A simplified technique of esophageal self-expandable metallic stent placement without fluoroscopic and endoscopic guidance for treating esophageal carcinoma

被引:2
作者
Kini, Ratnakar [1 ]
Ramanathan, Sabarinathan
Thangavel, Pugazhendhi
Karunakaran, Premkumar
Mohamed, Kani Shaik
Ananthavadivelu, Murali
机构
[1] Madras Med Coll & Govt Gen Hosp, Dept Med Gastroenterol, Madras, Tamil Nadu, India
关键词
Self-expandable metallic stent; esophageal carcinoma; fluoroscopy; dysphagia; simplified technique; INSERTION; BENIGN; CANCER;
D O I
10.5152/tjg.2018.17112
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Self-expandable metallic stent (SEMS) placement with fluoroscopic guidance is a commonly used technique to relieve obstruction in patients with esophageal carcinoma. However, it has disadvantages such as radiation exposure. SEMS placement with endoscopic guidance also has the disadvantages of causing discomfort to patients as the endoscope and SEMS assembly are simultaneously used and it needs two experts for the procedure to be performed. To overcome these disadvantages, a simplified technique for SEMS placement was developed that does not require fluoroscopic or endoscopic guidance. Our objective was to compare the efficacy and safety of this simplified technique with the conventional SEMS placement method. Materials and Methods: This is a retrospective study including patients with esophageal carcinoma who underwent SEMS placement for the palliation of dysphagia. Results: Sixty-two patients were placed on stents for the palliation for esophageal carcinoma, with 46 patients in the conventional technique group (group A) and 16 in the simplified technique group (group B). The duration of the procedure was considerably lesser in group B than in group A (2 min 53 s vs. 15 min 4 s, p= 0.001). The technical success rate achieved in groups A and B were 97.82% and 100%, respectively. SEMS placement required two experts in the conventional technique whereas the simplified technique required only one expert. Conclusion: The advantages of the simplified technique are as follows: technical ease, cost-effectiveness, no exposure to radiation, requirement of minimal manpower, and less time-consuming; these advantages make it the technique day-care procedure.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 20 条
  • [1] Fatal aortoesophageal fistula bleeding after stenting for a leak post sleeve gastrectomy
    Almadi, Majid A.
    Bamihriz, Fahad
    Aljebreen, Abdulrahman M.
    [J]. WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2013, 5 (12): : 337 - 340
  • [2] An internally covered (lined) self-expanding metal esophageal stent: tissue response in a porcine model
    Baron, Todd H.
    Burgart, Lawrence J.
    Pochron, Nicole L.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2006, 64 (02) : 263 - 267
  • [3] Treatment of Malignant Esophageal Fistulas: Fluoroscopic Placement of Esophageal SEMS, Endoscopically-assisted through Surgical Gastrostomy. A Case Report
    Constantinescu, Gabriel
    Sandru, Vasile
    Ilie, Madalina
    Nedelcu, Cristian
    Tincu, Radu
    Popa, Bogdan
    [J]. JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2016, 25 (02) : 249 - 252
  • [4] Efficacy and safety of a new fully covered self-expandable non-foreshortening metal esophageal stent
    Dua, Kulwinder S.
    Latif, Sahibzada U.
    Yang, Juliana F.
    Fang, Tom C.
    Khan, Abdul
    Oh, Young
    [J]. GASTROINTESTINAL ENDOSCOPY, 2014, 80 (04) : 577 - 585
  • [5] A comparative study between fluoroscopic and endoscopic guidance in palliative esophageal stent placement
    Ferreira, F.
    Bastos, P.
    Ribeiro, A.
    Marques, M.
    Azevedo, F.
    Pereira, P.
    Lopes, S.
    Ramalho, R.
    Macedo, G.
    [J]. DISEASES OF THE ESOPHAGUS, 2012, 25 (07) : 608 - 613
  • [6] Fully versus partially covered self-expandable metal stents in benign esophageal strictures
    Gangloff, A.
    Lecleire, S.
    Di Fiore, A.
    Huet, E.
    Iwanicki-Caron, I.
    Antonietti, M.
    Michel, P.
    [J]. DISEASES OF THE ESOPHAGUS, 2015, 28 (07) : 678 - 683
  • [7] Successful rigid endoscopic removal of an esophageal subtotally covered nitinol stent 11 months after initial placement
    Gouveris, Haralampos T.
    Mann, Wolf J.
    Lippert, Burkard M.
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2009, 266 (06) : 927 - 931
  • [8] Successful management of multiple esophagorespiratory fistulas using two types of stent: Report of a case
    Hamai, Yoichi
    Hihara, Jun
    Emi, Manabu
    Okita, Riki
    Shimizu, Katsuhiko
    Okada, Morihito
    [J]. SURGERY TODAY, 2011, 41 (04) : 560 - 562
  • [9] Silane surface modification for improved bioadhesion of esophageal stents
    Karakoy, Mert
    Gultepe, Evin
    Pandey, Shivendra
    Khashab, Mouen A.
    Gracias, David H.
    [J]. APPLIED SURFACE SCIENCE, 2014, 311 : 684 - 689
  • [10] Esophageal stent fracture: case report and review of the literature
    Khara, Harshit S.
    Diehl, David L.
    Gross, Seth A.
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (10) : 2715 - 2720