Optimized 3D Ultrashort Echo Time Pulmonary MRI

被引:263
作者
Johnson, Kevin M. [1 ]
Fain, Sean B. [1 ,2 ,3 ]
Schiebler, Mark L. [1 ]
Nagle, Scott [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53705 USA
关键词
MRI; lung; ultrashort echo time; radial imaging; K-SPACE TRAJECTORIES; PROJECTION RECONSTRUCTION; LUNG PARENCHYMA; UTE MRI; TRANSVERSE RELAXATION; PHASE-CONTRAST; CINE MRI; IN-VIVO; DENSITY; RESOLUTION;
D O I
10.1002/mrm.24570
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. Methods3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phantom studies. Their effects on lung and airway visualization in five healthy male human subjects (mean age 32 years) were compared qualitatively through blinded ordinal scoring by two cardiothoracic radiologists using a nonparametric Friedman test (P < 0.05). Relative signal difference between endobronchial air and adjacent lung tissue, normalized to nearby vessel, was used as a surrogate for lung tissue signal. Quantitative measures were compared using the paired Student's t-test (P < 0.05). Finally, clinical feasibility was investigated in a patient with interstitial fibrosis. ResultsSimulation and phantom studies showed up to 67% improvement in SNR and reduced blurring for short T2* species using all three optimizations. In vivo images showed decreased artifacts and improved lung tissue and airway visualization both qualitatively and quantitatively. ConclusionThe use of limited field-of-view excitation, variable readout gradients, and radial oversampling significantly improve the technical quality of 3D radial ultrashort echo time lung images. Magn Reson Med 70:1241-1250, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1241 / 1250
页数:10
相关论文
共 63 条
[1]   Single-point ramped imaging with T-1 enhancement (SPRITE) [J].
Balcom, BJ ;
MacGregor, RP ;
Beyea, SD ;
Green, DP ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 123 (01) :131-134
[2]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[3]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[4]   LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING [J].
BERGIN, CJ ;
PAULY, JM ;
MACOVSKI, A .
RADIOLOGY, 1991, 179 (03) :777-781
[5]   Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging [J].
Brau, ACS ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :263-270
[6]   Optimization of RF Excitation to Maximize Signal and T2 Contrast of Tissues With Rapid Transverse Relaxation [J].
Carl, Michael ;
Bydder, Mark ;
Du, Jiang ;
Takahashi, Atsushi ;
Han, Eric .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) :481-490
[7]   Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion [J].
Chen, XJ ;
Hedlund, LW ;
Möller, HE ;
Chawla, MS ;
Maronpot, RR ;
Johnson, GA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (21) :11478-11481
[8]   Simple correction method for k-space trajectory deviations in MRI [J].
Duyn, JH ;
Yang, YH ;
Frank, JA ;
van der Veen, JW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :150-153
[9]   Early Assessment of Pulmonary Inflammation by 19F MRI In Vivo [J].
Ebner, Bernd ;
Behm, Patrick ;
Jacoby, Christoph ;
Burghoff, Sandra ;
French, Brent A. ;
Schrader, Juergen ;
Floegel, Ulrich .
CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (02) :202-U109
[10]   Renal Arteries: Isotropic, High-Spatial-Resolution, Unenhanced MR Angiography with Three-dimensional Radial Phase Contrast [J].
Francois, Christopher J. ;
Lum, Darren P. ;
Johnson, Kevin M. ;
Landgraf, Benjamin R. ;
Bley, Thorsten A. ;
Reeder, Scott B. ;
Schiebler, Mark L. ;
Grist, Thomas M. ;
Wieben, Oliver .
RADIOLOGY, 2011, 258 (01) :254-260