The Influence of Distance on Radiant Exposure and Degree of Conversion Using Different Light-Emitting-Diode Curing Units

被引:21
作者
Al-Zain, A. O. [1 ]
Eckert, G. J. [2 ]
Platt, J. A. [3 ]
机构
[1] King Abdulaziz Univ, Restorat Dent Dept, Fac Dent, Jeddah, Saudi Arabia
[2] Indiana Univ, Sch Med, Div Biostat, Indianapolis, IN USA
[3] Indiana Univ, Dept Biomed & Appl Sci, Indianapolis, IN 46204 USA
关键词
RESIN-BASED COMPOSITES; CROSS-LINK DENSITY; LED LIGHT; RECIPROCITY LAW; CURE; POLYMERIZATION; TRANSMITTANCE; DEPTH; MICROHARDNESS; MAINTENANCE;
D O I
10.2341/18-004-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the influence of curing distance on the degree of conversion (DC) of a resin-based composite (RBC) when similar radiant exposure was achieved using six different light-curing units (LCUs) and to explore the correlation among irradiance, radiant exposure, and DC. Methods and Materials: A managing accurate resin curing-resin calibrator system was used to collect irradiance data for both top and bottom specimen surfaces with a curing distance of 2 mm and 8 mm while targeting a consistent top surface radiant exposure. Square nanohybrid-dual-photoinitiator RBC specimens (5 x 5 X 2 mm) were cured at each distance (n=6/LCU/distance). Irradiance and DC (micro-Raman spectroscopy) were determined for the top and bottom surfaces. The effect of distance and LCU on irradiance, radiant exposure, and DC as well as their linear associations were analyzed using analysis of variance and Pearson correlation coefficients, respectively (alpha=0.05). Results: While maintaining a similar radiant exposure, each LCU exhibited distinctive patterns in decreased irradiance and increased curing time. No significant differences in DC values (63.21%-70.28%) were observed between the 2- and 8-mm distances, except for a multiple-emission peak LCU. Significant differences in DC were detected among the LCUs. As expected, irradiance and radiant exposure were significantly lower on the bottom surfaces. However, a strong correlation between irradiance and radiant exposure did not necessarily result in a strong correlation with DC. Conclusions: The RBC exhibited DC values >63% when the top surface radiant exposure was maintained, although the same values were not reached for all lights. A moderatestrong correlation existed among irradiance, radiant exposure, and DC.
引用
收藏
页码:E133 / E144
页数:12
相关论文
共 50 条
  • [11] Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites
    Durner, Juergen
    Obermaier, Julia
    Draenert, Miriam
    Ilie, Nicoleta
    [J]. DENTAL MATERIALS, 2012, 28 (11) : 46 - 53
  • [12] Effect of mold diameter on the depth of cure of a resin-based composite material
    Erickson, Robert L.
    Barkmeier, Wayne W.
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2017, 125 (01) : 88 - 92
  • [13] Variation in composite degree of conversion and microflexural strength for different curing light and surface location
    Eshmawi, Yousef T.
    Al-Zain, Afnan O.
    Eckert, George J.
    Platt, Jeffrey A.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2018, 149 (10) : 893 - 902
  • [14] Felix CA, 2003, J ADHES DENT, V5, P283
  • [15] Exposure reciprocity law in photopolymerization of multi-functional acrylates and methacrylates
    Feng, Li
    Suh, Byoung I.
    [J]. MACROMOLECULAR CHEMISTRY AND PHYSICS, 2007, 208 (03) : 295 - 306
  • [16] Wear and marginal breakdown of composites with various degrees of cure
    Ferracane, JL
    Mitchem, JC
    Condon, JR
    Todd, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 (08) : 1508 - 1516
  • [17] ELUTION OF LEACHABLE COMPONENTS FROM COMPOSITES
    FERRACANE, JL
    [J]. JOURNAL OF ORAL REHABILITATION, 1994, 21 (04) : 441 - 452
  • [18] Effect of photoactivation protocol and radiant exposure on monomer conversion and flexural strength of a resin composite after water and ethanol storage
    Goncalves, F.
    Calheiros, F. C.
    Witzel, M. F.
    Kawano, Y.
    Braga, R. R.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 82B (01) : 89 - 92
  • [19] Effect of the irradiance distribution from light curing units on the local micro-hardness of the surface of dental resins
    Haenel, Thomas
    Hausnerova, Berenika
    Steinhaus, Johannes
    Price, Richard B. T.
    Sullivan, Braden
    Moeginger, Bernhard
    [J]. DENTAL MATERIALS, 2015, 31 (02) : 93 - 104
  • [20] Impact of light transmittance mode on polymerisation kinetics in bulk-fill resin-based composites
    Ilie, Nicoleta
    [J]. JOURNAL OF DENTISTRY, 2017, 63 : 51 - 59