Can Continuous Glucose Monitoring Systems Predict Glycemia?

被引:0
|
作者
Gonzalez, Concepcion
Maury, Elisa
Barcos, Isabelle
Gin, Henri
Rigalleau, Vincent [1 ]
机构
[1] CHU Bordeaux, F-33600 Pessac, France
关键词
TYPE-1;
D O I
10.1089/dia.2012.0130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We investigated whether the arrow on a continuous glucose monitoring system (CGMS) screen predicts the course of the capillary glucose level 15 min later. Subjects and Methods: Twenty-three patients with type 1 diabetes (age, 40 +/- 13 years; diabetes duration, 19 +/- 12 years; hemoglobin A1c, 8.5 +/- 1.5%) admitted for education in the use of a CGMS performed 242 observations: the arrow was noted at time 0, and the interstitial and capillary glucose levels were noted at time 0 and 15 min later. Results: The capillary glucose courses were -15 +/- 28 mg/dL after a descending arrow (n = 55), + 1 +/- 23 mg/dL after a stable arrow (n = 147) (P < 0.001 vs. descending), and + 2 +/- 23 mg/dL after an ascending arrow (n = 40) (P < 0.01 vs. descending), with similar findings for the 67 observations after an interstitial glucose level < 100 mg/dL. There were 4.5% grossly erroneous arrows: six descending with later increasing and five ascending with later decreasing capillary glucose. Conclusions: Although there is a large room for improvement, the arrow on the CGMS screen does predict the decline in capillary glucose 15 min later.
引用
收藏
页码:1030 / 1032
页数:3
相关论文
共 50 条
  • [31] Intergenerational Improvements of Continuous Glucose Monitoring Systems in Youth
    Puhr, Sarah
    Calhoun, Peter
    Welsh, John
    Walker, Tomas C.
    Price, David A.
    DIABETES, 2019, 68
  • [32] Translating Continuous Glucose Monitoring Systems: Toys or Tools
    De Block, Christophe
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 157 - 158
  • [33] Continuous glucose monitoring systems in the service of artificial pancreas
    Eigner, Gyorgy
    Sas, Peter Istvan
    Kovacs, Levente
    2014 IEEE 9TH INTERNATIONAL SYMPOSIUM ON APPLIED COMPUTATIONAL INTELLIGENCE AND INFORMATICS (SACI), 2014, : 117 - 122
  • [34] Reality of the use of continuous glucose monitoring systems in Germany
    Heinemann, L.
    Weber, D.
    Kaltheuner, M.
    DIABETES STOFFWECHSEL UND HERZ, 2022, 31 (01): : 9 - 16
  • [35] Continuous glucose monitoring and closed-loop systems
    Hovorka, R
    DIABETIC MEDICINE, 2006, 23 (01) : 1 - 12
  • [36] Continuous glucose monitoring: different systems, different ambitions
    Choleau, C
    Reach, G
    DIABETES & METABOLISM, 2003, 29 (02) : S15 - S20
  • [37] Review of the Long-Term Implantable Senseonics Continuous Glucose Monitoring System and Other Continuous Glucose Monitoring Systems
    Joseph, Jeffrey I.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (01): : 167 - 173
  • [38] Theoretical evaluation of the parameters of glucose metabolism on the basis of continuous glycemia monitoring data using mathematical modeling
    Sveshnikova A.N.
    Panteleev M.A.
    Dreval A.V.
    Shestakova T.P.
    Medvedev O.S.
    Dreval O.A.
    Biophysics, 2017, 62 (5) : 842 - 847
  • [39] THE IMPACT OF CONTINUOUS GLUCOSE MONITORING SYSTEMS ON GLUCOSE CONTROL IN CRITICALLY ILL PATIENTS
    Lu, Meizhu
    Kang, Yan
    Guo, Jun
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [40] Continuous glucose monitoring can benefit patients with type 1 diabetes
    Wise, Jacqui
    BMJ-BRITISH MEDICAL JOURNAL, 2017, 356