The Influence of Distance on Radiant Exposure and Degree of Conversion Using Different Light-Emitting-Diode Curing Units

被引:21
作者
Al-Zain, A. O. [1 ]
Eckert, G. J. [2 ]
Platt, J. A. [3 ]
机构
[1] King Abdulaziz Univ, Restorat Dent Dept, Fac Dent, Jeddah, Saudi Arabia
[2] Indiana Univ, Sch Med, Div Biostat, Indianapolis, IN USA
[3] Indiana Univ, Dept Biomed & Appl Sci, Indianapolis, IN 46204 USA
关键词
RESIN-BASED COMPOSITES; CROSS-LINK DENSITY; LED LIGHT; RECIPROCITY LAW; CURE; POLYMERIZATION; TRANSMITTANCE; DEPTH; MICROHARDNESS; MAINTENANCE;
D O I
10.2341/18-004-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the influence of curing distance on the degree of conversion (DC) of a resin-based composite (RBC) when similar radiant exposure was achieved using six different light-curing units (LCUs) and to explore the correlation among irradiance, radiant exposure, and DC. Methods and Materials: A managing accurate resin curing-resin calibrator system was used to collect irradiance data for both top and bottom specimen surfaces with a curing distance of 2 mm and 8 mm while targeting a consistent top surface radiant exposure. Square nanohybrid-dual-photoinitiator RBC specimens (5 x 5 X 2 mm) were cured at each distance (n=6/LCU/distance). Irradiance and DC (micro-Raman spectroscopy) were determined for the top and bottom surfaces. The effect of distance and LCU on irradiance, radiant exposure, and DC as well as their linear associations were analyzed using analysis of variance and Pearson correlation coefficients, respectively (alpha=0.05). Results: While maintaining a similar radiant exposure, each LCU exhibited distinctive patterns in decreased irradiance and increased curing time. No significant differences in DC values (63.21%-70.28%) were observed between the 2- and 8-mm distances, except for a multiple-emission peak LCU. Significant differences in DC were detected among the LCUs. As expected, irradiance and radiant exposure were significantly lower on the bottom surfaces. However, a strong correlation between irradiance and radiant exposure did not necessarily result in a strong correlation with DC. Conclusions: The RBC exhibited DC values >63% when the top surface radiant exposure was maintained, although the same values were not reached for all lights. A moderatestrong correlation existed among irradiance, radiant exposure, and DC.
引用
收藏
页码:E133 / E144
页数:12
相关论文
共 50 条
  • [1] Degree of conversion and cross-link density within a resin-matrix composite
    Al-Zain, Afnan O.
    Eckert, George J.
    Lukic, Henry
    Megremis, Spiro J.
    Platt, Jeffrey A.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (04) : 1496 - 1504
  • [2] AlShaafi MM, 2017, SAUDI DENT J, V29, P48, DOI 10.1016/j.sdentj.2017.01.002
  • [3] Stability of the Light Output, Oral Cavity Tip Accessibility in Posterior Region and Emission Spectrum of Light-Curing Units
    Andre, C. B.
    Nima, G.
    Sebold, M.
    Giannini, M.
    Price, R. B.
    [J]. OPERATIVE DENTISTRY, 2018, 43 (04) : 398 - 407
  • [4] Light transmittance characteristics of light-cured composite resins
    Arikawa, H
    Fujii, K
    Kanie, T
    Inoue, K
    [J]. DENTAL MATERIALS, 1998, 14 (06) : 405 - 411
  • [5] Changes in irradiance and energy density in relation to different curing distances
    Beolchi, Rafael Silva
    Moura-Netto, Cacio
    Palo, Renato Miotto
    Gomes Torres, Carlos Rocha
    Pelissier, Bruno
    [J]. BRAZILIAN ORAL RESEARCH, 2015, 29 (01): : 1 - 7
  • [6] Effect of different photo-activation methods on push out force, hardness and cross-link density of resin composite restorations
    Brandt, William Cunha
    de Moraes, Rafael Ratto
    Correr-Sobrinho, Lourenco
    Coelho Sinhoreti, Mario Alexandre
    Consani, Simonides
    [J]. DENTAL MATERIALS, 2008, 24 (06) : 846 - 850
  • [7] Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites
    Bucuta, Stefan
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (08) : 1991 - 2000
  • [8] The influence of tip geometry and distance on light-curing efficacy
    Corciolani, G.
    Vichi, A.
    Davidson, C. L.
    Ferrari, M.
    [J]. OPERATIVE DENTISTRY, 2008, 33 (03) : 325 - 331
  • [9] Volume contraction in photocured dental resins: The shrinkage-conversion relationship revisited
    Dewaele, M
    Truffier-Boutry, D
    Devaux, J
    Leloup, G
    [J]. DENTAL MATERIALS, 2006, 22 (04) : 359 - 365
  • [10] Influence of curing protocol on selected properties of light-curing polymers: Degree of conversion, volume contraction, elastic modulus, and glass transition temperature
    Dewaele, Magali
    Asmussen, Erik
    Peutzfeldt, Anne
    Munksgaard, E. Christian
    Benetti, Ana R.
    Finne, Gauthier
    Leloup, Gaetane
    Devaux, Jacques
    [J]. DENTAL MATERIALS, 2009, 25 (12) : 1576 - 1584