Monte Carlo simulations for 20 MV X-ray spectrum reconstruction of a linear induction accelerator

被引:6
作者
Wang Yi [1 ]
Li Qin [1 ]
Jiang Xiao-Guo [1 ]
机构
[1] China Acad Engn Phys, Inst Fluid Phys, Mianyang 621900, Peoples R China
关键词
X-ray spectrum reconstruction; Monte Carlo method; filter material; scattering photon; linear induction accelerator; TRANSMISSION DATA; RADIATION;
D O I
10.1088/1674-1137/36/9/012
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
To study the spectrum reconstruction of the 20 MV X-ray generated by the Dragon-I linear induction accelerator, the Monte Carlo method is applied to simulate the attenuations of the X-ray in the attenuators of different thicknesses and thus provide the transmission data. As is known, the spectrum estimation from transmission data is an ill-conditioned problem. The method based on iterative perturbations is employed to derive the X-ray spectra, where initial guesses are used to start the process. This algorithm takes into account not only the minimization of the differences between the measured and the calculated transmissions but also the smoothness feature of the spectrum function. In this work, various filter materials are put to use as the attenuator, and the condition for an accurate and robust solution of the X-ray spectrum calculation is demonstrated. The influences of the scattering photons within different intervals of emergence angle on the X-ray spectrum reconstruction are also analyzed.
引用
收藏
页码:861 / 866
页数:6
相关论文
共 19 条
[1]   ANALYTICAL AND EXPERIMENTAL DOSIMETRY TECHNIQUES FOR CALIBRATING A LOW-ENERGY X-RAY-RADIATION SOURCE [J].
BELLEM, RD ;
CRITCHFIELD, KL ;
PELZL, RM ;
PUGH, RD ;
TALLON, RW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) :2139-2146
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]   Dual-energy X-ray radiography for automatic high-Z material detection [J].
Chen, Gongyin ;
Bennett, Gordon ;
Perticone, David .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) :356-359
[4]  
Deng Jian-jun, 2003, High Power Laser and Particle Beams, V15, P502
[5]   Statistical image reconstruction for polyenergetic X-ray computed tomography [J].
Elbakri, IA ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :89-99
[6]   SIMULATION OF X-RAY SPECTRAL RECONSTRUCTION FROM TRANSMISSION DATA BY DIRECT RESOLUTION OF THE NUMERIC SYSTEM AF=T [J].
FRANCOIS, P ;
CATALA, A ;
SCOUARNEC, C .
MEDICAL PHYSICS, 1993, 20 (06) :1695-1703
[7]   X-ray spectrum unfolding using a regularized truncated SVD method [J].
Gallardo, S ;
Ginestar, D ;
Verdú, G ;
Ródenas, J ;
Puchades, V ;
Villaescusa, JI .
X-RAY SPECTROMETRY, 2006, 35 (01) :63-70
[8]  
Hubbell JH, 1996, 5632 NIST RAD BIOM P
[9]   An indirect method of X-ray spectra measurement by simultaneous attenuations of the scattered beam [J].
Mainardi, Raul T. ;
Bonzi, Edgardo V. .
RADIATION PHYSICS AND CHEMISTRY, 2008, 77 (05) :537-544
[10]   Robust megavoltage x-ray spectra estimation from transmission measurements [J].
Manciu, Marian ;
Manciu, Felicia S. ;
Vulcan, Teodor ;
Nes, Elena ;
Waggener, Robert G. .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2009, 17 (01) :85-99