An optimized procedure for boron separation and mass spectrometry analysis for river samples

被引:95
作者
Lemarchand, D [1 ]
Gaillardet, J [1 ]
Göpel, C [1 ]
Manhès, G [1 ]
机构
[1] Univ Paris 07, CNRS UMR 7579, Inst Phys Globe, Lab Geochim Cosmochim, F-75252 Paris 05, France
关键词
boron; isotopes; mass spectrometry; chemical separation; geochemistry;
D O I
10.1016/S0009-2541(01)00329-1
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
An optimized procedure for the separation of boron from natural river samples and an improved mass spectrometry determination of boron isotopic ratio are presented. The chemical procedure, based on the use of the boron-specific resin Amberlite IRA 743, is especially efficient in separating boron from natural organic matter-rich samples like river waters. The properties of Amberlite IRA 743 have been investigated. The two factors important in determining the boron affinity for the resin are: the pH value and the ionic strength of the solution from which B is to be extracted. A logarithmic relationship between B partition coefficients and pH values is found. High ionic strength significantly lowers the fixation of B onto the Amberlite resin. The knowledge of the factors controlling the affinity of the resin Amberlite IRA 743 for boron enables us to design a simple and miniaturized chemical separation procedure characterized by (i) three chromatographic steps using, respectively, 50, 10 and 3 mul of resin, (ii) no evaporation step between each column, and (iii) final separation of boron from residual organic matter by sublimation of boric acid at 75degreesC. Boron isotopic ratios are measured using an improved cesium metaborate technique, with graphite and mannitol. Adequate loading conditions enable us to obtain typical signal intensities of 5 X 10(-12) A for 250 ng of boron. No in-run isotopic fractionation is observed, the external reproducibility for standards processed through the entire chemical procedure, as well as for samples, corresponds to 0.35parts per thousand ( +/-2sigma). According to this precision, a slight, but reproducible isotopic fractionation of 0.4parts per thousand is observed for standards processed through the entire chemical procedure whose origin is discussed, but is still unclear. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:323 / 334
页数:12
相关论文
共 17 条
[1]   BORON ISOTOPE ANALYSIS - A REVIEW [J].
AGGARWAL, JK ;
PALMER, MR .
ANALYST, 1995, 120 (05) :1301-1307
[2]  
Catanzaro E.J, 1970, Boric acid: isotopic and assay standard reference materials
[3]   SEPARATION OF CLOSE SPECIES BY DISPLACEMENT DEVELOPMENT ON ION-EXCHANGERS .1. THEORETICAL EQUATION OF STEADY-STATE PERMUTATION FRONT EXPERIMENTAL VERIFICATION IN CASE OF SEPARATION OF BORON ISOTOPES [J].
CONRARD, P ;
CAUDE, M ;
ROSSET, R .
SEPARATION SCIENCE, 1972, 7 (05) :465-486
[4]   Boron isotopic compositions of corals: Seawater or diagenesis record? [J].
Gaillardet, J ;
Allegre, CJ .
EARTH AND PLANETARY SCIENCE LETTERS, 1995, 136 (3-4) :665-676
[5]   Evaporation and sublimation of boric acid:: Application for boron purification from organic rich solutions [J].
Gaillardet, J ;
Lemarchand, D ;
Göpel, C ;
Manhès, G .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (01) :67-75
[6]   THE ISOTOPIC CONSTITUTION OF TUNGSTEN, SILICON, AND BORON [J].
INGHRAM, MG .
PHYSICAL REVIEW, 1946, 70 (9-10) :653-660
[8]   PRECISE BORON ISOTOPIC ANALYSIS OF AQUEOUS SAMPLES - ION-EXCHANGE EXTRACTION AND MASS-SPECTROMETRY [J].
LEEMAN, WP ;
VOCKE, RD ;
BEARY, ES ;
PAULSEN, PJ .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1991, 55 (12) :3901-3907
[9]   PRECISE BORON ISOTOPIC ANALYSIS OF NATURAL ROCK SAMPLES USING A BORON MANNITOL COMPLEX [J].
NAKAMURA, E ;
ISHIKAWA, T ;
BIRCK, JL ;
ALLEGRE, CJ .
CHEMICAL GEOLOGY, 1992, 94 (03) :193-204
[10]  
Palmer MR, 1996, REV MINERAL, V33, P709