Application and Assessment of Enhanced Electrolytic Process for Laundry Wastewater Treatment

被引:0
作者
Yun, ChanYoung [1 ]
Kim, DaeGun [2 ]
Kim, WooYeol [1 ]
Son, DongJin [3 ]
Chang, Duk [1 ]
Kim, JinHo [4 ]
Bae, YoonSun [5 ]
Bae, HyungSuk [5 ]
Sunwoo, Young [1 ]
Kwak, MinSeok [6 ]
Hong, KiHo [3 ]
机构
[1] Konkuk Univ, Dept Environm Engn, Seoul 143701, South Korea
[2] Green Energy & Environm GE2 Res Inst, Yeongwol Gun 230884, Gangwon Do, South Korea
[3] Konkuk Univ, Dept Adv Technol Fus, Seoul 143701, South Korea
[4] Korea Inst Ceram Engn & Technol, Seoul 153801, South Korea
[5] EnviroSolut Co Ltd, Yongin 446982, Gyeonggi Do, South Korea
[6] Kyungpook Natl Univ, Sch Architecture & Civil Engn, Taegu 702701, South Korea
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2014年 / 9卷 / 03期
关键词
Electrolytic process; Copper Electrode; Laundry Wastewater; Wastewater Treatment; ELECTROCHEMICAL TREATMENT; ELECTROCOAGULATION PROCESS; TREATMENT SYSTEM; REMOVAL; PURIFICATION; COAGULATION; DEGRADATION; PHOSPHORUS; OXIDATION; COPPER;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this research, an enhanced electrolytic process was applied and evaluated for the treatment of laundry wastewater. Treatability of the process as well as the analyses of by-product was also conducted. Most organics in laundry wastewater were formed of suspended solids and they were removed successfully by electro-coagulation mechanism. The TKN was removed completely in a very shorter retention time of three minutes; in particular, the removal of overall phosphorus was performed in only 1.4 minutes. The pH value increased whereas alkalinity decreased due to the carbonates eliminated during the electrochemical procedure. The ORP value declined because the copper electrode has oxidation-reduction half potential of -0.15V during being oxidized Cu to Cu2+. The sludge was by-product of the procedure, and its SVI was below 20mL/g. The sludge had a good settleability and it would be easy to liquid-solids separation. The aeration after electrolytic procedure was performed for two hours and it was sufficient solution for additional removal of organics and neutralization of pH value.
引用
收藏
页码:1522 / 1536
页数:15
相关论文
共 50 条
  • [11] APPLICATION OF COMBINED CHEMICAL COAGULATION AND ELECTRO-COAGULATION PROCESS FOR CARWASH WASTEWATER TREATMENT
    Bazrafshan, Edris
    Mostafapoor, Ferdos Kord
    Soori, Mohammad Mahdi
    Mahvi, Amir Hossein
    FRESENIUS ENVIRONMENTAL BULLETIN, 2012, 21 (9A): : 2694 - 2701
  • [12] Membrane Technology for Laundry Wastewater Treatment: Recent Progresses and Future Outlook
    Zakaria, Nur Alyaa Syfina
    Goh, Pei Sean
    Lau, Woei Jye
    Ismail, Ahmad Fauzi
    Samavati, Zahra
    SEPARATION AND PURIFICATION REVIEWS, 2025,
  • [13] Ecotoxicological Evaluation and Treatment of a Denim-Laundry Wastewater
    Edith Mendez-Hernandez, Jazmin
    Ramirez-Vives, Florina
    Socorro Sobrino-Figueroa, Alma
    Misael Garza-Lopez, Paul
    Loera, Octavio
    WATER AIR AND SOIL POLLUTION, 2022, 233 (01)
  • [14] Electrocoagulation/electroflotation as a combined process for the laundry wastewater purification and reuse
    Dimoglo, A.
    Sevim-Elibol, P.
    Dinc, O.
    Gokmen, K.
    Erdogan, H.
    JOURNAL OF WATER PROCESS ENGINEERING, 2019, 31
  • [15] Electrocoagulation/Electroflotation Process for Removal of Organics and Microplastics in Laundry Wastewater
    Akarsu, Ceyhun
    Deniz, Fatma
    CLEAN-SOIL AIR WATER, 2021, 49 (01)
  • [16] Application of nanofiltration and reverse osmosis for treatment and reuse of laundry wastewater
    Yasemin Kaya
    Sedef Dayanir
    Journal of Environmental Health Science and Engineering, 2020, 18 : 699 - 709
  • [17] Treatment of laundry wastewater by biological and electrocoagulation methods
    Ramcharan, Terelle
    Bissessur, Ajay
    WATER SCIENCE AND TECHNOLOGY, 2017, 75 (01) : 84 - 93
  • [18] Laundry wastewater treatment by peroxi-coagulation
    Nayir, Tulin Yilmaz
    Dinc, Ozge
    Kara, Serdar
    Akyol, Abdurrahman
    Dimoglo, Anatoli
    DESALINATION AND WATER TREATMENT, 2020, 182 : 98 - 108
  • [19] Possibilities of application of advanced oxidation - membrane separation system for treatment and reuse of laundry wastewater
    Mozia, Sylwia
    Janus, Magdalena
    Brozek, Piotr
    Bering, Slawomira
    Tarnowski, Krzysztof
    Mazur, Jacek
    Morawski, Antoni Waldemar
    DESALINATION AND WATER TREATMENT, 2017, 64 : 218 - 222
  • [20] Use of iron-bearing waste materials in laundry wastewater treatment
    Arbid, Yara
    Usman, Muhammad
    Luong, N. Tan
    Mathon, Baptiste
    Cedat, Bruno
    Boily, Jean-Francois
    Hanna, Khalil
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 57