This paper reports the use of an adsorptive voltammetric technique for Pb(II) determination using cupferron as a selective complexing agent. After accumulation of the complex onto a hanging mercury drop electrode, the electrode potential was scanned with differential pulse modulation and the reduction current of lead was observed at about-0.5V. Under optimum conditions (5x10(-4)molL(-1) cupferron concentration, 0.1molL(-1) acetate buffer (pH 5.5), adsorption at-50mV for 30s) the detection limit was 5.1x10(-10)molL(-1). The relative standard deviation of five measurements for low lead concentration was 3.1%. The accuracy of the method was tested by analysing certified reference material (SPS-WW1 Waste Water). Finally, the method was successfully applied to the determination of Pb(II) in river water samples without any pretreatments.