High through-put and highly sensitive liquid chromatography-tandem mass spectrometry separations of essential amino acids using active flow technology chromatography columns

被引:18
作者
Kocic, D. [1 ]
Pereira, L. [2 ]
Foley, D. [2 ]
Edge, T. [2 ]
Mosely, J. A. [3 ]
Ritchie, H. [2 ]
Conlan, X. A. [4 ]
Shalliker, R. A. [1 ]
机构
[1] Univ Western Sydney Parramatta, Australian Ctr Res Separat Sci ACROSS, Sch Sci & Hlth, Sydney, NSW, Australia
[2] Thermo Fisher Sci, Runcorn, Cheshire, England
[3] Univ Durham, Dept Chem, Durham DH1 3LE, England
[4] Deakin Univ, Ctr Chem & Biotechnol, Sch Life & Environm Sci, Geelong, Vic 3217, Australia
关键词
HPLC-MS/MS; Active flow technology; Curtain flow; Mass spectrometry;
D O I
10.1016/j.chroma.2013.07.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A preliminary investigation was undertaken to assess the performance of a new chromatography column technology in applications involving liquid chromatography coupled to mass spectrometry. The new column design allows mobile phase and solute to be extracted from the radial central region of the column, which reduces the solvent load to the mass spectrometer and improves separation efficiency. Effectively the column functions as a 'wall-less' column. The advantages of this design is that the analysis through-put can be increased by a factor of five, while at the same time there is a reduction in baseline noise, which results in an increase in the signal to noise response by up to 10-fold in comparison to standard columns with the same internal diameter and approaching 66-fold in comparison to standard' columns with the same virtual internal diameter. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 7 条
  • [1] Enhanced separation performance using a new column technology: Parallel segmented outlet flow
    Camenzuli, Michelle
    Ritchie, Harald J.
    Ladine, James R.
    Shalliker, R. Andrew
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1232 : 47 - 51
  • [2] The design of a new concept chromatography column
    Camenzuli, Michelle
    Ritchie, Harald J.
    Ladine, James R.
    Shalliker, R. Andrew
    [J]. ANALYST, 2011, 136 (24) : 5127 - 5130
  • [3] Curtain flow chromatography ('the infinite diameter column') with automated injection and high sample through-put: The results of an inter-laboratory study
    Foley, D.
    Pereira, L.
    Camenzuli, M.
    Edge, T.
    Ritchie, H.
    Shalliker, R. A.
    [J]. MICROCHEMICAL JOURNAL, 2013, 110 : 127 - 132
  • [4] Kinetic investigation of the relationship between the efficiency of columns and their diameter
    Gritti, Fabrice
    Guiochon, Georges
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (12) : 1592 - 1602
  • [5] INTERACTION OF RADIAL AND AXIAL-DISPERSION IN LIQUID-CHROMATOGRAPHY IN RELATION TO INFINITE DIAMETER EFFECT
    KNOX, JH
    LAIRD, GR
    RAVEN, PA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7): : 129 - 145
  • [6] Parallel segmented flow chromatography columns: Conventional analytical scale column formats presenting as a 'virtual' narrow bore column
    Shalliker, R. A.
    Camenzuli, M.
    Pereira, L.
    Ritchie, H. J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1262 : 64 - 69
  • [7] Physical evidence of two wall effects in liquid chromatography
    Shalliker, RA
    Broyles, BS
    Guiochon, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 888 (1-2) : 1 - 12