Indirect "one-side" cooling method of a magnetic-alloy-loaded rf cavity

被引:5
作者
Misu, T. [1 ]
Sugiura, A. [1 ]
Hojo, S. [1 ]
Miyahara, N. [1 ]
Kanazawa, M. [1 ]
Iwata, Y. [1 ]
Murakami, T. [1 ]
Yamada, S. [1 ]
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
关键词
D O I
10.1103/PhysRevSTAB.7.122002
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
For magnetic alloy (MA) loaded rf accelerating cavity, we have developed an indirect cooling system, which is effective for retaining its shunt impedance by cooling only one side of the MA cores. Because of its low-Q high-permeability property, MA cores are suitable for constructing untuned broadband accelerating systems. Since these same cores are made of wound thin tape, the key to establishing an untuned broadband cavity with effective indirect cooling method is to suppress the reduction of core impedance when attaching metallic cooling plates to the core and keeping a good thermal contact between them. We have employed indium bonding to thermally connect both cores and cooling plates. Both cooling and endurance tests have demonstrated its successful results.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 4 条
[1]  
Misu T., 2002, P 8 EUR PART ACC C P, P599
[2]  
Ohmori C., 2001, PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268), P888, DOI 10.1109/PAC.2001.986513
[3]  
OHMORI C, 2002, P 8 EUR PART ACC C P, P257
[4]  
YAMADA S, 2001, P 2 AS PART ACC C BE, P829