Cardiac implantable electronic device-related endocarditis: A 12-year single-centre experience

被引:5
作者
Whitaker, John
Williams, Steven
Arujuna, Aruna
Rinaldi, C. Aldo
Chambers, John
Klein, John L. [1 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Directorate Infect, St Thomas Hosp, London SE1 7EH, England
关键词
Pacemaker; endocarditis; UK; management; PACEMAKER-RELATED ENDOCARDITIS; INFECTIVE ENDOCARDITIS; CLINICAL PRESENTATION; MANAGEMENT;
D O I
10.3109/00365548.2012.701015
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The incidence of cardiac implantable electrical device endocarditis (CIEDE) is increasing, but CIEDE remains a relatively poorly described infection. This case series describes our experience of the condition at a tertiary referral centre in London over a 12-y period. Methods: We identified cases using an endocarditis database containing prospectively collected clinical and microbiological information. We also used data recorded in an electronic database of all cardiac implantable electrical device-related procedures. Results: Thirty cases of CIEDE were treated at our institution during the study period. Presentation was most commonly with fever, and 93% of our patients had positive blood cultures. Vegetations were identified on echocardiography in only 70% of patients, although a transoesophageal echocardiogram (TOE) was performed in only half of the cases. Sixty-seven percent of our cases were defined as definite endocarditis according to the modified Duke criteria for infective endocarditis. Twenty-three patients underwent percutaneous explantation of their infected CIED (including 6 patients with vegetations greater than 10 mm in diameter), while 5 underwent surgical explantation. The overall in-hospital mortality was 17%. Conclusions: Our data confirm the life-threatening nature of CIEDE in a UK population. In addition, our experience suggests that percutaneous extraction of devices with large adherent vegetations may be safe, and that the selective use of TOE may not compromise outcomes. Lastly, we show that the modified Duke criteria do not perform very well with this condition, suggesting a need for specific, validated criteria for diagnosing CIEDE.
引用
收藏
页码:922 / 926
页数:5
相关论文
共 12 条
[1]   Update on Cardiovascular Implantable Electronic Device Infections and Their Management A Scientific Statement From the American Heart Association [J].
Baddour, Larry M. ;
Epstein, Andrew E. ;
Erickson, Christopher C. ;
Knight, Bradley P. ;
Levison, Matthew E. ;
Lockhart, Peter B. ;
Masoudi, Frederick A. ;
Okum, Eric J. ;
Wilson, Walter R. ;
Beerman, Lee B. ;
Bolger, Ann F. ;
Estes, N. A. Mark, III ;
Gewitz, Michael ;
Newburger, Jane W. ;
Schron, Eleanor B. ;
Taubert, Kathryn A. .
CIRCULATION, 2010, 121 (03) :458-477
[2]   Pacemaker infective endocarditis [J].
Cacoub, P ;
Leprince, P ;
Nataf, P ;
Hausfater, P ;
Dorent, R ;
Wechsler, B ;
Bors, V ;
Pavie, A ;
Piette, JC ;
Gandjbakhch, I .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (04) :480-484
[3]   Surgical treatment of pacemaker and defibrillator lead endocarditis -: The impact of electrode lead extraction on outcome [J].
del Río, A ;
Anguera, I ;
Miró, JM ;
Mont, L ;
Fowler, VG ;
Azqueta, M ;
Mestres, CA .
CHEST, 2003, 124 (04) :1451-1459
[4]   Pacemaker related endocarditis - Analysis of seven cases [J].
Erdinler, I ;
Okmen, E ;
Zor, U ;
Zor, A ;
Oguz, E ;
Ketenci, B ;
Akyol, A ;
Aytekin, S ;
Ulufer, T .
JAPANESE HEART JOURNAL, 2002, 43 (05) :475-485
[5]   Systemic infection related to endocarditis on pacemaker leads - Clinical presentation and management [J].
Klug, D ;
Lacroix, D ;
Savoye, C ;
Goullard, L ;
Grandmougin, D ;
Hennequin, JL ;
Kacet, S ;
Lekieffre, J .
CIRCULATION, 1997, 95 (08) :2098-2107
[6]   Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis [J].
Li, JS ;
Sexton, DJ ;
Mick, N ;
Nettles, R ;
Fowler, VG ;
Ryan, T ;
Bashore, T ;
Corey, GR .
CLINICAL INFECTIOUS DISEASES, 2000, 30 (04) :633-638
[7]   The 11th World Survey of Cardiac Pacing and Implantable Cardioverter-Defibrillators: Calendar Year 2009-A World Society of Arrhythmia's Project [J].
Mond, Harry G. ;
Proclemer, Alessandro .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (08) :1013-1027
[8]   Successful treatment of pacemaker related endocarditis with acute embolic stroke without device removal [J].
Moukarbel, GV ;
Tabbarah, ZA ;
Khoury, MY .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2003, 9 (01) :39-42
[9]   Clinical Presentation, Etiology, and Outcome of Infective Endocarditis in the 21st Century [J].
Murdoch, David R. ;
Corey, G. Ralph ;
Hoen, Bruno ;
Miro, Jose M. ;
Fowler, Vance G., Jr. ;
Bayer, Arnold S. ;
Karchmer, Adolf W. ;
Olaison, Lars ;
Pappas, Paul A. ;
Moreillon, Philippe ;
Chambers, Stephen T. ;
Chu, Vivian H. ;
Falco, Vicenc ;
Holland, David J. ;
Jones, Philip ;
Klein, John L. ;
Raymond, Nigel J. ;
Read, Kerry M. ;
Tripodi, Marie Francoise ;
Utili, Riccardo ;
Wang, Andrew ;
Woods, Christopher W. ;
Cabell, Christopher H. .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (05) :463-473
[10]  
Ruiz M, 2006, J HEART VALVE DIS, V15, P122