Comparison of immunophenotyping by slide-based cytometry and by flow cytometry

被引:31
作者
Gerstner, AOH
Mittag, A
Laffers, W
Dähnert, I
Lenz, D
Bootz, F
Bocsi, J
Tárnok, A
机构
[1] Univ Bonn, Dept Otorhinolaryngol Plast Surg, D-53127 Bonn, Germany
[2] Univ Hosp Leipzig, Ctr Heart, Dept Pediat Cardiol, Leipzig, Germany
[3] Purdue Univ, Sch Vet Med, Dept Basic Med Sci, W Lafayette, IN 47907 USA
关键词
laser scanning cytometry (LSC); flow cytometry; immunophenotyping; triggering; comparative study; resolution parameter;
D O I
10.1016/j.jim.2006.01.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Flow cytometry (FCM) is the gold standard for immunophenotyping of peripheral blood leukocytes (PBLs). Slide-based cytormetry (SBC) systems, for example the laser scanning cytometer (LSC (R), CompuCyte), can give additional information (repeated staining and scanning, morphology). In order to adequately judge the clinical usefulness of LSC for immunophenotyping it is obligatory to compare it with FCM. Aim: The aim of this Study was to systematically compare immunophenotyping by both FCM and LSC methods and to test the correlation of the results. Methods: PBLs were stained with directly labeled monoclonal antibodies with the whole blood staining method. Aliquots of the same paraformaldehyde fixed specimens were analyzed in parallel by a FACScan (BD-Biosciences) using standard protocols and by LSC with different triggers (forward scatter, CD45 FITC, or 7-AAD). For 7-AAD measurements by LSC, slides were additionally fixed with acetone before 7-AAD staining. Results: Calculating the percentage distribution of PBLs obtained by LSC and by FCM showed very good correlation with regression coefficients close to 1.0 for the major Populations and the lymphocyte sub-populations (neutrophils, monocytes, and lymphocytes-, T-helper-, T-cytotoxic-, B-, NK-cells). The best trigger for LSC was 7-AAD. Conclusion: LSC can be recommended for immunophenotyping of PBLs especially in cases where only limited sample volumes are available or where additional analysis of the cells' morphology is important. The detection of rare leukocytes or weak antigens is limited; in these cases appropriate amplification steps for immnofluorescence Should be engaged. (c) 2006 Elsevier B.V.. All rights reserved.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 23 条
  • [1] Scanning fluorescent microscopy analysis is applicable for absolute and relative cell frequency determinations
    Bocsi, J
    Varga, VS
    Molnár, B
    Sipos, F
    Tulassay, Z
    Tárnok, A
    [J]. CYTOMETRY PART A, 2004, 61A (01) : 1 - 8
  • [2] BOROWITZ M, 1998, H42A NCCLS
  • [3] Multiparameter immunophenotypic analysis of fine needle aspiration biopsies and other hematologic specimens by laser scanning cytometry
    Clatch, RJ
    Walloch, JL
    [J]. ACTA CYTOLOGICA, 1997, 41 (01) : 109 - 122
  • [4] Clatch RJ, 1998, CYTOMETRY, V34, P36, DOI 10.1002/(SICI)1097-0320(19980215)34:1<36::AID-CYTO6>3.3.CO
  • [5] 2-0
  • [6] Microdevices for manipulation and accumulation of micro- and nanoparticles by dielectrophoresis
    Dürr, M
    Kentsch, J
    Müller, T
    Schnelle, T
    Stelzle, M
    [J]. ELECTROPHORESIS, 2003, 24 (04) : 722 - 731
  • [7] Distinguishing modes of cell death using the ImageStream® multispectral imaging flow cytometer
    George, TC
    Basiji, DA
    Hall, BE
    Lynch, DH
    Ortyn, WE
    Perry, DJ
    Seo, MJ
    Zimmerman, CA
    Morrissey, PJ
    [J]. CYTOMETRY PART A, 2004, 59A (02): : 237 - 245
  • [8] Immunophenotyping of peripheral blood leukocytes by laser scanning cytometry
    Gerstner, A
    Laffers, W
    Bootz, F
    Tárnok, A
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 246 (1-2) : 175 - 185
  • [9] Near-infrared dyes for six-color immunophenotyping by laser scanning cytometry
    Gerstner, AOH
    Lenz, D
    Laffers, W
    Hoffman, RA
    Steinbrecher, M
    Bootz, F
    Tárnok, A
    [J]. CYTOMETRY, 2002, 48 (03): : 115 - 123
  • [10] Analysis of minimal sample volumes from head and neck cancer by laser scanning cytometry
    Gerstner, AOH
    Machlitt, J
    Laffers, W
    Tárnok, A
    Bootz, F
    [J]. ONKOLOGIE, 2002, 25 (01): : 40 - 46