Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization

被引:5
作者
Nakaura, Takeshi [1 ]
Kidoh, Masafumi [1 ]
Sakaino, Naritsugu [2 ]
Nakamura, Shota [2 ]
Nozaki, Toshimitsu [2 ]
Izumi, Akari [1 ]
Harada, Kazunori [3 ]
Yamashita, Yasuyuki [4 ]
机构
[1] Amakusa Med Ctr, Kumamoto 8630046, Japan
[2] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto 8630046, Japan
[3] Amakusa Med Ctr, Dept Surg, Kumamoto 8630046, Japan
[4] Kumamoto Univ, Dept Diagnost Radiol, Grad Sch Med, Kumamoto, Japan
关键词
MDCT; Low kilo voltage; Image quality; Radiation dose; LOW-TUBE VOLTAGE; SPIRAL COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CORONARY-ANGIOGRAPHY; LOW-KILOVOLTAGE; ABDOMINAL CT; CANCER-RISKS; SETTINGS; EXPOSURE; IMPACT;
D O I
10.1007/s10554-013-0214-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the radiation dose and image quality of 100 kVp cardiac CT, and the effects of display setting optimization. We randomly assigned 100 patients undergoing cardiac CT to one of following two protocols. Fifty patients underwent our conventional protocol with 120 kVp, and the other 50 patients underwent our low radiation dose protocol with 100 kVp. We compared effective dose (ED); CT number, image noise, and contrast noise ratio (CNR) of ascending aorta at 120 and 100 kVp protocol. We also performed quantitative analysis and qualitative analysis for bitmap image of 120, 100 kVp, and display preset optimization for 100 kVp images. The estimated ED was 48 % lower with the 100 kVp protocol than the 120 kVp protocol (2.8 vs. 5.5 mSv, p < 0.01). There is no significant difference in the CNR between 100 and 120 kVp protocol (18.5 +/- A 3.6 vs. 18.6 +/- A 3.8, p = 0.84). Display preset optimization significantly improved image quality of 100 kVp cardiac CT, and there is no significant difference in qualitative analysis and quantitative analysis between 100 kVp scan with optimized display preset and 120 kVp scan (p > 0.05). The 100 kVp scanning with optimized display preset offers almost same image quality at cardiac CT of thin adults under 48 % decreased radiation dose.
引用
收藏
页码:1381 / 1389
页数:9
相关论文
共 29 条
[1]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[2]   Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose Results of the PROTECTION I Study [J].
Bischoff, Bernhard ;
Hein, Franziska ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Martinoff, Stefan ;
Schoemig, Albert ;
Hausleiter, Joerg .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :940-946
[3]  
Bongartz G., 2004, European guidelines for multislice computed tomography
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[6]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[7]   Multi-detector row CT angiography of the brain at various kilovoltage settings [J].
Ertl-Wagner, BB ;
Hoffmann, RT ;
Bruning, R ;
Herrmann, K ;
Snyder, B ;
Blume, JD ;
Reiser, MF .
RADIOLOGY, 2004, 231 (02) :528-535
[8]   Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study [J].
Funama, Y ;
Awai, K ;
Nakayama, Y ;
Kakei, K ;
Nagasue, N ;
Shimamura, M ;
Sato, N ;
Sultana, S ;
Morishita, S ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :905-910
[9]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[10]   Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT Angiography Results of the PROTECTION II Trial [J].
Hausleiter, Jorg ;
Martinoff, Stefan ;
Hadamitzky, Martin ;
Martuscelli, Eugenio ;
Pschierer, Iris ;
Feuchtner, Gudrun M. ;
Catalan-Sanz, Paz ;
Czermak, Benedikt ;
Meyer, Tanja S. ;
Hein, Franziska ;
Bischoff, Bernhard ;
Kuse, Miriam ;
Schomig, Albert ;
Achenbach, Stephan .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (11) :1113-1123