Simulation of personalised haemodynamics by various mounting positions of a prosthetic valve using computational fluid dynamics

被引:6
作者
Bongert, Markus [1 ]
Geller, Marius [2 ]
Pennekamp, Werner [3 ]
Nicolas, Volkmar [3 ]
机构
[1] Univ Appl Sci & Arts Dortmund, Res Ctr BioMed Technol BMT, Dept Mech Engn, Sonnenstr 96, D-44139 Dortmund, Germany
[2] Univ Appl Sci & Arts Dortmund, Ctr Res Biomed Engn, D-44139 Dortmund, Germany
[3] Ruhr Univ Bochum, Univ Hosp Bergmannsheil, Inst Radiol Diagnost Intervent Radiol & Nucl Med, D-44789 Bochum, Germany
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2019年 / 64卷 / 02期
关键词
mounting orientation; MRI; numerical simulation; patient-specific; pre-operative; prosthetic bi-leaflet valve; MECHANICAL AORTIC-VALVE; HEART-VALVES; LEFT-VENTRICLE; TILTING DISC; FLOW; ORIENTATION;
D O I
10.1515/bmt-2017-0092
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diseases of the cardiovascular system account for nearly 42% of all deaths in the European Union. In - Germany, approximately 12,000 patients receive surgical replacement of the aortic valve due to heart valve disease alone each year. A three-dimensional (3D) numerical model based on patient-specific anatomy derived from four-dimensional (4D) magnetic resonance imaging (MRI) data was developed to investigate preoperatively the flow-induced impact of mounting positions of aortic prosthetic valves to select the best orientation for individual patients. Systematic steady-state analysis of blood flow for different rotational mounting positions of the valve is only possible using a virtual patient model. A maximum velocity of 1 m/s was used as an inlet boundary condition, because the opening angle of the valve is at its largest at this velocity. For a comparative serial examination, it is important to define the standardised general requirements to avoid impacts other than the rotated implantation of the prosthetic aortic valve. In this study, a uniform velocity profile at the inlet for the inflow of the aortic valve and the real aortic anatomy were chosen for all simulations. An iterative process, with the weighted parameters flow resistance (1), shear stress (2) and velocity (3), was necessary to determine the best rotated orientation. Blood flow was optimal at a 45 degrees rotation from the standard implantation orientation, which will offer a supply to the coronary arteries.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 36 条
[1]   A transverse isotropic viscoelastic constitutive model for aortic valve tissue [J].
Anssari-Benam, Afshin ;
Bucchi, Andrea ;
Screen, Hazel R. C. ;
Evans, Sam L. .
ROYAL SOCIETY OPEN SCIENCE, 2017, 4 (01)
[2]  
Bongert Markus, 2008, 4th European Conference of the International Federation for Medical and Biological Engineering - ECIFMBE 2008, P2614
[3]  
Bongert M, 2010, HORIZ WORLD CARDIOVA, V2, P249
[4]   Fluid-structure coupled CFD simulation of the left ventricular flow during filling phase [J].
Cheng, YG ;
Oertel, H ;
Schenkel, T .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (05) :567-576
[5]   Evaluation of prosthetic-valved devices by means of numerical simulations [J].
de Tullio, M. D. ;
Pascazio, G. ;
Weltert, L. ;
De Paulis, R. ;
Verzicco, R. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2011, 369 (1945) :2502-2509
[6]  
Destatis, 2015, DEATHS SEL CAUS DEAT
[7]  
Dwyer Harry A, 2009, Interact Cardiovasc Thorac Surg, V9, P301, DOI 10.1510/icvts.2008.200006
[8]  
Eurostat, 2009, HLTH STAT ATL MORT E, P107
[9]  
Fleck E, 2010, DTSCH GESELLSCHAFT K
[10]   Stress analysis in a layered aortic arch model under pulsatile blood flow [J].
Gao, Feng ;
Watanabe, Masahiro ;
Matsuzawa, Teruo .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)