Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy

被引:24
|
作者
Thibouw, David [1 ]
Truc, Gilles [1 ]
Bertaut, Aurelie [2 ]
Chevalier, Cedric [1 ]
Aubignac, Leone [3 ]
Mirjolet, Celine [1 ]
机构
[1] Georges Francois Leclerc Canc Ctr, Dept Radiat Oncol, Dijon, France
[2] Georges Francois Leclerc Canc Ctr, Dept Stat, Dijon, France
[3] Georges Francois Leclerc Canc Ctr, Dept Med Phys, Dijon, France
关键词
Glioblastoma; Intensity-modulated radiation therapy; 3D conformational radiation therapy; Dosimetric outcomes; Clinical outcomes; HIGH-GRADE GLIOMAS; RADIATION-THERAPY; IMRT; TEMOZOLOMIDE; MULTIFORME;
D O I
10.1007/s11060-017-2735-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We aimed to compare three-dimensional conformal radiotherapy (3D-CRT) with intensity-modulated radiotherapy (IMRT) for the treatment of glioblastoma. Retrospective study of 220 patients with glioblastoma, treated with 3D-CRT or IMRT, with or without surgery. Dosimetric parameters as well as clinical and survival data for the two techniques were analyzed and compared. The median conformity index was 1.53 (range 0-2.69) for 3D-CRT and 1.25 (range 0.97-2.01) for IMRT, p < 10(-4). The median homogeneity index was 0.10 (range 0.03-0.32) for 3D-CRT and 0.07 (range 0.03-0.18) for IMRT, p < 10(-4). There were significantly fewer acute grade 1 and 2 neurological toxicities in the IMRT group especially for edema (1.3 versus 12.4%, p = 0.017), concentration disorders (6.6 versus 19.9%, p = 0.003) and consciousness disorders (2.6 versus 13.2%, p = 0.002) although IMRT patients had a significantly worse pre-treatment neurological status than 3D-CRT patients. Median survival was 16.0 months (range 11.9-17.8) for IMRT and 13.4 months (range 11.7-15.7) for 3D-CRT patients (p = 0.542). IMRT improved target conformity and reduced neurological toxicities for patients with glioblastomas.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [1] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [2] Effect of intensity-modulated radiotherapy versus three-dimensional conformal radiotherapy on clinical outcomes in patients with glioblastoma multiforme
    CHEN Yi-dong
    FENG Jin
    FANG Tong
    YANG Ming
    QIU Xiao-guang
    JIANG Tao
    中华医学杂志(英文版), 2013, 126 (12) : 2320 - 2324
  • [3] Effect of intensity-modulated radiotherapy versus three-dimensional conformal radiotherapy on clinical outcomes in patients with glioblastoma multiforme
    Chen Yi-dong
    Feng Jin
    Fang Tong
    Yang Ming
    Qiu Xiao-guang
    Jiang Tao
    CHINESE MEDICAL JOURNAL, 2013, 126 (12) : 2320 - 2324
  • [4] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [5] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [6] A dosimetric comparison of intensity modulated radiotherapy versus three-dimensional conformal radiotherapy for esophageal carcinoma
    Jiang, Z.
    Zhou, L.
    Jiang, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S268 - S268
  • [7] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL PROTON RADIOTHERAPY, INTENSITY-MODULATED PROTON THERAPY, AND INTENSITY-MODULATED RADIOTHERAPY FOR TREATMENT OF PEDIATRIC CRANIOPHARYNGIOMAS
    Boehling, Nicholas S.
    Grosshans, David R.
    Bluett, Jaques B.
    Palmer, Matthew T.
    Song, Xiaofei
    Amos, Richard A.
    Sahoo, Narayan
    Meyer, Jeffrey J.
    Mahajan, Anita
    Woo, Shiao Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 643 - 652
  • [8] Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
    Liu, Yi-Chi
    Chang, Hung-Ming
    Lin, Hsin-Hon
    Lu, Chia-Chun
    Lai, Lu-Han
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 14
  • [9] Dosimetric Comparisons of Three-dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy in Whole Abdominopelvic Radiotherapy for Gynecologic Malignancy
    Kim, Yong Bae
    Kim, Joo Ho
    Jeong, Kyung Keun
    Seong, Jinsil
    Suh, Chang Ok
    Kim, Gwi Eon
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 369 - 377
  • [10] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196