COMPARATIVE EVALUATION OF REAL-TIME PCR WITH CONVENTIONAL PCR ASSAY FOR DIAGNOSIS OF BRUCELLOSIS IN RUMINANTS

被引:1
|
作者
Saleem, M. Z. [1 ]
Akhtar, R. [1 ]
Aslam, A. [1 ]
Rashid, M., I [2 ]
Chaudhry, Z., I [1 ]
Shah, B. A. [3 ]
Ahmed, R. [4 ]
Akmal, M. [5 ]
Murtaza, G. [5 ]
机构
[1] Univ Vet & Anim Sci, Dept Pathol, Lahore, Pakistan
[2] Univ Vet & Anim Sci, Dept Parasitol, Lahore, Pakistan
[3] Univ Vet & Anim Sci, Dept Clin Med, Lahore, Pakistan
[4] Cholistan Univ Vet & Anim Sci, Dept Microbiol, Bahawalpur, Pakistan
[5] Livestock Prod Res Inst Bahadurnagar Okara, Livestock & Dairy Dev Dept, Okara, Pakistan
来源
JOURNAL OF ANIMAL AND PLANT SCIENCES-JAPS | 2020年 / 30卷 / 06期
关键词
Brucellosis; B; abortus; melitensis; Buffalo; Cattle; PCR; RBPT; Molecular diagnosis; SINGLE-NUCLEOTIDE POLYMORPHISMS; POLYMERASE-CHAIN-REACTION; AMPLIFICATION LAMP TEST; ABORTUS; MELITENSIS; BOVINE; CATTLE; DISEASES; ANIMALS; BLOOD;
D O I
10.36899/JAPS.2020.6.0159
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Brucellosis is zoonotic and highly infectious disease which not only causes the economic losses in ruminants but also infect the humans. In the present study, we compared the molecular techniques of PCR versions and clinical specimens for the diagnosis of brucellosis in ruminants Blood and serum samples were collected from 692 cattle, 798 buffalo, 471 sheep and 960 goats from two areas; Kasur and Sheikhupura. After serological screening with Rose Bengal antigen, the seropositive serum samples of 73 cattle, 61 buffalo, 91 sheep and 118 goats were subjected to Real-time PCR and Conventional PCR for comparison. Real-time PCR detected significantly (P <= 0.01) more Brucella abortus (66 cattle, 53 buffalo) and Brucella melitensis (59 sheep, 81 goats) in large and small ruminants, respectively in the serum samples of seropositive ruminants than conventional PCR (45 cattle, 37 buffalo, 34 sheep and 47 goats). The Chi-square analysis confirmed significantly (P <= 0.01) more detection of B. abortus (66 cattle, 53 buffalo) and B. melitensis (59 sheep, 81 goats) in serum samples specimens of cattle, buffalo and sheep, goats, respectively than their respective blood samples (48 cattle, 39 buffalo, 44 sheep and 63 goats) in seropositive ruminants. It can be concluded that real-time PCR assay is more sensitive and reliable method for the diagnosis of brucellosis, that serum is the optimal specimen for the diagnosis of brucellosis by Real-time PCR.
引用
收藏
页码:1389 / 1394
页数:6
相关论文
共 50 条
  • [41] Comparison between Conventional and Real-Time PCR Assays for Diagnosis of Visceral Leishmaniasis
    Pereira, Mariana R.
    Rocha-Silva, Fabiana
    Graciele-Melo, Cidiane
    Lafuente, Camila R.
    Magalhaes, Telcia
    Caligiorne, Rachel B.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [42] A real time RT-PCR assay for the specific detection of Peste des petits ruminants virus
    Battena, Carrie A.
    Banyard, Ashley C.
    King, Donald P.
    Henstock, Mark R.
    Edwards, Lorraine
    Sanders, Anna
    Buczkowski, Hubert
    Oura, Chris C. L.
    Barrett, Tom
    JOURNAL OF VIROLOGICAL METHODS, 2011, 171 (02) : 401 - 404
  • [43] Development of real-time PCR assay for the detection of Mycoplasma bovis
    Behera, S.
    Rana, R.
    Gupta, P. K.
    Kumar, D.
    Sonal
    Rekha, V.
    Arun, T. R.
    Jena, D.
    TROPICAL ANIMAL HEALTH AND PRODUCTION, 2018, 50 (04) : 875 - 882
  • [44] Comparative studies of mastitis detection using real-time PCR and conventional bacteriology
    Spohr, Martin
    Breitenwieser, Franziska
    PRAKTISCHE TIERARZT, 2012, 93 (04): : 342 - 350
  • [45] Comparison of the specificity and sensitivity of PCR, nested PCR, and real-time PCR for the diagnosis of histomoniasis
    Hafez, HM
    Hauck, R
    Lüschow, D
    McDougald, L
    AVIAN DISEASES, 2005, 49 (03) : 366 - 370
  • [46] Development of multiplex real-time PCR assay for the detection of Brucella spp., Leptospira spp. and Campylobacter foetus
    Selim, Abdelfattah M.
    Elhaig, Mahmoud M.
    Gaede, Wolfgang
    VETERINARIA ITALIANA, 2014, 50 (04) : 269 - 275
  • [47] New Panfungal Real-Time PCR Assay for Diagnosis of Invasive Fungal Infections
    Valero, Clara
    de la Cruz-Villar, Laura
    Zaragoza, Oscar
    Jose Buitrago, Maria
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (12) : 2910 - 2918
  • [48] Development of a multiplex real-time PCR assay for the rapid diagnosis of neonatal late onset sepsis
    van den Brand, Marre
    Peters, Remco P. H.
    Catsburg, Arnold
    Rubenjan, Anna
    Broeke, Ferdi J.
    van den Dungen, Frank A. M.
    van Weissenbruch, Mirjam M.
    van Furth, A. Marceline
    Koressaar, Triinu
    Remm, Maido
    Savelkoul, Paul H. M.
    Bos, Martine P.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 106 : 8 - 15
  • [49] Evaluation of a Rapid and Completely Automated Real-Time Reverse Transcriptase PCR Assay for Diagnosis of Enteroviral Meningitis
    Nolte, Frederick S.
    Rogers, Beverly B.
    Tang, Yi-Wei
    Oberste, M. Steven
    Robinson, Christine C.
    Kehl, K. Sue
    Rand, Kenneth A.
    Rotbart, Harley A.
    Romero, Jose R.
    Nyquist, Ann-Christine
    Persing, David H.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (02) : 528 - 533
  • [50] Real-time quantitative PCR for toxoplasmosis diagnosis
    Ordinaire, I
    Simon, A
    Fréalle, E
    Soula, F
    Valat, AS
    Rouland, V
    Subtil, D
    Dei-Cas, E
    Camus, D
    Delhaes, L
    ANNALES DE BIOLOGIE CLINIQUE, 2005, 63 (01) : 67 - 73