The elasticity and rigidity of the outer coats of the eye

被引:56
作者
Asejczyk-Widlicka, M. [2 ]
Pierscionek, B. K. [1 ]
机构
[1] Univ Ulster, Dept Biomed Sci, Cromore Rd, Coleraine BT52 1SA, Londonderry, North Ireland
[2] Wroclaw Univ Technol, PL-50370 Wroclaw, Poland
关键词
D O I
10.1136/bjo.2008.140178
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims: The aim of this study was to measure the elastic moduli of the cornea and sclera and the rigidity of the eyeball. Methods: Elastic moduli of the cornea and sclera were measured on 22 fresh intact porcine eyes using the relationship between elasticity and changes in pressure and volume applicable to pressure vessel models. Rigidity was determined from the relationship between changes in volume and intraocular pressure (IOP). Induced volume changes were up to 300 ml and within the physiological range of IOP (12-25 mm Hg). IOP readings taken with a transducer were used in calculations. Tonometric values were taken for comparison. Results: For cornea and sclera, the relationship between circumferential stress and volumetric strain (which defines the elastic modulus) was closely approximated to linear (R-2=0.96), but better fitted with a second order polynomial (R-2=1.00). Elastic moduli ranged from 0.05 to 0.24 MPa and 0.15 to 0.83 MPa for the cornea and sclera, respectively. The mean value of ocular rigidity was found to be 0.0024. The effect of increasing IOP on the average corneal radius of curvature was not statistically significant, but it altered the scleral radius of curvature by 0.07 mm/mmHg. Conclusion: The elasticity of the porcine cornea and sclera could be approximated to constant over the physiological range, but showed a tendency to non-linearity. The modulus of elasticity for the sclera is 3 to 3.5 times that of the cornea. The cornea is more resistant than the sclera to IOP changes within the physiological range.
引用
收藏
页码:1415 / 1418
页数:4
相关论文
共 17 条
[1]   Application of structural analysis to the mechanical behaviour of the cornea [J].
Anderson, K ;
El-Sheikh, A ;
Newson, T .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2004, 1 (01) :3-15
[2]   Fluctuations in intraocular pressure and the potential effect on aberrations of the eye [J].
Asejczyk-Widlicka, M. ;
Pierscionek, B. K. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (08) :1054-1058
[3]  
ASEJCZYKWILDLIC.M, 2008, J BIOMED OPTICS
[4]  
Drexler W, 1998, INVEST OPHTH VIS SCI, V39, P2140
[5]  
Eisenlohr J E, 1962, Br J Ophthalmol, V46, P536, DOI 10.1136/bjo.46.9.536
[6]  
Friedenwald JS., 1937, AM J OPHTHALMOL, V20, P985, DOI [DOI 10.1016/S0002-9394(37)90425-2, 10.1016/S0002-9394(37)90425-2]
[7]  
Fung Y. C., 2013, BIOMECHANICS MECH PR
[8]  
GREENE PR, 1980, AM J OPTOM PHYS OPT, V57, P902
[9]   Thermal and biomechanical parameters of porcine cornea [J].
Kampmeier, J ;
Radt, B ;
Birngruber, R ;
Brinkmann, R .
CORNEA, 2000, 19 (03) :355-363
[10]   RHEOLOGY OF CORNEA - EXPERIMENTAL TECHNIQUES AND RESULTS [J].
NYQUIST, GW .
EXPERIMENTAL EYE RESEARCH, 1968, 7 (02) :183-&