Development Perspective of Bioelectrocatalysis-Based Biosensors

被引:30
作者
Adachi, Taiki [1 ]
Kitazumi, Yuki [1 ]
Shirai, Osamu [1 ]
Kano, Kenji [1 ,2 ]
机构
[1] Kyoto Univ, Grad Sch Agr, Div Appl Life Sci, Sakyo Ku, Kyoto 6068502, Japan
[2] Kyoto Univ, Ctr Adv Sci & Innovat, Uji, Kyoto 6110011, Japan
基金
日本学术振兴会;
关键词
current-potential curve; multi-enzymatic cascades; multianalyte detection; mass-transfer-controlled amperometric response; potentiometric coulometry; DIRECT ELECTRON-TRANSFER; AMPEROMETRIC BIOSENSOR; GLUCOSE BIOSENSORS; ELECTROCHEMICAL BIOSENSORS; CHRONOAMPEROMETRIC CURRENT; CHOLESTEROL ESTERASE; BAND MICROELECTRODES; ENZYME ELECTRODES; CARBON NANOTUBES; ALCOHOL OXIDASE;
D O I
10.3390/s20174826
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bioelectrocatalysis provides the intrinsic catalytic functions of redox enzymes to nonspecific electrode reactions and is the most important and basic concept for electrochemical biosensors. This review starts by describing fundamental characteristics of bioelectrocatalytic reactions in mediated and direct electron transfer types from a theoretical viewpoint and summarizes amperometric biosensors based on multi-enzymatic cascades and for multianalyte detection. The review also introduces prospective aspects of two new concepts of biosensors: mass-transfer-controlled (pseudo)steady-state amperometry at microelectrodes with enhanced enzymatic activity without calibration curves and potentiometric coulometry at enzyme/mediator-immobilized biosensors for absolute determination.
引用
收藏
页码:1 / 21
页数:21
相关论文
共 132 条
[1]   Direct Electron Transfer-Type Bioelectrocatalysis of Redox Enzymes at Nanostructured Electrodes [J].
Adachi, Taiki ;
Kitazumi, Yuki ;
Shirai, Osamu ;
Kano, Kenji .
CATALYSTS, 2020, 10 (02)
[2]   Bioelectrocatalytic performance of D-fructose dehydrogenase [J].
Adachi, Taiki ;
Kaida, Yuya ;
Kitazumi, Yuki ;
Shirai, Osamu ;
Kano, Kenji .
BIOELECTROCHEMISTRY, 2019, 129 :1-9
[3]   A biosensor based on urate oxidase-peroxidase coupled enzyme system for uric acid determination in urine [J].
Akyilmaz, E ;
Sezgintürk, MK ;
Dinçkaya, E .
TALANTA, 2003, 61 (02) :73-79
[4]  
ALBERY WJ, 1990, BIOSENS BIOELECTRON, V5, P367
[5]   Big Data for Health [J].
Andreu-Perez, Javier ;
Poon, Carmen C. Y. ;
Merrifield, Robert D. ;
Wong, Stephen T. C. ;
Yang, Guang-Zhong .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (04) :1193-1208
[6]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[7]  
Antiochia R, 2002, ELECTROANAL, V14, P1256, DOI 10.1002/1521-4109(200210)14:18<1256::AID-ELAN1256>3.0.CO
[8]  
2-N
[9]   Determination of the volume of sweat accumulated in a sweat-patch using sodium and potassium as internal reference [J].
Appenzeller, Brice M. R. ;
Schummer, Claude ;
Rodrigues, Sophie Boura ;
Wennig, Robert .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :333-337
[10]   Reversibility and efficiency in electrocatalytic energy conversion and lessons from enzymes [J].
Armstrong, Fraser A. ;
Hirst, Judy .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (34) :14049-14054