A new technique to measure the dynamic contact pressures on the Tibial Plateau

被引:29
作者
Cottrell, Jocelyn M. [1 ]
Scholten, Paul [1 ]
Wanich, Tony [1 ]
Warren, Russell F. [1 ]
Wright, Timothy M. [1 ]
Maher, Suzanne A. [1 ]
机构
[1] Hosp Special Surg, Dept Biomech, New York, NY 10021 USA
关键词
meniscus; knee joint mechanics; dynamic contact mechanics;
D O I
10.1016/j.jbiomech.2008.04.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Studies of the load transfer role of the meniscus have been limited to static experimental and analytical approached. The objective of this study was to develop.-in experimental technique to allow the contact pressure Oil the tibial plateau of cadaveric knees to be measured under dynamic physiological loads. Accordingly, we adapted a load-controlled knee joint simulator to accept a cadaveric sheep knee, programmed the simulator with sheep gait kinematics data, and utilized a pressure sensor array to measure the contact pressure distribution on the lateral tibial plateau during gait. The technique was applied to six sheep knees that were tested intact and after meniscectomy. Meniscectomy resulted in a 267% increase in average contact pressure. a 117% increase in peak contact pressure, and an 80% decrease in contact area. all measured at the point of maximum peak contact stress in the gait cycle. It is envisaged that the experimental model herein developed will allow for the screening of candidate materials prior to more expensive and time-consuming animal models. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2324 / 2329
页数:6
相关论文
共 24 条
[1]   Effect of high tibial flexion osteotomy on cartilage pressure and joint kinematics: a biomechanical study in human cadaveric knees - Winner of the AGA-DonJoy Award 2004 [J].
Agneskirchner, JD ;
Hurschler, C ;
Stukenborg-Colsman, C ;
Imhoff, AB ;
Lobenhoffer, P .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (09) :575-584
[2]   The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee: A biomechanical study [J].
Agneskirchner, Jens Dominik ;
Hurschler, Christof ;
Wrann, Christiane D. ;
Lobenhoffer, Philipp .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (08) :852-861
[3]   Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft - A human cadaveric study [J].
Alhalki, MM ;
Hull, ML ;
Howell, SM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (03) :370-376
[4]   LATE DEGENERATIVE CHANGES AFTER MENISCECTOMY - FACTORS AFFECTING THE KNEE AFTER OPERATION [J].
ALLEN, PR ;
DENHAM, RA ;
SWAN, AV .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :666-671
[5]   Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems [J].
Bachus, Kent N. ;
DeMarco, Alyssa L. ;
Judd, Kyle T. ;
Horwitz, Daniel S. ;
Brodke, Darrel S. .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (05) :483-488
[6]   Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants [J].
Becker, R ;
Wirz, D ;
Wolf, C ;
Göpfert, B ;
Nebelung, W ;
Friederich, N .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (04) :254-260
[7]   A direct comparison of patient and force-controlled simulator total knee replacement kinematics [J].
DesJardins, John D. ;
Banks, Scott A. ;
Benson, Lisa C. ;
Pace, Thomas ;
LaBerge, Martine .
JOURNAL OF BIOMECHANICS, 2007, 40 (15) :3458-3466
[8]   Accuracy of circular contact area measurements with thin-film pressure sensors [J].
Drewmak, Elizabeth I. ;
Crisco, Joseph J. ;
Spenciner, David B. ;
Fleming, Braden C. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2569-2572
[9]   The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: a study in human cadaveric knees [J].
Huang, A ;
Hull, ML ;
Howell, SM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (03) :459-464
[10]  
Kelly BT, 2007, AM J SPORT MED, V35, P43, DOI 10.1177/0363546506292848