3D Ultrasound versus Computed Tomography for Tumor Volume Measurement Compared to Gross Pathology-A Pilot Study on an Animal Model

被引:5
作者
Makouei, Fatemeh [1 ]
Ewertsen, Caroline [2 ,3 ]
Agander, Tina Klitmoller [3 ,4 ]
Olesen, Mikkel Vestergaard [5 ]
Pakkenberg, Bente [3 ,5 ]
Todsen, Tobias [1 ,3 ,6 ]
机构
[1] Rigshosp, Copenhagen Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg & Audiol, DK-2100 Copenhagen, Denmark
[2] Rigshosp, Copenhagen Univ Hosp, Dept Radiol, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Inst Clin Med, Fac Hlth & Med Sci, DK-2200 Copenhagen, Denmark
[4] Rigshosp, Copenhagen Univ Hosp, Dept Pathol, DK-2100 Copenhagen, Denmark
[5] Bispebjerg Frederiksberg Hosp, Ctr Neurosci & Stereol, Dept Neurol, DK-2400 Copenhagen, Denmark
[6] Copenhagen Acad Med Educ & Simulat, DK-2100 Copenhagen, Denmark
关键词
3D ultrasound imaging; ex vivo volume analysis; computed tomography; animal model; tumor volume; EX-VIVO; MARGINS; CT;
D O I
10.3390/jimaging8120329
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
The margin of the removed tumor in cancer surgery has an important influence on survival. Adjuvant treatments, prognostic complications, and financial costs are required when the pathologist observes a close/positive surgical margin. Ex vivo imaging of resected cancer tissue has been suggested for margin assessment, but traditional cross-sectional imaging is not optimal in a surgical setting. Instead, three-dimensional (3D) ultrasound is a portable, high-resolution, and low-cost method to use in the operation room. In this study, we aimed to investigate the accuracy of 3D ultrasound versus computed tomography (CT) to measure the tumor volume in an animal model compared to gross pathology assessment. The specimen was formalin fixated before systematic slicing. A slice-by-slice area measurement was performed to compare the accuracy of the 3D ultrasound and CT techniques. The tumor volume measured by pathological assessment was 980.2 mm(3). The measured volume using CT was 890.4 +/- 90 mm(3), and the volume using 3D ultrasound was 924.2 +/- 96 mm(3). The correlation coefficient for CT was 0.91 and that for 3D ultrasound was 0.96. Three-dimensional ultrasound is a feasible and accurate modality to measure the tumor volume in an animal model. The accuracy of tumor delineation on CT depends on the soft tissue contrast.
引用
收藏
页数:9
相关论文
共 20 条
[1]  
[Anonymous], 2021, MATLAB
[2]  
[Anonymous], 2007, ParaView Guide, A Parallel Visualization Application
[3]   Pilot study of the potential of 3D ultrasound to measure tonsillar volume and hypertrophy [J].
Chung, Daniel ;
Bandarkar, Anjum ;
Rana, Md Sohel ;
Tabrizi, Pooneh R. ;
Preciado, Diego ;
Jago, James ;
Linguraru, Marius George ;
Reilly, Brian K. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 126
[4]   Application and accuracy of ultrasound-guided resections of tongue cancer [J].
de Koning, Klijs J. ;
van Es, Robert J. J. ;
Klijn, Reinoud J. ;
Breimer, Gerben E. ;
Dankbaar, Jan Willem ;
Braunius, Weibel W. ;
van Cann, Ellen M. ;
Dieleman, Francois J. ;
Rijken, Johannes A. ;
Tijink, Bernard M. ;
de Bree, Remco ;
Noorlag, Rob .
ORAL ONCOLOGY, 2022, 133
[5]   Feasibility study of ultrasound-guided resection of tongue cancer with immediate specimen examination to improve margin control - Comparison with conventional treatment [J].
de Koning, Klijs J. ;
Koppes, Sjors A. ;
de Bree, Remco ;
Dankbaar, Jan Willem ;
Willems, Stefan M. ;
van Es, Robert J. J. ;
Noorlag, Rob .
ORAL ONCOLOGY, 2021, 116
[6]   Ultrasound aids in intraoperative assessment of deep resection margins of squamous cell carcinoma of the tongue [J].
de Koning, S. G. Brouwer ;
Karakullukcu, M. B. ;
Lange, C. A. H. ;
Schreuder, W. H. ;
Karssemakers, L. H. E. ;
Ruers, T. J. M. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2020, 58 (03) :285-290
[7]   Assessment of surgical tumor-free resection margins in fresh squamous-cell carcinoma resection specimens of the tongue using a clinical MRI system [J].
Heidkamp, Jan ;
Weijs, Willem L. J. ;
van Engen-van Grunsven, Adriana C. H. ;
de Laak-de Vries, Ilse ;
Maas, Marnix C. ;
Rovers, Maroeska M. ;
Futterer, Jurgen J. ;
Steens, Stefan C. A. ;
Takes, Robert P. .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2020, 42 (08) :2039-2049
[8]   A Review on Real-Time 3D Ultrasound Imaging Technology [J].
Huang, Qinghua ;
Zeng, Zhaozheng .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[9]   Three-dimensional ultrasound imaging of breast cancer by a realtime intraoperative navigation system [J].
Inoue T. ;
Tamaki Y. ;
Sato Y. ;
Nakamoto M. ;
Tamura S. ;
Tanji Y. ;
Taguchi T. ;
Noguchi S. .
Breast Cancer, 2005, 12 (2) :122-129
[10]   Off-site evaluation of three-dimensional ultrasound for the diagnosis of thyroid nodules: comparison with two-dimensional ultrasound [J].
Kim, Soo Chin ;
Kim, Ji-hoon ;
Choi, Seung Hong ;
Yun, Tae Jin ;
Wi, Jae Yeon ;
Kim, Sun Ah ;
Sun, Hye Young ;
Ryoo, Inseon ;
Park, Sun-Won ;
Sohn, Chul-Ho .
EUROPEAN RADIOLOGY, 2016, 26 (10) :3353-3360