MELCOR model was selected as a base for model improvement. Then, four modifications were suggested: The effect of condensing surface curvature on condensation was considered into the MELCOR model first. The effective diffusion coefficient is applied for steam-air helium tests. A multiplier to enhance condensation was obtained from the best fit of the calculated-to measured plot. At last, to reflect the effect of superheated steam, a degradation factor deduced from the COPAIN experiment was adopted. The results of the modified MELCOR model showed very good agreements with most of the experimental data within +/- 30% error. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:172 / 182
页数:11
相关论文
共 38 条
[1]   FREE CONVECTION FILM CONDENSATION OF STEAM IN PRESENCE OF NON-CONDENSING GASES [J].
ALDIWANY, HK ;
ROSE, JW .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (07) :1359-1369
[2]  
Ambrosini W., 2008, 3 EUR REV M SEV ACC
[3]  
Anderson M. H., 1998, THESIS
[4]  
[Anonymous], THESIS
[5]  
[Anonymous], THESIS
[6]   THE VISCOSITY AND THERMAL-CONDUCTIVITY OF PURE MONATOMIC GASES FROM THEIR NORMAL BOILING-POINT UP TO 5000-K IN THE LIMIT OF ZERO DENSITY AND AT 0.101325 MPA [J].
BICH, E ;
MILLAT, J ;
VOGEL, E .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1990, 19 (06) :1289-1305
[7]  
BIRD B, 1960, TRANSPORT PHENOMENA
[8]   A FILM MODEL FOR HEAT AND MASS-TRANSFER WITH FOG FORMATION [J].
BROUWERS, HJH .
CHEMICAL ENGINEERING SCIENCE, 1992, 47 (12) :3023-3036
[9]   AN IMPROVED TANGENCY CONDITION FOR FOG FORMATION IN COOLER-CONDENSERS [J].
BROUWERS, HJH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (09) :2387-2394
[10]  
Cebeci T., 1974, P 5 INT HEAT TRANSFE, VNCI., P15