Independent Component Analysis to Remove ECG interference from Single Channel Electromyographic Signal

被引:0
作者
Costa, Jose D., Jr. [1 ]
Seixas, Jose M. [2 ]
Miranda de Sa, Antonio M. F. L. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Biomed Engn Program, POB 68510, BR-21941972 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Dept Elect Engn, BR-21941972 Rio De Janeiro, Brazil
来源
2013 ISSNIP BIOSIGNALS AND BIOROBOTICS CONFERENCE (BRC) | 2013年
关键词
DIAPHRAGMATIC EMG; CONTAMINATION; CANCELLATION;
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The electromyogram (EMG) is the signal reflecting the electrical activity from the skeletal muscular tissue and the electrocardiogram (ECG) is signal resulting from the electrical activity of the heart. Trunk EMG signals are often contaminated by the ECG. The ECG removal is a difficult task because there is a spectral overlapping between both ECG and EMG signals. In this work, the ECG interference was attenuated by using independent component analysis (ICA). In order to do that, the contaminated EMG was used together with a low-pass filtered version of it as input to the ICA algorithm. The proposed method was effective in removing the ECG from EMG signals, for both simulated and real signals.
引用
收藏
页码:186 / 190
页数:5
相关论文
共 22 条
[1]   ADAPTIVE CANCELLATION TECHNIQUE IN PROCESSING MYOELECTRIC ACTIVITY OF RESPIRATORY MUSCLES [J].
AKKIRAJU, P ;
REDDY, DC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :652-655
[2]   Trunk muscle onset detection technique for EMG signals with ECG artefact [J].
Allison, GT .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (03) :209-216
[3]  
Borschbach M, 2007, ELE COM ENG, P146
[4]   The interpretation of abdominal wall muscle recruitment strategies change when the electrocardiogram (ECG) is removed from the electromyogram (EMG) [J].
Butler, Heather L. ;
Newell, Robyn ;
Hubley-Kozey, Cheryl L. ;
Kozey, John W. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (02) :E102-E113
[5]   Source separation using single channel ICA [J].
Davies, M. E. ;
James, C. J. .
SIGNAL PROCESSING, 2007, 87 (08) :1819-1832
[6]   New aspects to event-synchronous cancellation of ECG interference: An application of the method in diaphragmatic EMG signals [J].
Deng, YC ;
Wolf, W ;
Schnell, R ;
Appel, U .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (09) :1177-1184
[7]   Elimination of electrocardiogram contamination from electromyogram signals: An evaluation of currently used removal techniques [J].
Drake, JDM ;
Callaghan, JP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2006, 16 (02) :175-187
[8]   Effect of electrocardiographic contamination on surface electromyography assessment of back muscles [J].
Hu, Yong ;
Mak, Joseph N. F. ;
Luk, Keith D. K. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (01) :145-156
[9]   Fast and robust fixed-point algorithms for independent component analysis [J].
Hyvärinen, A .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1999, 10 (03) :626-634
[10]   Estimating overcomplete independent component bases for image windows [J].
Hyvärinen, A ;
Inki, M .