An improved configuration of low-temperature pre-drying using waste heat integrated in an air-cooled lignite fired power plant

被引:50
|
作者
Xu, Cheng [1 ,2 ]
Xu, Gang [1 ,2 ]
Yang, Yongping [1 ]
Zhao, Shifei [1 ]
Zhang, Kai [1 ]
Zhang, Dongke [2 ]
机构
[1] North China Elect Power Univ, Beijing Key Lab Emiss Surveillance & Control Ther, Beijing 102206, Peoples R China
[2] Univ Western Australia, Ctr Energy M473, Crawley, WA 6009, Australia
关键词
Air-cooled power plant; Economic analysis; Lignite pre-drying; Thermodynamic analysis; Waste heat recovery; ECONOMIC-ANALYSIS; COAL; TECHNOLOGY; EMISSIONS; ENERGY; SYSTEM; CO2;
D O I
10.1016/j.applthermaleng.2015.06.101
中图分类号
O414.1 [热力学];
学科分类号
摘要
An improved low-temperature lignite pre-drying configuration using waste heat integrated in an air-cooled lignite fired power plant was proposed and examined in this study. In the proposed configuration, a portion of the steam exhaust from the low-pressure turbines condenses and then releases the latent heat in tubes embedded in a fluidized bed lignite dryer to heat the raw lignite while the warmed air from the air-cooled condensers is utilized as the fluidizing and drying medium, passing through the fluidized dryer. Through employing the proposed drying system, a part of the rejected heat of the aircooled condensers could be recovered efficiently and beneficially utilized to dry and upgrade the raw lignite, thus leading to an improvement in the overall energy efficiency of the power plant. The results of a detailed thermodynamic analysis showed that, for a typical 600 MW air-cooled lignite fired power plant using the proposed configuration, the net power plant efficiency could be improved by 13 percent points with additional net power output of 19.7 MWe as compared to the reference plant without lignite pre-drying. The levelised cost of electricity (LCOE) is reduced from $47.3/MWh in the reference power plant to $45.1/MWh in the proposed power plant. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 22 条
  • [1] An improved configuration of lignite pre-drying using a supplementary steam cycle in a lignite fired supercritical power plant
    Xu, Cheng
    Xu, Gang
    Zhao, Shifei
    Zhou, Luyao
    Yang, Yongping
    Zhang, Dongke
    APPLIED ENERGY, 2015, 160 : 882 - 891
  • [2] A novel lignite pre-drying system integrated with flue gas waste heat recovery at lignite-fired power plants
    Yan, Min
    Ma, Chunyuan
    Shen, Qiuwan
    Song, Zhanlong
    Chang, Jingcai
    APPLIED THERMAL ENGINEERING, 2019, 150 : 200 - 209
  • [3] A novel lignite pre-drying system with low-grade heat integration for modern lignite power plants
    Xu, Cheng
    Xu, Gang
    Han, Yu
    Liang, Feifei
    Fang, Yaxiong
    Yang, Yongping
    CHINESE SCIENCE BULLETIN, 2014, 59 (33): : 4426 - 4435
  • [4] An integrated lignite pre-drying system using steam bleeds and exhaust flue gas in a 600 MW power plant
    Xu, Gang
    Dong, Wei
    Xu, Cheng
    Liu, Qi
    Yang, Yongping
    APPLIED THERMAL ENGINEERING, 2016, 107 : 1145 - 1157
  • [5] A novel lignite pre-drying system incorporating a supplementary steam cycle integrated with a lignite fired supercritical power plant
    Xu, Cheng
    Xu, Gang
    Fang, Yaxiong
    Zhou, Luyao
    Yang, Yongping
    Zhang, Dongke
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 1360 - 1363
  • [6] A novel solar energy integrated low-rank coal fired power generation using coal pre-drying and an absorption heat pump
    Xu, Cheng
    Bai, Pu
    Xin, Tuantuan
    Hu, Yue
    Xu, Gang
    Yang, Yongping
    APPLIED ENERGY, 2017, 200 : 170 - 179
  • [7] An efficient solar/lignite hybrid power generation system based on solar-driven waste heat recovery and energy cascade utilization in lignite pre-drying
    Han, Yu
    Sun, Yingying
    Wu, Junjie
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [8] Thermodynamic analysis of pre-drying methods for pre-dried lignite-fired power plant
    Liu, Ming
    Yan, JunJie
    Chong, DaoTong
    Liu, JiPing
    Wang, JinShi
    ENERGY, 2013, 49 : 107 - 118
  • [9] Thermodynamic analysis and economic evaluation of a 1000 MW bituminous coal fired power plant incorporating low-temperature pre-drying (LTPD)
    Xu, Cheng
    Xu, Gang
    Zhu, Mingming
    Dong, Wei
    Zhang, Yang
    Yang, Yongping
    Zhang, Dongke
    APPLIED THERMAL ENGINEERING, 2016, 96 : 613 - 622
  • [10] Thermo-economic analysis of an efficient lignite-fired power system integrated with flue gas fan mill pre-drying
    Han, X.
    Wang, J.
    Liu, M.
    Karellas, S.
    Yan, J.
    IDS'2018: 21ST INTERNATIONAL DRYING SYMPOSIUM, 2018, : 261 - 268