Development of Methods to Evaluate Several Levels of Uranium Concentrations in Drainage Water Using Total Reflection X-Ray Fluorescence Technique

被引:17
|
作者
Matsuyama, Tsugufumi [1 ,2 ]
Izumoto, Yukie [1 ]
Ishii, Kota [1 ,2 ]
Sakai, Yasuhiro [2 ]
Yoshii, Hiroshi [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Chiba, Japan
[2] Toho Univ, Fac Sci, Dept Phys, Chiba, Japan
来源
FRONTIERS IN CHEMISTRY | 2019年 / 7卷
关键词
uranium; TXRF; drainage water; easy evaporator; Fukushima Daiichi nuclear power plant accident; SOLID-PHASE EXTRACTION; TRACE-ELEMENTS; NATURAL-WATERS; THORIUM; WINES;
D O I
10.3389/fchem.2019.00152
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
As a country's law stipulates the effluent standard uranium concentration in drainage water, the uranium concentration must be determined when drainage water is released from a uranium handling facility, such as the Fukushima Daiichi nuclear power plant. The maximum allowable limit for uranium release at each facility is defined taking into consideration the situation of the facility, such as 1/10 to 1/100 of this effluent standard value. Currently, the uranium concentration of drainage water is commonly determined by alpha-particle spectrometry, in which several liters of drainage water must be evaporated, requiring about half of a day followed by 2-3 h of measurements, due to the low specific radioactivity of uranium. This work proposes a new methodology for the rapid and simple measurement of several levels of uranium in drainage water by a total reflection X-ray fluorescence (TXRF) analysis. Using a portable device for TXRF measurements was found to enable measurements with 1/10 the sensitivity of the effluent standard value by 10 times condensation of the uranium-containing sample solution; a benchtop device is useful to measure uranium concentrations < 1/100 of the effluent standard value. Therefore, the selective usage of methods by a portable and benchtop devices allows for screening and precise evaluation of uranium concentrations in drainage water.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Sample preparation for total reflection X-ray fluorescence analysis using resist pattern technique
    Tsuji, K.
    Yomogita, N.
    Konyuba, Y.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 144 : 68 - 74
  • [22] Simplified Calibration for Total-Reflection X-ray Fluorescence
    Araneda, Axel
    Sanhueza, Vilma
    Bennun, Leonardo
    ANALYTICAL LETTERS, 2016, 49 (11) : 1711 - 1721
  • [23] Rapid determination of platinum plasma concentrations of chemotherapy patients using total reflection X-ray fluorescence
    Greaves, E. D.
    Angeli-Greaves, M.
    Jaehde, U.
    Drescher, A.
    von Bohlen, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (10-11) : 1194 - 1200
  • [24] Total reflection of x-ray fluorescence (TXRF): a mature technique for environmental chemical nanoscale metrology
    Borgese, L.
    Zacco, A.
    Bontempi, E.
    Colombi, P.
    Bertuzzi, R.
    Ferretti, E.
    Tenini, S.
    Depero, L. E.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (08)
  • [25] Total reflection X-ray fluorescence as a fast multielemental technique for human placenta sample analysis
    Margui, E.
    Ricketts, P.
    Fletcher, H.
    Karydas, A. G.
    Migliori, A.
    Leani, J. J.
    Hidalgo, M.
    Queralt, I.
    Voutchkov, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 53 - 59
  • [26] Elemental characterization of nuclear materials using total reflection X-ray fluorescence spectrometry
    Dhara, Sangita
    Misra, N. L.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 116 : 31 - 43
  • [27] Screening of uranium particles by total-reflection X-ray fluorescence spectrometry for safeguards environmental sample analysis
    Esaka, F
    Watanabe, K
    Magara, M
    Hanzawa, Y
    Usuda, S
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04): : 487 - 496
  • [28] A Review of Application of Total Reflection X-ray Fluorescence Spectrometry to Water Analysis
    Pashkova, G. V.
    Revenko, A. G.
    APPLIED SPECTROSCOPY REVIEWS, 2015, 50 (06) : 443 - 472
  • [29] Measurement uncertainty in Total Reflection X-ray Fluorescence
    Floor, G. H.
    Queralt, I.
    Hidalgo, M.
    Margui, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 111 : 30 - 37
  • [30] Determination of technetium by total reflection X-ray fluorescence
    Bermúdez, JI
    Greaves, ED
    Nemeth, P
    Sajo-Bohus, L
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2247 - 2251