Enantioseparation and determination of asenapine in biological fluid micromatrices by HPLC with diode array detection

被引:25
|
作者
Protti, Michele [1 ]
Vignali, Alice [1 ]
Blanco, Teresa Sanchez [1 ]
Rudge, James [2 ]
Bugamelli, Francesca [1 ]
Ferranti, Anna [1 ]
Mandrioli, Roberto [3 ]
Mercolini, Laura [1 ]
机构
[1] Univ Bologna, Alma Mater Studiorum, Dept Pharm & Biotechnol, Bologna, Italy
[2] Neoteryx LLC, Torrance, CA USA
[3] Univ Bologna, Dept Life Qual Studies, Rimini, Italy
关键词
asenapine; chiral stationary phases; enantioseparation; method validation; volumetric absorptive microsampling; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; MAJOR METABOLITES; HUMAN PLASMA; LC-MS/MS; QUANTIFICATION; MICROEXTRACTION; ANTIPSYCHOTICS; VALIDATION;
D O I
10.1002/jssc.201701315
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Asenapine is a recent drug approved in the European Union for the treatment of bipolar disorder. An original approach has been developed for asenapine analysis in patients treated with the drug, including miniaturized microsampling procedures, separation and quantitation of drug enantiomers. An original enantioselective method based on high-performance liquid chromatography with diode array detection was developed and applied to the determination of asenapine enantiomer levels in innovative haematic samples: four micromatrices have been tested, two based on dried matrix spots (dried blood spots and dried plasma spots) and two based on volumetric absorptive microsampling (from blood and plasma). Chiral separation was achieved on a cellulose-tris(3,5 dimethylphenylcarbamate) column, with a mobile phase containing bicarbonate buffer and acetonitrile. The method was validated with satisfactory results of linearity and precision on all matrices that showed also a significant performance in terms of stability, feasibility and reliability, when compared to fluid plasma sampling, handling and processing. Among micromatrices, both volumetric absorptive microsampling types were superior to dried matrix spots in terms of data reproducibility and correspondence with plasma levels. The bioanalytical approach proposed herein provides for the first time a chiral high-performance liquid chromatographic method for the determination of asenapine enantiomers, coupled to a very effective microsampling strategy.
引用
收藏
页码:1257 / 1265
页数:9
相关论文
共 50 条
  • [31] Micromechanical slit system in HPLC diode-array detection
    Kraiczek, K
    Vuilleumier, R
    IEEE/LEOS 1996 SUMMER TOPICAL MEETINGS - ADVANCED APPLICATIONS OF LASERS IN MATERIALS AND PROCESSING, DIGEST, 1996, : C27 - C28
  • [32] A stability-indicating HPLC assay with diode array detection for the determination of a benzylpenicillin prodrug in aqueous solutions
    Jain, Rohit
    Wu, Zimei
    Tucker, Ian G.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 841 - 846
  • [33] Determination of sulfamethazine and trimethoprim in liquid feed premixes by HPLC and diode array detection, with an analysis of the uncertainty of the results
    Cancho-Grande, B
    García-Falcón, MS
    Rodríguez-Comesaña, M
    Simal-Gándara, J
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (07) : 3145 - 3150
  • [34] Determination of Insulin in Humans with Insulin-Dependent Diabetes Mellitus Patients by HPLC with Diode Array Detection
    Yilmaz, Bilal
    Kadioglu, Yucel
    Capoglu, Ilyas
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (07) : 586 - 590
  • [35] A non-extracting procedure for the determination of meloxicam in plasma samples by HPLC-diode array detection
    Medvedovici, A
    Albu, F
    Georgita, C
    Mircioiu, C
    David, V
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2005, 55 (06): : 326 - 331
  • [36] Development and optimization of the SPE procedure for determination of pharmaceuticals in water samples by HPLC-diode array detection
    Pavlovic, Dragana Mutavdzic
    Babic, Sandra
    Dolar, Davor
    Asperger, Danijela
    Kosutic, Kresimir
    Horvat, Alka J. M.
    Kastelan-Macan, Marija
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (02) : 258 - 267
  • [37] Simultaneous determination of catechins, rutin, and gallic acid in Cistus species extracts by HPLC with diode array detection
    Santagati, Natale Alfredo
    Salerno, Loredana
    Attaguile, Giuseppina
    Savoca, Francesca
    Ronsisvalle, Giuseppe
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (02) : 150 - 156
  • [38] Simultaneous determination of nucleosides, myriocin, and carbohydrates in Cordyceps by HPLC coupled with diode array detection and evaporative light scattering detection
    Wang, Shuang
    Yang, Feng-qing
    Feng, Kun
    Li, De-qiang
    Zhao, Jing
    Li, Shao-ping
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (23-24) : 4069 - 4076
  • [39] Purity determination of peroxisomicine A1 by HPLC with a diode array detector
    Salazar, MD
    De Alba, PLL
    López, AP
    De Torres, NW
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (12) : 1747 - 1760
  • [40] Determination of nine active components in Radix Hedysari and Radix Astragali using capillary HPLC with diode array detection and MS detection
    Zhao, Jing
    Yu, Qing-Tao
    Li, Ping
    Zhou, Peng
    Zhang, Yuan-Jie
    Wang, Wei
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (02) : 255 - 261